Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia
Introduction Children with spastic cerebral palsy (CP) often show an increase in femoral anteversion angle (FAA). Computed tomography (CT) scan is the main modality for evaluating FAA in these patients, however, due to significant radiation exposure, it carries a high carcinogenic risk. FEMORA® sof...
Saved in:
Main Authors: | , , , , , , , , , , , , , , |
---|---|
Format: | Article PeerReviewed |
Language: | English Indonesian English English |
Published: |
Elsevier
2023
|
Subjects: | |
Online Access: | https://repository.unair.ac.id/133851/1/Heliyon_Dr.%20TRI_Syarat%20Khusus.pdf https://repository.unair.ac.id/133851/2/Validasi%20Karil%20Dr.%20TRI.pdf https://repository.unair.ac.id/133851/3/Turnitin_Validity_HELIYON.pdf https://repository.unair.ac.id/133851/4/Dr.%20TRI_Bukti%20Korespondensi_Syarat%20Khusus_Heliyon.pdf https://repository.unair.ac.id/133851/ https://www.sciencedirect.com/science/article/pii/S2405844023094513?ref=pdf_download&fr=RR-2&rr=8bc1a6ee8f27cdd5 https://doi.org/10.1016/j.heliyon.2023.e22243 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Airlangga |
Language: | English Indonesian English English |
id |
id-langga.133851 |
---|---|
record_format |
dspace |
spelling |
id-langga.1338512024-09-01T02:21:54Z https://repository.unair.ac.id/133851/ Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia Tri Wahyu Martanto, '- Yusuf Rizal, '- Irwanto, '- Sulis Bayusentono, '- Rosy Setiawati, '- Sri Andreani Utomo, '- Prastiya Indra Gunawan, '- Nurul Kusuma Wardani, '- Prima Hari Nastiti, '- Rachmat Agung Widodo, '- Moon Seok Park, '- Arif Zulkarnain, '- Hizbillah Yazid, '- Hendra Cahaya Kumara, '- Muhammad Ihsan Kitta, '- RD701-811 Orthopedic surgery RJ370-550 Diseases of children and adolescents Introduction Children with spastic cerebral palsy (CP) often show an increase in femoral anteversion angle (FAA). Computed tomography (CT) scan is the main modality for evaluating FAA in these patients, however, due to significant radiation exposure, it carries a high carcinogenic risk. FEMORA® software is expected to be able to accurately assess FAA even with conventional X-ray images that only require low radiation exposure. However, its validity has not been tested in various populations or CT devices. This study aimed to validate the FEMORA® software by comparing it to CT scans done on an Indonesian population. Material and methods All spastic CP patients of the outpatient clinic at Dr. Soetomo Hospital between March and November 2022, were included. The FEMORA® Software evaluation was performed by three examiners. The calculation results were averaged and compared with those of the CT scan. Intraclass correlation coefficient (ICC), reliability, and correlation were be assessed. Results There were 36 patients included in this study. Most were female (n = 22; 61,1 %) and the average age was 7,28 years old. Interobserver preoperative analysis using ICC showed good outcomes (p = 0.918; 95 % CI, 0.858–0.955). FAA measurement results using FEMORA® and CT scans were 41,71 ± 12,90 and 32,68 ± 11,85, respectively. Correlation coefficient between the two values is 0.634 (p < 0.001). Conclusion FEMORA® software demonstrates a good and significant correlation with FAA measurement using CT scan. Elsevier 2023-11 Article PeerReviewed text en https://repository.unair.ac.id/133851/1/Heliyon_Dr.%20TRI_Syarat%20Khusus.pdf text id https://repository.unair.ac.id/133851/2/Validasi%20Karil%20Dr.%20TRI.pdf text en https://repository.unair.ac.id/133851/3/Turnitin_Validity_HELIYON.pdf text en https://repository.unair.ac.id/133851/4/Dr.%20TRI_Bukti%20Korespondensi_Syarat%20Khusus_Heliyon.pdf Tri Wahyu Martanto, '- and Yusuf Rizal, '- and Irwanto, '- and Sulis Bayusentono, '- and Rosy Setiawati, '- and Sri Andreani Utomo, '- and Prastiya Indra Gunawan, '- and Nurul Kusuma Wardani, '- and Prima Hari Nastiti, '- and Rachmat Agung Widodo, '- and Moon Seok Park, '- and Arif Zulkarnain, '- and Hizbillah Yazid, '- and Hendra Cahaya Kumara, '- and Muhammad Ihsan Kitta, '- (2023) Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia. Heliyon, 9 (11). e22243. ISSN P-ISSN:2405-8440, E-ISSN:2405-8440 https://www.sciencedirect.com/science/article/pii/S2405844023094513?ref=pdf_download&fr=RR-2&rr=8bc1a6ee8f27cdd5 https://doi.org/10.1016/j.heliyon.2023.e22243 |
