STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE

Indonesia is one of the countries located in the Pacific Ring of Fire. Consequently, Indonesia is susceptible to earthquake hazards. One of the devices capable of enhancing structural resilience against earthquakes is the Fluid Viscous Damper (FVD). In this Final Project, three 20-story steel fra...

Full description

Saved in:
Bibliographic Details
Main Author: Agustinus, Ernest
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/82592
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:82592
spelling id-itb.:825922024-07-09T09:59:22ZSTUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE Agustinus, Ernest Teknik sipil Indonesia Final Project viscosity, damping coefficient, time history, displacement, drift, acceleration, hysteretic curve. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/82592 Indonesia is one of the countries located in the Pacific Ring of Fire. Consequently, Indonesia is susceptible to earthquake hazards. One of the devices capable of enhancing structural resilience against earthquakes is the Fluid Viscous Damper (FVD). In this Final Project, three 20-story steel frame structures will be compared. The first structure is not equipped with FVD, the second structure is equipped with low-viscosity FVD, and the third structure is equipped with high-viscosity FVD. The Final Project begins with calculating the damping coefficient values for each model, provided by Taylor Devices, using low and high fluid viscosity values. Then, both structures equipped with FVD are analyzed with linear time history analysis using ETABS v21.0.0 software. These two structures must meet two criteria for structures with damper systems, namely maximum roof displacement and maximum inter-story drift. The FVD placement configuration of both structures is designed iteratively until these two criteria are met. Based on the results obtained from the Final Project, the structure with highviscosity FVD has smaller floor displacement and acceleration compared to the low-viscosity FVD during an earthquake, although the reduction is not significant. However, the high-viscosity FVD in the structure has a significantly higher hysteresis curve compared to the low-viscosity FVD during an earthquake. This means that the structure with high-viscosity FVD has a much better capability in damping earthquake vibrations than the structure with low-viscosity FVD. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Agustinus, Ernest
STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
description Indonesia is one of the countries located in the Pacific Ring of Fire. Consequently, Indonesia is susceptible to earthquake hazards. One of the devices capable of enhancing structural resilience against earthquakes is the Fluid Viscous Damper (FVD). In this Final Project, three 20-story steel frame structures will be compared. The first structure is not equipped with FVD, the second structure is equipped with low-viscosity FVD, and the third structure is equipped with high-viscosity FVD. The Final Project begins with calculating the damping coefficient values for each model, provided by Taylor Devices, using low and high fluid viscosity values. Then, both structures equipped with FVD are analyzed with linear time history analysis using ETABS v21.0.0 software. These two structures must meet two criteria for structures with damper systems, namely maximum roof displacement and maximum inter-story drift. The FVD placement configuration of both structures is designed iteratively until these two criteria are met. Based on the results obtained from the Final Project, the structure with highviscosity FVD has smaller floor displacement and acceleration compared to the low-viscosity FVD during an earthquake, although the reduction is not significant. However, the high-viscosity FVD in the structure has a significantly higher hysteresis curve compared to the low-viscosity FVD during an earthquake. This means that the structure with high-viscosity FVD has a much better capability in damping earthquake vibrations than the structure with low-viscosity FVD.
format Final Project
author Agustinus, Ernest
author_facet Agustinus, Ernest
author_sort Agustinus, Ernest
title STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
title_short STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
title_full STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
title_fullStr STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
title_full_unstemmed STUDY ON THE EFFECT OF FLUID VISCOSITY VALUES ON THE PERFORMANCE OF FLUID VISCOUS DAMPER (FVD) IN A 20-STORY STEEL FRAME STRUCTURE
title_sort study on the effect of fluid viscosity values on the performance of fluid viscous damper (fvd) in a 20-story steel frame structure
url https://digilib.itb.ac.id/gdl/view/82592
_version_ 1822282281937534976