VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
Cream is one of usually applied cosmetics. The presence of heavy metals added to cosmetic such as Zn and Hg can cause risks if over the allowed concentration. This study is to validate the mehod analysis of atomic absorption spectrofotometry for Zn determination and mercury analyzer for mercury dete...
Saved in:
Main Authors: | , |
---|---|
Format: | Theses and Dissertations NonPeerReviewed |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2013
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/121054/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61098 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
Summary: | Cream is one of usually applied cosmetics. The presence of heavy
metals added to cosmetic such as Zn and Hg can cause risks if over the
allowed concentration. This study is to validate the mehod analysis of atomic
absorption spectrofotometry for Zn determination and mercury analyzer for
mercury determination.
Validation of method anaylisis is according to International
Conference on Harmonization term by assesing several parameter figures
namely linearity, sensitivity, precision and accuration. Cream samples are
destructed by wet digestion using nitric acid-perchlorat mixture (1 : 1 v/v),
then analyzed with atomic absorption spectrofotometry for Zn and mercury
analyzer for Hg.
The method analysis linearity obtained over 0,99 for correlation
coefficient (r) and 0,995 for determination coefficient (r2) . Limit of detection
obtained were 2,8614 μg/g for Zn and 0,4749 μg/kg. Limit of quantitation
obtained were 9,5281 μg/g for Zn and 1,5827 μg/kg for Hg. Relative
standard deviation used to determinate repeatability and interday precision
obtained were on the allowed values of Horwitz and AOAC PVM. Accuration
value obtained by assesing percent recovery were also on the allowed values
of AOAC PVM. This validated method then applied to determine Zn and Hg
concentration in some cream cosmetics. The level concentration of Zn and Hg
obtained was below the allowed maximum concentration. |
---|