Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A

Frequency Response Function is a comparison function between response and excitation force which is presented in frequency domain, where the measurement of response and excitation force must be done simultaneously. ITB Dynamic Laboratory has developed softwares for FRF measurement using multiplexing...

Full description

Saved in:
Bibliographic Details
Main Author: (NIM 13103130), WILLIAM
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/9615
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:9615
spelling id-itb.:96152017-09-27T10:41:02ZComparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A (NIM 13103130), WILLIAM Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/9615 Frequency Response Function is a comparison function between response and excitation force which is presented in frequency domain, where the measurement of response and excitation force must be done simultaneously. ITB Dynamic Laboratory has developed softwares for FRF measurement using multiplexing data acquisition device and multi channel simultaneous data acquisition. Then, a research to see effects in using both of data acqusition devices in FRF measurement is needed. There were two softwares which is developed to control multiplexing data acquisition card PCI-6281 in this research. Each softwares can be used to do FRF measurement with impuls resopnse method and swept sine method. Those softwares were developed using LabVIEW 7.1 programming language, specific modul Sound and Vibration Toolkit 3.1, and device driver NI-DAQmx. In this research, FRF measurement was done with a T Plate and a simply supported beam structures using the developed softwares and MSA HP3566A, referenced data acquisition device. The developed softwares gave a wrong FRF measurement result since there was no anti-aliasing filter device in PCI-6281. The increased acquisition sampling rate returned small error in natural frequency reading and big error in the others FRF measurement unit reading. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Frequency Response Function is a comparison function between response and excitation force which is presented in frequency domain, where the measurement of response and excitation force must be done simultaneously. ITB Dynamic Laboratory has developed softwares for FRF measurement using multiplexing data acquisition device and multi channel simultaneous data acquisition. Then, a research to see effects in using both of data acqusition devices in FRF measurement is needed. There were two softwares which is developed to control multiplexing data acquisition card PCI-6281 in this research. Each softwares can be used to do FRF measurement with impuls resopnse method and swept sine method. Those softwares were developed using LabVIEW 7.1 programming language, specific modul Sound and Vibration Toolkit 3.1, and device driver NI-DAQmx. In this research, FRF measurement was done with a T Plate and a simply supported beam structures using the developed softwares and MSA HP3566A, referenced data acquisition device. The developed softwares gave a wrong FRF measurement result since there was no anti-aliasing filter device in PCI-6281. The increased acquisition sampling rate returned small error in natural frequency reading and big error in the others FRF measurement unit reading.
format Final Project
author (NIM 13103130), WILLIAM
spellingShingle (NIM 13103130), WILLIAM
Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
author_facet (NIM 13103130), WILLIAM
author_sort (NIM 13103130), WILLIAM
title Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
title_short Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
title_full Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
title_fullStr Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
title_full_unstemmed Comparison Evaluation of Frequency Response Function Measurement Result Using Multiplexing Data Acquisition Device PCI-6281 and Multi Channel Simultaneous Data Acquisition Device MSA HP3566A
title_sort comparison evaluation of frequency response function measurement result using multiplexing data acquisition device pci-6281 and multi channel simultaneous data acquisition device msa hp3566a
url https://digilib.itb.ac.id/gdl/view/9615
_version_ 1820664746544726016