VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN
Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by...
Saved in:
Main Author: | |
---|---|
Format: | Theses and Dissertations NonPeerReviewed |
Language: | Indonesian Indonesian |
Published: |
2018
|
Subjects: | |
Online Access: | http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf http://repository.unair.ac.id/76738/ http://lib.unair.ac.id |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Airlangga |
Language: | Indonesian Indonesian |
id |
id-langga.76738 |
---|---|
record_format |
dspace |
spelling |
id-langga.767382018-12-13T16:24:56Z http://repository.unair.ac.id/76738/ VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN RATIH SHINTA SARI, 051411131093 RS200-201 Pharmaceutical dosage forms Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by using spectrophotometry in visible light region using color reagent. The reagents used were Eosin Y in Silver nitrate, Eosin Y and bromthymol blue. The selected color reagent was Eosin Y due to its selectivity to BKC. The wavelength of 552 nm was shown to be λmax because there was no absorbance of eosin Y reagent. In selectivity validation, Y eosin reagent only reacted with BKC alone, shown by the absorbance of benzalkonium chloride yet the absence absorbance of eosin Y reagent on placebo (Absorbance value obtained was 0.08920) at λmax of 552 nm. In linearity validation, the linear regression equation obtained was y = 0.0039x +0.2042, with correlation coefficient (r) of 0.9996 and Vxo of 1.94%. In accuracy validation, 3 times replication was done on each level of addition placebo into each level. At 50%, 100% and 120% the mean % recovery obtained were 96.24%, 103.44% and 98.31%, respectively, thus the mean % recovery of three was 98.31%. In precision validation, each of six replications were performed a test, with the mean % recovery of 101.17 and the RSD of 0.48%. Interday variation study showed a mean % recovery of 97.90% and RSD of 0.72%. In this study the assayed level of Benzalkonium Chloride in the eye drop preparation of Ciprofloxacin was 0.0061%. 2018 Thesis NonPeerReviewed text id http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf text id http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf RATIH SHINTA SARI, 051411131093 (2018) VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN. Skripsi thesis, Universitas Airlangga. http://lib.unair.ac.id |
institution |
Universitas Airlangga |
building |
Universitas Airlangga Library |
country |
Indonesia |
collection |
UNAIR Repository |
language |
Indonesian Indonesian |
topic |
RS200-201 Pharmaceutical dosage forms |
spellingShingle |
RS200-201 Pharmaceutical dosage forms RATIH SHINTA SARI, 051411131093 VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
description |
Benzalkonium Chloride (BKC) is a preservative commonly used in eye drops, yet if ≥0.03% of its concentration enters the eye, one must seek immediate medical treatment. Therefore, a validated assay method is required to determine preservative concentration in eye drops. The analysis was performed by using spectrophotometry in visible light region using color reagent. The reagents used were Eosin Y in Silver nitrate, Eosin Y and bromthymol blue. The selected color reagent was Eosin Y due to its selectivity to BKC. The wavelength of 552 nm was shown to be λmax because there was no absorbance of eosin Y reagent. In selectivity validation, Y eosin reagent only reacted with BKC alone, shown by the absorbance of benzalkonium chloride yet the absence absorbance of eosin Y reagent on placebo (Absorbance value obtained was 0.08920) at λmax of 552 nm. In linearity validation, the linear regression equation obtained was y = 0.0039x +0.2042, with correlation coefficient (r) of 0.9996 and Vxo of 1.94%. In accuracy validation, 3 times replication was done on each level of addition placebo into each level. At 50%, 100% and 120% the mean % recovery obtained were 96.24%, 103.44% and 98.31%, respectively, thus the mean % recovery of three was 98.31%. In precision validation, each of six replications were performed a test, with the mean % recovery of 101.17 and the RSD of 0.48%. Interday variation study showed a mean % recovery of 97.90% and RSD of 0.72%. In this study the assayed level of Benzalkonium Chloride in the eye drop preparation of Ciprofloxacin was 0.0061%. |
format |
Theses and Dissertations NonPeerReviewed |
author |
RATIH SHINTA SARI, 051411131093 |
author_facet |
RATIH SHINTA SARI, 051411131093 |
author_sort |
RATIH SHINTA SARI, 051411131093 |
title |
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
title_short |
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
title_full |
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
title_fullStr |
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
title_full_unstemmed |
VALIDASI METODE SPEKTROFOTOMETRI SINAR TAMPAK UNTUK PENETAPAN KADAR BENZALKONIUM KLORIDA DALAM SEDIAAN TETES MATA SIPROFLOKSASIN |
title_sort |
validasi metode spektrofotometri sinar tampak untuk penetapan kadar benzalkonium klorida dalam sediaan tetes mata siprofloksasin |
publishDate |
2018 |
url |
http://repository.unair.ac.id/76738/1/FF.KF.%2040-%2018%20Sar%20v%20Abstrak.pdf http://repository.unair.ac.id/76738/2/FF.KF.%2040-%2018%20Sar%20v.pdf http://repository.unair.ac.id/76738/ http://lib.unair.ac.id |
_version_ |
1681150653510975488 |