institution |
Universitas Airlangga |
building |
Universitas Airlangga Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Universitas Airlangga Library |
collection |
UNAIR Repository |
language |
English Indonesian English English |
topic |
RD701-811 Orthopedic surgery RJ370-550 Diseases of children and adolescents |
spellingShingle |
RD701-811 Orthopedic surgery RJ370-550 Diseases of children and adolescents Tri Wahyu Martanto, '- Yusuf Rizal, '- Irwanto, '- Sulis Bayusentono, '- Rosy Setiawati, '- Sri Andreani Utomo, '- Prastiya Indra Gunawan, '- Nurul Kusuma Wardani, '- Prima Hari Nastiti, '- Rachmat Agung Widodo, '- Moon Seok Park, '- Arif Zulkarnain, '- Hizbillah Yazid, '- Hendra Cahaya Kumara, '- Muhammad Ihsan Kitta, '- Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
description |
Introduction
Children with spastic cerebral palsy (CP) often show an increase in femoral anteversion angle (FAA). Computed tomography (CT) scan is the main modality for evaluating FAA in these patients, however, due to significant radiation exposure, it carries a high carcinogenic risk. FEMORA® software is expected to be able to accurately assess FAA even with conventional X-ray images that only require low radiation exposure. However, its validity has not been tested in various populations or CT devices. This study aimed to validate the FEMORA® software by comparing it to CT scans done on an Indonesian population.
Material and methods
All spastic CP patients of the outpatient clinic at Dr. Soetomo Hospital between March and November 2022, were included. The FEMORA® Software evaluation was performed by three examiners. The calculation results were averaged and compared with those of the CT scan. Intraclass correlation coefficient (ICC), reliability, and correlation were be assessed.
Results
There were 36 patients included in this study. Most were female (n = 22; 61,1 %) and the average age was 7,28 years old. Interobserver preoperative analysis using ICC showed good outcomes (p = 0.918; 95 % CI, 0.858–0.955). FAA measurement results using FEMORA® and CT scans were 41,71 ± 12,90 and 32,68 ± 11,85, respectively. Correlation coefficient between the two values is 0.634 (p < 0.001).
Conclusion
FEMORA® software demonstrates a good and significant correlation with FAA measurement using CT scan. |
format |
Article PeerReviewed |
author |
Tri Wahyu Martanto, '- Yusuf Rizal, '- Irwanto, '- Sulis Bayusentono, '- Rosy Setiawati, '- Sri Andreani Utomo, '- Prastiya Indra Gunawan, '- Nurul Kusuma Wardani, '- Prima Hari Nastiti, '- Rachmat Agung Widodo, '- Moon Seok Park, '- Arif Zulkarnain, '- Hizbillah Yazid, '- Hendra Cahaya Kumara, '- Muhammad Ihsan Kitta, '- |
author_facet |
Tri Wahyu Martanto, '- Yusuf Rizal, '- Irwanto, '- Sulis Bayusentono, '- Rosy Setiawati, '- Sri Andreani Utomo, '- Prastiya Indra Gunawan, '- Nurul Kusuma Wardani, '- Prima Hari Nastiti, '- Rachmat Agung Widodo, '- Moon Seok Park, '- Arif Zulkarnain, '- Hizbillah Yazid, '- Hendra Cahaya Kumara, '- Muhammad Ihsan Kitta, '- |
author_sort |
Tri Wahyu Martanto, '- |
title |
Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
title_short |
Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
title_full |
Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
title_fullStr |
Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
title_full_unstemmed |
Validity of measurement of femoral anteversion angle using FEMORA® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in Indonesia |
title_sort |
validity of measurement of femoral anteversion angle using femora® software based on two-dimensional radiographic imaging examination femur in children with cerebral palsy in indonesia |
publisher |
Elsevier |
publishDate |
2023 |
url |
https://repository.unair.ac.id/133851/1/Heliyon_Dr.%20TRI_Syarat%20Khusus.pdf https://repository.unair.ac.id/133851/2/Validasi%20Karil%20Dr.%20TRI.pdf https://repository.unair.ac.id/133851/3/Turnitin_Validity_HELIYON.pdf https://repository.unair.ac.id/133851/4/Dr.%20TRI_Bukti%20Korespondensi_Syarat%20Khusus_Heliyon.pdf https://repository.unair.ac.id/133851/ https://www.sciencedirect.com/science/article/pii/S2405844023094513?ref=pdf_download&fr=RR-2&rr=8bc1a6ee8f27cdd5 https://doi.org/10.1016/j.heliyon.2023.e22243 |
_version_ |
1809140023909416960 |