#TITLE_ALTERNATIVE#

Sulfite (SO3(2-)) and thiosulfate (S2O3(2-)) are the best species for sulfur analysis because they are the main intermediates during sulfur analysis. In previously research, Differential Pulse Polarography (DPP) method have been developed for SO3(2-) and S2O3(2-) analysis. To find alternative electr...

Full description

Saved in:
Bibliographic Details
Main Author: MARINI (NIM 10503019), RINI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/9092
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:9092
spelling id-itb.:90922017-09-27T11:42:33Z#TITLE_ALTERNATIVE# MARINI (NIM 10503019), RINI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/9092 Sulfite (SO3(2-)) and thiosulfate (S2O3(2-)) are the best species for sulfur analysis because they are the main intermediates during sulfur analysis. In previously research, Differential Pulse Polarography (DPP) method have been developed for SO3(2-) and S2O3(2-) analysis. To find alternative electrode for SO3(2-) and S2O3(2-) analysis, mercury film electrodes on copper wire is used in this study. Squarewave voltammetry technique is used in this research. It has been found that S2O3(2-) can not be detected in all conditions studied, therefore optimization was only conducted for SO3(2-). The optimum wire diameter is 2,5 mm. Relative standard deviation for repeated measurement of 10 ppm SO3(2-) solution in acetate buffer solution pH 4,51 is 8,91% (n=20). The calibration plot for SO3(2-) solution was linear over concentration range of 10-160 ppm with detection limit of 3,71 ppm. The percent recovery for SO3(2-) is between 93,76-106,18%, showing good accuracy. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Sulfite (SO3(2-)) and thiosulfate (S2O3(2-)) are the best species for sulfur analysis because they are the main intermediates during sulfur analysis. In previously research, Differential Pulse Polarography (DPP) method have been developed for SO3(2-) and S2O3(2-) analysis. To find alternative electrode for SO3(2-) and S2O3(2-) analysis, mercury film electrodes on copper wire is used in this study. Squarewave voltammetry technique is used in this research. It has been found that S2O3(2-) can not be detected in all conditions studied, therefore optimization was only conducted for SO3(2-). The optimum wire diameter is 2,5 mm. Relative standard deviation for repeated measurement of 10 ppm SO3(2-) solution in acetate buffer solution pH 4,51 is 8,91% (n=20). The calibration plot for SO3(2-) solution was linear over concentration range of 10-160 ppm with detection limit of 3,71 ppm. The percent recovery for SO3(2-) is between 93,76-106,18%, showing good accuracy.
format Final Project
author MARINI (NIM 10503019), RINI
spellingShingle MARINI (NIM 10503019), RINI
#TITLE_ALTERNATIVE#
author_facet MARINI (NIM 10503019), RINI
author_sort MARINI (NIM 10503019), RINI
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/9092
_version_ 1820664593183145984