VALIDASI METODE KCKT UNTUK PENETAPAN KADAR FENOKSIETANOL, METIL PARABEN, ETIL PARABEN, PROPIL PARABEN, DAN BUTIL PARABEN DALAM SEDIAAN SUNSCREEN LOTION

A high performance liquid chromatography (HPLC) method for the assay of phenoxyethanol, methyl paraben, ethyl paraben, propyl paraben and butyl paraben in sunscreen lotion was developed and validated. The use of a High Pure Silica RP-18 endcapped column (125 x 4) mm and acetonitrile: methanol: water...

Full description

Saved in:
Bibliographic Details
Main Author: HAFIDZ AMAMUL ASYHAR, 051211133019
Format: Theses and Dissertations NonPeerReviewed
Language:Indonesian
Indonesian
Published: 2016
Subjects:
Online Access:http://repository.unair.ac.id/71525/1/FF.KF.61-17%20Asy%20v%20Abstrak.pdf
http://repository.unair.ac.id/71525/2/FF.KF.61-17%20Asy%20v.pdf
http://repository.unair.ac.id/71525/
http://lib.unair.ac.id
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Airlangga
Language: Indonesian
Indonesian
Description
Summary:A high performance liquid chromatography (HPLC) method for the assay of phenoxyethanol, methyl paraben, ethyl paraben, propyl paraben and butyl paraben in sunscreen lotion was developed and validated. The use of a High Pure Silica RP-18 endcapped column (125 x 4) mm and acetonitrile: methanol: water were used as the mobile phase with gradient system and the composition at 0 min is (10 : 20 : 70); 15th min (0 : 80 : 20); 17th min (10 : 20 : 70) and 1 mL/min flow rate system enabled five compounds to be separated simultaneously in one analytical run. The diode array detector was set at 258.8 nm and column temperature was set at 30ᵒC. The method was validated to demonstrate it’s selectivity, linearity, accuracy, presicion, and robustness. The calibration curve showed good linearity for all five analytes. The correlation coefficients were in all cases are greater than 0,999. Linearity regression graphic showed linear response over the range of concentration used (between 40% and 160% for each analytes). The average %recovery value for phenoxyethanol (119.65 ppm – 222.12 ppm) is 97.95% - 104.1%, methyl paraben (28.36 ppm – 52.7 ppm) 97.88% - 102.73%, ethyl paraben (6.60 ppm – 12.27 ppm) 102.14% - 107,14%, propyl paraben (4.20 ppm – 7.83 ppm) 89.35% - 108.03%, and butyl paraben (9.33 ppm – 17.30 ppm) 90.16% - 104.90% and the precisions (RSD) were less than 2% for all analytes. This method was proved to be selective and robust over the column temperature changing. The proposed method was successfully applied for analysis of mixture preservatives in sunscreen lotion products.