SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION

Liquid chromatography column particles are generally made of silica or polymer based materials. Various modifications are made to the material’s surface for the best separation performance. In this study, new silica-organik materials were synthesized from vinyltrimethoxysilane and divinylbenzen...

Full description

Saved in:
Bibliographic Details
Main Author: Mutiara Fitri, Annisa
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/86687
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:86687
spelling id-itb.:866872024-12-17T10:25:43ZSYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION Mutiara Fitri, Annisa Kimia Indonesia Theses Liquid Chromatography, MMA-co-DVB, Particles Column, Polymer@Silica, Silica-Organic, VTMS-co-DVB INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/86687 Liquid chromatography column particles are generally made of silica or polymer based materials. Various modifications are made to the material’s surface for the best separation performance. In this study, new silica-organik materials were synthesized from vinyltrimethoxysilane and divinylbenzene, whhich were compared with polymer@silica particles synthesized from silica-phenyl-modified methyl methacrylate and divinylbenzene. The polymer@silica particles obtained optimum results at a composition of 18,80 x 10-3 mol MMA + 25,25 x 10-3 mol DVB, after silica and phenyl modification obtained a homogeneous spheric particles with a diameter of 3,03 µm. FTIR spectra had peaks of 722, 1081 and 2855 cm-1 for Si-C, Si-O, dan C-H bonds, respectively. Optimum conditions for the 100 mm × 4,6 mm column were achieved at a mobile phase of methanol : water 60:40, flow rate 1,0 mL/min, and ? 274 nm, with Rs 3,86 and symmetrical factor 1,05. linearity was good in the range of 10-100 ppm, R2 0,994 for paracetamol and R2 0,996 for caffeine. Polymer@silica could separate paracetamol and caffeine, but could not separate paracetamol precursors (oxime and acetophenone). Silica-organic materials obtained optimum results at a composition of 23,51 x 10-3 mol VTMS + 28,05 x 10 3mol DVB, with homogeneous spheric particles of 2,3 µm diameter. FTIR spectra had peaks of 1000, 1081 and 2855 cm-1 for Si-C, Si-O, and C-H bonds, respectively. Optimum conditions for the 100 mm × 4,6 mm were achieved at a mobile phase of acetonitrile : water 15:85, a flow rate of 1,0 mL/min, and ? 274 nm with Rs 3,96 and symmetrical factor 1.10. Linearity was good in range of 10-100 ppm, R2 0,994 for paracetamol and R2 0,996 for caffeine. This silica-organic particles can separate the analysis of paracetamol, paracetamol precursor, and caffeine. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Mutiara Fitri, Annisa
SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
description Liquid chromatography column particles are generally made of silica or polymer based materials. Various modifications are made to the material’s surface for the best separation performance. In this study, new silica-organik materials were synthesized from vinyltrimethoxysilane and divinylbenzene, whhich were compared with polymer@silica particles synthesized from silica-phenyl-modified methyl methacrylate and divinylbenzene. The polymer@silica particles obtained optimum results at a composition of 18,80 x 10-3 mol MMA + 25,25 x 10-3 mol DVB, after silica and phenyl modification obtained a homogeneous spheric particles with a diameter of 3,03 µm. FTIR spectra had peaks of 722, 1081 and 2855 cm-1 for Si-C, Si-O, dan C-H bonds, respectively. Optimum conditions for the 100 mm × 4,6 mm column were achieved at a mobile phase of methanol : water 60:40, flow rate 1,0 mL/min, and ? 274 nm, with Rs 3,86 and symmetrical factor 1,05. linearity was good in the range of 10-100 ppm, R2 0,994 for paracetamol and R2 0,996 for caffeine. Polymer@silica could separate paracetamol and caffeine, but could not separate paracetamol precursors (oxime and acetophenone). Silica-organic materials obtained optimum results at a composition of 23,51 x 10-3 mol VTMS + 28,05 x 10 3mol DVB, with homogeneous spheric particles of 2,3 µm diameter. FTIR spectra had peaks of 1000, 1081 and 2855 cm-1 for Si-C, Si-O, and C-H bonds, respectively. Optimum conditions for the 100 mm × 4,6 mm were achieved at a mobile phase of acetonitrile : water 15:85, a flow rate of 1,0 mL/min, and ? 274 nm with Rs 3,96 and symmetrical factor 1.10. Linearity was good in range of 10-100 ppm, R2 0,994 for paracetamol and R2 0,996 for caffeine. This silica-organic particles can separate the analysis of paracetamol, paracetamol precursor, and caffeine.
format Theses
author Mutiara Fitri, Annisa
author_facet Mutiara Fitri, Annisa
author_sort Mutiara Fitri, Annisa
title SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
title_short SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
title_full SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
title_fullStr SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
title_full_unstemmed SYNTHESIS AND CHARACTERIZATION PARTICLE COLUMN LIQUID CHROMATOGRAPHY BASED POLYMER@SILICA AND SILICA-ORGANIC AND ITS APPLICATIONS FOR SEPARATION
title_sort synthesis and characterization particle column liquid chromatography based polymer@silica and silica-organic and its applications for separation
url https://digilib.itb.ac.id/gdl/view/86687
_version_ 1822011133644505088