AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY

The drive towards achieving Net Zero Emission goals in the future necessitates an energy transition. Power plants based on fossil fuels must be replaced with those based on new and renewable energy sources. In Indonesia, Renewable Energy Power Plants (REPPs) such as Solar Power Plants (SPPs) and...

Full description

Saved in:
Bibliographic Details
Main Author: Alfiandi, Radhitya
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/83382
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:83382
spelling id-itb.:833822024-08-09T07:52:57ZAUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY Alfiandi, Radhitya Indonesia Theses Automatic Dispatch Control System, Power Mismatch, Discrete Fourier Transform, Diesel Power Plant, BESS. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/83382 The drive towards achieving Net Zero Emission goals in the future necessitates an energy transition. Power plants based on fossil fuels must be replaced with those based on new and renewable energy sources. In Indonesia, Renewable Energy Power Plants (REPPs) such as Solar Power Plants (SPPs) and Wind Power Plants (WPPs) are highly favored. These plants are susceptible to weather intermittency, causing power fluctuations. These fluctuations affect the system frequency deviation, which must operate within normal conditions according to the Grid Code. Implementing an Automatic Dispatch Control System (ADCS) can control power generation to address frequency issues. With ADCS, the system can operate automatically and be controlled to adjust to real-time conditions, such as power fluctuations due to intermittent generation. In this study, the application of ADCS for dispatch control of diesel generators and Battery Energy Storage Systems (BESS) will be examined. ADCS control will be conducted for response times of one and three minutes. Fluctuation data from SPPs and WPPs will be recorded for 30 seconds. Without ADCS control, the system's frequency deviation operates outside the normal operating range due to power mismatches between scheduled and actual power due to fluctuations from SPPs and WPPs. With ADCS control, power fluctuations can be compensated for by diesel generators and BESS. Dispatch analysis will use Discrete Fourier Transform (DFT) analysis to divide the power mismatch signal into high and low-frequency components. The high-frequency power mismatch signal will be used for BESS dispatch, while the low-frequency signal will be used for diesel generator dispatch. The research results show that the ADCS response for a one-minute response time is better than for three minutes. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The drive towards achieving Net Zero Emission goals in the future necessitates an energy transition. Power plants based on fossil fuels must be replaced with those based on new and renewable energy sources. In Indonesia, Renewable Energy Power Plants (REPPs) such as Solar Power Plants (SPPs) and Wind Power Plants (WPPs) are highly favored. These plants are susceptible to weather intermittency, causing power fluctuations. These fluctuations affect the system frequency deviation, which must operate within normal conditions according to the Grid Code. Implementing an Automatic Dispatch Control System (ADCS) can control power generation to address frequency issues. With ADCS, the system can operate automatically and be controlled to adjust to real-time conditions, such as power fluctuations due to intermittent generation. In this study, the application of ADCS for dispatch control of diesel generators and Battery Energy Storage Systems (BESS) will be examined. ADCS control will be conducted for response times of one and three minutes. Fluctuation data from SPPs and WPPs will be recorded for 30 seconds. Without ADCS control, the system's frequency deviation operates outside the normal operating range due to power mismatches between scheduled and actual power due to fluctuations from SPPs and WPPs. With ADCS control, power fluctuations can be compensated for by diesel generators and BESS. Dispatch analysis will use Discrete Fourier Transform (DFT) analysis to divide the power mismatch signal into high and low-frequency components. The high-frequency power mismatch signal will be used for BESS dispatch, while the low-frequency signal will be used for diesel generator dispatch. The research results show that the ADCS response for a one-minute response time is better than for three minutes.
format Theses
author Alfiandi, Radhitya
spellingShingle Alfiandi, Radhitya
AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
author_facet Alfiandi, Radhitya
author_sort Alfiandi, Radhitya
title AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
title_short AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
title_full AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
title_fullStr AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
title_full_unstemmed AUTOMATIC DISPATCH CONTROL SYSTEM ANALYSIS USING DISCRETE FOURIER TRANSFORM TO ACHIEVE FREQUENCY STABILITY
title_sort automatic dispatch control system analysis using discrete fourier transform to achieve frequency stability
url https://digilib.itb.ac.id/gdl/view/83382
_version_ 1822998098240077824