#TITLE_ALTERNATIVE#

Magnetic Resonance Imaging (MRI) is a technical drawing based on the principle of the body section magnetic resonance hydrogen atom nucleus. Technical drawing of MRI is relatively complex because the resulting picture depends on many parameters. If the selecting parameters are right, the quality of...

Full description

Saved in:
Bibliographic Details
Main Author: ZIVANA (NIM 10205062), ALINE
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/9887
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:9887
spelling id-itb.:98872017-09-27T11:45:15Z#TITLE_ALTERNATIVE# ZIVANA (NIM 10205062), ALINE Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/9887 Magnetic Resonance Imaging (MRI) is a technical drawing based on the principle of the body section magnetic resonance hydrogen atom nucleus. Technical drawing of MRI is relatively complex because the resulting picture depends on many parameters. If the selecting parameters are right, the quality of the image body will be clear, so that the anatomy and pathology body network can be evaluated carefully.<p>This final project is done to study the influence of the value of the TE level image contrast and resolution T2-weight phantom by using spin echo pulse sequence imaging method on the MRI device with 0.5 Tesla in Hasan Sadikin Hospital,Bandung. Imaging uses variations of the value of TE 46.8ms to 360ms, and using a fixed TR of 3500ms with a value parameter imaging T2-weight is fixed too.<p>In T2-weight imaging, this phantom ROI data obtained were presented into the form of a curve T2 relaxation study for each level of explanation as a phantom image contrast. In addition, the level of image resolution is being checked on insert comb on the phantom variations TE value. Results obtained form curve contrast noise ratio (CNR) and graphic profile image phantom T2-weight variation in the value of each TE. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Magnetic Resonance Imaging (MRI) is a technical drawing based on the principle of the body section magnetic resonance hydrogen atom nucleus. Technical drawing of MRI is relatively complex because the resulting picture depends on many parameters. If the selecting parameters are right, the quality of the image body will be clear, so that the anatomy and pathology body network can be evaluated carefully.<p>This final project is done to study the influence of the value of the TE level image contrast and resolution T2-weight phantom by using spin echo pulse sequence imaging method on the MRI device with 0.5 Tesla in Hasan Sadikin Hospital,Bandung. Imaging uses variations of the value of TE 46.8ms to 360ms, and using a fixed TR of 3500ms with a value parameter imaging T2-weight is fixed too.<p>In T2-weight imaging, this phantom ROI data obtained were presented into the form of a curve T2 relaxation study for each level of explanation as a phantom image contrast. In addition, the level of image resolution is being checked on insert comb on the phantom variations TE value. Results obtained form curve contrast noise ratio (CNR) and graphic profile image phantom T2-weight variation in the value of each TE.
format Final Project
author ZIVANA (NIM 10205062), ALINE
spellingShingle ZIVANA (NIM 10205062), ALINE
#TITLE_ALTERNATIVE#
author_facet ZIVANA (NIM 10205062), ALINE
author_sort ZIVANA (NIM 10205062), ALINE
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/9887
_version_ 1820664824552488960