PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL

Development of the stripping voltammetric method for selective uric acid analysis through the glassy carbon (GC) and hanging mercury drop (HMD) electrode coating with molecular imprinting polymer (MIP) has been carried out. The polymer used as coating was synthesized from methacrylic acid (MAA) as m...

全面介紹

Saved in:
書目詳細資料
Main Authors: , DRA MIRATUL KHASANAH,M.SI, , Prof. Drs. Mudasir, M.Eng., Ph.D.
格式: Theses and Dissertations NonPeerReviewed
出版: [Yogyakarta] : Universitas Gadjah Mada 2012
主題:
ETD
在線閱讀:https://repository.ugm.ac.id/118117/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=57333
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Universitas Gadjah Mada
id id-ugm-repo.118117
record_format dspace
spelling id-ugm-repo.1181172016-03-04T08:46:07Z https://repository.ugm.ac.id/118117/ PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL , DRA MIRATUL KHASANAH,M.SI , Prof. Drs. Mudasir, M.Eng., Ph.D. ETD Development of the stripping voltammetric method for selective uric acid analysis through the glassy carbon (GC) and hanging mercury drop (HMD) electrode coating with molecular imprinting polymer (MIP) has been carried out. The polymer used as coating was synthesized from methacrylic acid (MAA) as monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker and uric acid as template at various molar ratios. The MIP for uric acid was obtained after extraction of uric acid from the polymer network. The resulted MIP was characterized by Fourier transform infrared (FTIR), scanning electron microscopy (SEM) and N2 adsorptiondesorption. The surface of electrode was coated with the polymer to give MIP-coated electrode at various time and potential. MIP-coated electrode was used as working electrode in voltammetry to determine uric acid concentration. Results show that the polymer has been successfully synthesized and the uric acid has been partially extracted from the framework. SEM images show that the surface of MIP had pores of �0.1 µm in diameter. The N2 adsorption-desorption data suggest that there is a small increase in the pore size distribution from 37.71 to 38.02 � after extraction of the template. The optimal coating potential of MIP on the surface of GC electrode is at -0.4 V (vs Ag/AgCl) during 60 s. The optimal coating potential and time of MIP on the HMD electrode are at -1 V (vs Ag/AgCl) and 60 s, respectively. Uric acid was accumulated on the MIP-coated electrode during 60 s. The polymethacrylic acid is a non-electrical conducting polymer. Polymer which is synthesized using molar ratio of MAA, EGDMA, uric acid at 1:3:1 shows the optimum performance as an uric acid sensor/template. The MIP-coated GC and HMD electrodes have shown their performance as a sensitive voltammetric sensor for uric acid. The analytical performance of the method using MIP coated GC electrode are as follow: sensitivity 0.5 µA/nM/cm 2 , limit of detection 4.1x10 -9 M, and recovery of 99.6 %. The MIP-coated HMD gives the sensitivity of 69.4 µA/nM/cm 2 , detection limit 6.0x10 -10 M and recovery 95.7%. The developed two methods have detection limits 10 4 -10 5 times lower than spectrophotometric one. The MIP-coated GC and HMD are very selective sensor for uric acid. The presence of ascorbic acid not significantly interfered on the uric acid analysis using MIP-coated GC electrode. Using MIP-coated HMD electrode, ascorbic acid, creatine and creatinine is found not to interfere the uric acid analysis. Analysis of uric acid in the real samples of serum by this voltammetric method tends to give the slightly lower results as compared to those done by spectrophotometric method.. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , DRA MIRATUL KHASANAH,M.SI and , Prof. Drs. Mudasir, M.Eng., Ph.D. (2012) PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=57333
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, DRA MIRATUL KHASANAH,M.SI
, Prof. Drs. Mudasir, M.Eng., Ph.D.
PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
description Development of the stripping voltammetric method for selective uric acid analysis through the glassy carbon (GC) and hanging mercury drop (HMD) electrode coating with molecular imprinting polymer (MIP) has been carried out. The polymer used as coating was synthesized from methacrylic acid (MAA) as monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker and uric acid as template at various molar ratios. The MIP for uric acid was obtained after extraction of uric acid from the polymer network. The resulted MIP was characterized by Fourier transform infrared (FTIR), scanning electron microscopy (SEM) and N2 adsorptiondesorption. The surface of electrode was coated with the polymer to give MIP-coated electrode at various time and potential. MIP-coated electrode was used as working electrode in voltammetry to determine uric acid concentration. Results show that the polymer has been successfully synthesized and the uric acid has been partially extracted from the framework. SEM images show that the surface of MIP had pores of �0.1 µm in diameter. The N2 adsorption-desorption data suggest that there is a small increase in the pore size distribution from 37.71 to 38.02 � after extraction of the template. The optimal coating potential of MIP on the surface of GC electrode is at -0.4 V (vs Ag/AgCl) during 60 s. The optimal coating potential and time of MIP on the HMD electrode are at -1 V (vs Ag/AgCl) and 60 s, respectively. Uric acid was accumulated on the MIP-coated electrode during 60 s. The polymethacrylic acid is a non-electrical conducting polymer. Polymer which is synthesized using molar ratio of MAA, EGDMA, uric acid at 1:3:1 shows the optimum performance as an uric acid sensor/template. The MIP-coated GC and HMD electrodes have shown their performance as a sensitive voltammetric sensor for uric acid. The analytical performance of the method using MIP coated GC electrode are as follow: sensitivity 0.5 µA/nM/cm 2 , limit of detection 4.1x10 -9 M, and recovery of 99.6 %. The MIP-coated HMD gives the sensitivity of 69.4 µA/nM/cm 2 , detection limit 6.0x10 -10 M and recovery 95.7%. The developed two methods have detection limits 10 4 -10 5 times lower than spectrophotometric one. The MIP-coated GC and HMD are very selective sensor for uric acid. The presence of ascorbic acid not significantly interfered on the uric acid analysis using MIP-coated GC electrode. Using MIP-coated HMD electrode, ascorbic acid, creatine and creatinine is found not to interfere the uric acid analysis. Analysis of uric acid in the real samples of serum by this voltammetric method tends to give the slightly lower results as compared to those done by spectrophotometric method..
format Theses and Dissertations
NonPeerReviewed
author , DRA MIRATUL KHASANAH,M.SI
, Prof. Drs. Mudasir, M.Eng., Ph.D.
author_facet , DRA MIRATUL KHASANAH,M.SI
, Prof. Drs. Mudasir, M.Eng., Ph.D.
author_sort , DRA MIRATUL KHASANAH,M.SI
title PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
title_short PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
title_full PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
title_fullStr PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
title_full_unstemmed PENGEMBANGAN METODE VOLTAMMETRI LUCUTAN UNTUK ANALISIS ASAM URAT MELALUI PELAPISAN ELEKTRODA DENGAN POLIMER CETAKAN MOLEKUL
title_sort pengembangan metode voltammetri lucutan untuk analisis asam urat melalui pelapisan elektroda dengan polimer cetakan molekul
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2012
url https://repository.ugm.ac.id/118117/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=57333
_version_ 1681230900656865280