The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis
Purpose: To review the current clinical studies regarding the accuracy of implant computer-guided surgery in partially edentulous patients and investigate potential influencing factors. Study selection: Electronic searches on the PubMed and Cochrane Central Register of Controlled Trials databases...
Saved in:
id |
id-langga.107977 |
---|---|
record_format |
dspace |
spelling |
id-langga.1079772023-02-01T02:05:59Z https://repository.unair.ac.id/107977/ The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis Ramadhan Hardani Putra, - Nobuhiro Yoda, - Eha Renwi Astuti, - Keiichi Sasaki, - R Medicine RK Dentistry Purpose: To review the current clinical studies regarding the accuracy of implant computer-guided surgery in partially edentulous patients and investigate potential influencing factors. Study selection: Electronic searches on the PubMed and Cochrane Central Register of Controlled Trials databases, and subsequent manual searches were performed. Two reviewers selected the studies following our inclusion and exclusion criteria. Qualitative review and meta-analysis of the implant placement accuracy were performed to analyze potential influencing factors. Angular deviation, coronal deviation, apical deviation, and depth deviation were evaluated as the accuracy outcomes. Results: Eighteen studies were included in this systematic review, including six randomized controlled trials, nine prospective studies, and three retrospective clinical studies. A total of 1317 implants placed in 642 partially edentulous patients were reviewed. Eight studies were evaluated using meta-analysis. Fully guided surgery showed statistically higher accuracy in angular (P <0.001), coronal (P <0.001), and apical deviation (P <0.05) compared with pilot-drill guided surgery. A statistically significant difference (P <0.001) was also observed in coronal deviation between the bounded edentulous (BES) and distal extension spaces (DES). A significantly lower angular deviation (P <0.001) was found in implants placed using computer-aided design/computer-aided manufacturing (CAD/CAM) compared to the conventional surgical guides. Conclusions: The edentulous space type, surgical guide manufacturing procedure, and guided surgery protocol can influence the accuracy of computer-guided surgery in partially edentulous patients. Higher accuracy was found when the implants were placed in BES, with CAD/CAM manufactured surgical guides, using a fully guided surgery protocol. Journal of Prosthodontic Research 2021 Article PeerReviewed text en https://repository.unair.ac.id/107977/1/Artikel%2019.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing%20factors%20%20A%20systematic%20review%20and%20meta-analysis.pdf text en https://repository.unair.ac.id/107977/6/17.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing.pdf text id https://repository.unair.ac.id/107977/3/17.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing%20factors.pdf text en https://repository.unair.ac.id/107977/8/14.%20The%20accuracy%20of%20implant%20placement.pdf Ramadhan Hardani Putra, - and Nobuhiro Yoda, - and Eha Renwi Astuti, - and Keiichi Sasaki, - (2021) The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis. Journal of Prosthodontic Research, 65 (1). pp. 1-10. ISSN 1883-9207 |
institution |
Universitas Airlangga |
building |
Universitas Airlangga Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Universitas Airlangga Library |
collection |
UNAIR Repository |
language |
English English Indonesian English |
topic |
R Medicine RK Dentistry |
spellingShingle |
R Medicine RK Dentistry Ramadhan Hardani Putra, - Nobuhiro Yoda, - Eha Renwi Astuti, - Keiichi Sasaki, - The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
description |
Purpose: To review the current clinical studies regarding the accuracy of implant computer-guided surgery in partially edentulous patients and investigate potential influencing factors.
Study selection: Electronic searches on the PubMed and Cochrane Central Register of Controlled Trials databases, and subsequent manual searches were performed. Two reviewers selected the studies following our inclusion and exclusion criteria. Qualitative review and meta-analysis of the implant placement accuracy were performed to analyze potential influencing factors. Angular deviation, coronal deviation, apical deviation, and depth deviation were evaluated as the accuracy outcomes.
Results: Eighteen studies were included in this systematic review, including six randomized controlled trials, nine prospective studies, and three retrospective clinical studies. A total of 1317 implants placed in 642 partially edentulous patients were reviewed. Eight studies were evaluated using meta-analysis. Fully guided surgery showed statistically higher accuracy in angular (P <0.001), coronal (P <0.001), and apical deviation (P <0.05) compared with pilot-drill guided surgery. A statistically significant difference (P <0.001) was also observed in coronal deviation between the bounded edentulous (BES) and distal extension spaces (DES). A significantly lower angular deviation (P <0.001) was found in implants placed using computer-aided design/computer-aided manufacturing (CAD/CAM) compared to the conventional surgical guides.
Conclusions: The edentulous space type, surgical guide manufacturing procedure, and guided surgery protocol can influence the accuracy of computer-guided surgery in partially edentulous patients. Higher accuracy was found when the implants were placed in BES, with CAD/CAM manufactured surgical guides, using a fully guided surgery protocol. |
format |
Article PeerReviewed |
author |
Ramadhan Hardani Putra, - Nobuhiro Yoda, - Eha Renwi Astuti, - Keiichi Sasaki, - |
author_facet |
Ramadhan Hardani Putra, - Nobuhiro Yoda, - Eha Renwi Astuti, - Keiichi Sasaki, - |
author_sort |
Ramadhan Hardani Putra, - |
title |
The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
title_short |
The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
title_full |
The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
title_fullStr |
The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
title_full_unstemmed |
The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : A systematic review and meta-analysis |
title_sort |
accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors : a systematic review and meta-analysis |
publisher |
Journal of Prosthodontic Research |
publishDate |
2021 |
url |
https://repository.unair.ac.id/107977/1/Artikel%2019.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing%20factors%20%20A%20systematic%20review%20and%20meta-analysis.pdf https://repository.unair.ac.id/107977/6/17.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing.pdf https://repository.unair.ac.id/107977/3/17.%20The%20accuracy%20of%20implant%20placement%20with%20computer-guided%20surgery%20in%20partially%20edentulous%20patients%20and%20possible%20influencing%20factors.pdf https://repository.unair.ac.id/107977/8/14.%20The%20accuracy%20of%20implant%20placement.pdf https://repository.unair.ac.id/107977/ |
_version_ |
1757049641102213120 |