VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level
Abstract: The level of physical fitness is a body health parameter. It can be measured by several methods. The 12-minutes Cooper running test and ergocycle Astrand test for VO2max calculation are the most common in Indonesia. The aim of this study was to compare the cardiorespiratory physical fitnes...
Saved in:
Main Authors: | , , |
---|---|
Format: | Book Section PeerReviewed |
Language: | English English English |
Published: |
Scitepress
2017
|
Subjects: | |
Online Access: | http://repository.unair.ac.id/96835/1/Bukti%20C.28%20-%20Copy%20%283%29.pdf http://repository.unair.ac.id/96835/2/Peer%20Review%2031.pdf http://repository.unair.ac.id/96835/3/VO2MAX%20of%20Ergocycle%20Astrand%20Test%20Differs%20from%2012-Minutes%20Cooper%20Running%20Test%20on%20Medical%20Students%E2%80%99%20Physical%20Fitness%20Level_compressed.pdf http://repository.unair.ac.id/96835/ https://www.scitepress.org/PublicationsDetail.aspx?ID=E3nevMGK1%2fA%3d&t=1 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Airlangga |
Language: | English English English |
id |
id-langga.96835 |
---|---|
record_format |
dspace |
spelling |
id-langga.968352020-08-12T03:45:07Z http://repository.unair.ac.id/96835/ VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level Bella Anggi Afisha Atika Lilik Herawati R Medicine (General) RA Public aspects of medicine Abstract: The level of physical fitness is a body health parameter. It can be measured by several methods. The 12-minutes Cooper running test and ergocycle Astrand test for VO2max calculation are the most common in Indonesia. The aim of this study was to compare the cardiorespiratory physical fitness level between the 12-minutes Cooper running test and the ergocycle Astrand test. The subject of this study consisted of 20 male students of the Faculty of Medicine, Universitas Airlangga, aged between 19 and 22 years old with normal to overweight body mass index (BMI). Based on the ergocycle Astrand test, 25% of students showed very good category, 20% of students good, 20% of students moderate, and 35% of students poor. The average of VO2max was 41.01% mlO2/kgweight/minute. The 12-minutes Cooper running test revealed that 5% of students showed good category, 15% of students moderate, 25% of students poor, and 55% of students very poor. The average of VO2max was 32.34 mlO2/kgweight/minute. The 12-minutes Cooper running and ergocycle Astrand test on VO2max had a significant difference (p=0.002). The selection of measurement type and the result of physical fitness level should be considered further because they may have significant difference, e.g. the ergocycle Astrand test is a non-weight-bearing test and the 12-minutes Cooper running test is a weight-bearing test. Scitepress 2017 Book Section PeerReviewed text en http://repository.unair.ac.id/96835/1/Bukti%20C.28%20-%20Copy%20%283%29.pdf text en http://repository.unair.ac.id/96835/2/Peer%20Review%2031.pdf text en http://repository.unair.ac.id/96835/3/VO2MAX%20of%20Ergocycle%20Astrand%20Test%20Differs%20from%2012-Minutes%20Cooper%20Running%20Test%20on%20Medical%20Students%E2%80%99%20Physical%20Fitness%20Level_compressed.pdf Bella Anggi Afisha and Atika and Lilik Herawati (2017) VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level. In: Proceedings of Surabaya International Physiology Seminar: SIPS. Scitepress, Surabaya, pp. 178-181. ISBN 978-989-758-340-7 https://www.scitepress.org/PublicationsDetail.aspx?ID=E3nevMGK1%2fA%3d&t=1 10.5220/0007335201780181 |
institution |
Universitas Airlangga |
building |
Universitas Airlangga Library |
country |
Indonesia |
collection |
UNAIR Repository |
language |
English English English |
topic |
R Medicine (General) RA Public aspects of medicine |
spellingShingle |
R Medicine (General) RA Public aspects of medicine Bella Anggi Afisha Atika Lilik Herawati VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
description |
Abstract: The level of physical fitness is a body health parameter. It can be measured by several methods. The 12-minutes Cooper running test and ergocycle Astrand test for VO2max calculation are the most common in Indonesia. The aim of this study was to compare the cardiorespiratory physical fitness level between the 12-minutes Cooper running test and the ergocycle Astrand test. The subject of this study consisted of 20 male students of the Faculty of Medicine, Universitas Airlangga, aged between 19 and 22 years old with normal to overweight body mass index (BMI). Based on the ergocycle Astrand test, 25% of students showed very good category, 20% of students good, 20% of students moderate, and 35% of students poor. The average of VO2max was 41.01% mlO2/kgweight/minute. The 12-minutes Cooper running test revealed that 5% of students showed good category, 15% of students moderate, 25% of students poor, and 55% of students very poor. The average of VO2max was 32.34 mlO2/kgweight/minute. The 12-minutes Cooper running and ergocycle Astrand test on VO2max had a significant difference (p=0.002). The selection of measurement type and the result of physical fitness level should be considered further because they may have significant difference, e.g. the ergocycle Astrand test is a non-weight-bearing test and the 12-minutes Cooper running test is a weight-bearing test. |
format |
Book Section PeerReviewed |
author |
Bella Anggi Afisha Atika Lilik Herawati |
author_facet |
Bella Anggi Afisha Atika Lilik Herawati |
author_sort |
Bella Anggi Afisha |
title |
VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
title_short |
VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
title_full |
VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
title_fullStr |
VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
title_full_unstemmed |
VO2MAX of Ergocycle Astrand Test Differs from 12-Minutes Cooper Running Test on Medical Students’ Physical Fitness Level |
title_sort |
vo2max of ergocycle astrand test differs from 12-minutes cooper running test on medical students’ physical fitness level |
publisher |
Scitepress |
publishDate |
2017 |
url |
http://repository.unair.ac.id/96835/1/Bukti%20C.28%20-%20Copy%20%283%29.pdf http://repository.unair.ac.id/96835/2/Peer%20Review%2031.pdf http://repository.unair.ac.id/96835/3/VO2MAX%20of%20Ergocycle%20Astrand%20Test%20Differs%20from%2012-Minutes%20Cooper%20Running%20Test%20on%20Medical%20Students%E2%80%99%20Physical%20Fitness%20Level_compressed.pdf http://repository.unair.ac.id/96835/ https://www.scitepress.org/PublicationsDetail.aspx?ID=E3nevMGK1%2fA%3d&t=1 |
_version_ |
1681153707450826752 |