VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN

Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by...

Full description

Saved in:
Bibliographic Details
Main Author: RATIH SHINTA SARI, 051411131093
Format: Theses and Dissertations NonPeerReviewed
Language:Indonesian
Indonesian
Published: 2018
Subjects:
Online Access:http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf
http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf
http://repository.unair.ac.id/76738/
http://lib.unair.ac.id
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Airlangga
Language: Indonesian
Indonesian
id id-langga.76738
record_format dspace
spelling id-langga.767382018-12-13T16:24:56Z http://repository.unair.ac.id/76738/ VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN RATIH SHINTA SARI, 051411131093 RS200-201 Pharmaceutical dosage forms Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by using spectrophotometry in visible light region using color reagent. The reagents used were Eosin Y in Silver nitrate, Eosin Y and bromthymol blue. The selected color reagent was Eosin Y due to its selectivity to BKC. The wavelength of 552 nm was shown to be λmax because there was no absorbance of eosin Y reagent. In selectivity validation, Y eosin reagent only reacted with BKC alone, shown by the absorbance of benzalkonium chloride yet the absence absorbance of eosin Y reagent on placebo (Absorbance value obtained was 0.08920) at λmax of 552 nm. In linearity validation, the linear regression equation obtained was y = 0.0039x +0.2042, with correlation coefficient (r) of 0.9996 and Vxo of 1.94%. In accuracy validation, 3 times replication was done on each level of addition placebo into each level. At 50%, 100% and 120% the mean % recovery obtained were 96.24%, 103.44% and 98.31%, respectively, thus the mean % recovery of three was 98.31%. In precision validation, each of six replications were performed a test, with the mean % recovery of 101.17 and the RSD of 0.48%. Interday variation study showed a mean % recovery of 97.90% and RSD of 0.72%. In this study the assayed level of Benzalkonium Chloride in the eye drop preparation of Ciprofloxacin was 0.0061%. 2018 Thesis NonPeerReviewed text id http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf text id http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf RATIH SHINTA SARI, 051411131093 (2018) VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN. Skripsi thesis, Universitas Airlangga. http://lib.unair.ac.id
institution Universitas Airlangga
building Universitas Airlangga Library
country Indonesia
collection UNAIR Repository
language Indonesian
Indonesian
topic RS200-201 Pharmaceutical dosage forms
spellingShingle RS200-201 Pharmaceutical dosage forms
RATIH SHINTA SARI, 051411131093
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
description Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by using spectrophotometry in visible light region using color reagent. The reagents used were Eosin Y in Silver nitrate, Eosin Y and bromthymol blue. The selected color reagent was Eosin Y due to its selectivity to BKC. The wavelength of 552 nm was shown to be λmax because there was no absorbance of eosin Y reagent. In selectivity validation, Y eosin reagent only reacted with BKC alone, shown by the absorbance of benzalkonium chloride yet the absence absorbance of eosin Y reagent on placebo (Absorbance value obtained was 0.08920) at λmax of 552 nm. In linearity validation, the linear regression equation obtained was y = 0.0039x +0.2042, with correlation coefficient (r) of 0.9996 and Vxo of 1.94%. In accuracy validation, 3 times replication was done on each level of addition placebo into each level. At 50%, 100% and 120% the mean % recovery obtained were 96.24%, 103.44% and 98.31%, respectively, thus the mean % recovery of three was 98.31%. In precision validation, each of six replications were performed a test, with the mean % recovery of 101.17 and the RSD of 0.48%. Interday variation study showed a mean % recovery of 97.90% and RSD of 0.72%. In this study the assayed level of Benzalkonium Chloride in the eye drop preparation of Ciprofloxacin was 0.0061%.
format Theses and Dissertations
NonPeerReviewed
author RATIH SHINTA SARI, 051411131093
author_facet RATIH SHINTA SARI, 051411131093
author_sort RATIH SHINTA SARI, 051411131093
title VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
title_short VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
title_full VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
title_fullStr VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
title_full_unstemmed VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
title_sort validasi metode spektrofotometri sinar tampak untuk penetapan kadar benzalkonium klorida dalam sediaan tetes mata siprofloksasin
publishDate 2018
url http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf
http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf
http://repository.unair.ac.id/76738/
http://lib.unair.ac.id
_version_ 1681150653510975488