INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD

This project studies the performance and capabilities of an Induced Draft Counter Flow Cooling Tower. This study starts with the geothermal plant. During the process of generating power, a geothermal plant will produce excess heat. This is where the cooling tower comes into play, it helps the system...

Full description

Saved in:
Bibliographic Details
Main Author: Al Aisy, Rihadatu
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/86474
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:86474
spelling id-itb.:864742024-09-19T15:24:19ZINDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD Al Aisy, Rihadatu Indonesia Final Project Cooling Tower, Induced Draft, Performance, Characteristic Curve Method. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/86474 This project studies the performance and capabilities of an Induced Draft Counter Flow Cooling Tower. This study starts with the geothermal plant. During the process of generating power, a geothermal plant will produce excess heat. This is where the cooling tower comes into play, it helps the system get rid of this heat. This study also explores basic principles and theories about cooling towers. The evaluation of this tower is performed using the characteristic method. In this method there are four main parameter values to be found. These are the test liquid to gas ratio, test tower characteristic, predicted liquid to gas ratio, and finally the capabilities. When obtaining these values other performance values will be found too. The methodology used adheres to the Cooling Tower Institute’s code titled “Acceptance Test Code for Water Cooling Towers” CTI ATC-105 Code. This code also provides a computer program to help obtain more reliable and precise psychrometric data. The subject of the project is to find and compare two cases of cooling tower performances. One cooling tower is at peak performance giving a capability of 100.96%. While the other has some disturbances resulting in a significantly reduced performance of 85.85% capability. One cooling tower removes heat better than the other. This shows that sometimes slight disturbances could drastically affect performance. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description This project studies the performance and capabilities of an Induced Draft Counter Flow Cooling Tower. This study starts with the geothermal plant. During the process of generating power, a geothermal plant will produce excess heat. This is where the cooling tower comes into play, it helps the system get rid of this heat. This study also explores basic principles and theories about cooling towers. The evaluation of this tower is performed using the characteristic method. In this method there are four main parameter values to be found. These are the test liquid to gas ratio, test tower characteristic, predicted liquid to gas ratio, and finally the capabilities. When obtaining these values other performance values will be found too. The methodology used adheres to the Cooling Tower Institute’s code titled “Acceptance Test Code for Water Cooling Towers” CTI ATC-105 Code. This code also provides a computer program to help obtain more reliable and precise psychrometric data. The subject of the project is to find and compare two cases of cooling tower performances. One cooling tower is at peak performance giving a capability of 100.96%. While the other has some disturbances resulting in a significantly reduced performance of 85.85% capability. One cooling tower removes heat better than the other. This shows that sometimes slight disturbances could drastically affect performance.
format Final Project
author Al Aisy, Rihadatu
spellingShingle Al Aisy, Rihadatu
INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
author_facet Al Aisy, Rihadatu
author_sort Al Aisy, Rihadatu
title INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
title_short INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
title_full INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
title_fullStr INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
title_full_unstemmed INDUCED DRAFT COOLING TOWER PERFORMANCE RESULTS USING CHARACTERISTIC CURVE METHOD
title_sort induced draft cooling tower performance results using characteristic curve method
url https://digilib.itb.ac.id/gdl/view/86474
_version_ 1822283430087360512