VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA

Cream is one of usually applied cosmetics. The presence of heavy metals added to cosmetic such as Zn and Hg can cause risks if over the allowed concentration. This study is to validate the mehod analysis of atomic absorption spectrofotometry for Zn determination and mercury analyzer for mercury dete...

全面介紹

Saved in:
書目詳細資料
Main Authors: , ERNI WIJAYANTI, , Dr. Abdul Rohman, M.Si., Apt.
格式: Theses and Dissertations NonPeerReviewed
出版: [Yogyakarta] : Universitas Gadjah Mada 2013
主題:
ETD
在線閱讀:https://repository.ugm.ac.id/121054/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61098
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Universitas Gadjah Mada
id id-ugm-repo.121054
record_format dspace
spelling id-ugm-repo.1210542016-03-04T08:33:47Z https://repository.ugm.ac.id/121054/ VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA , ERNI WIJAYANTI , Dr. Abdul Rohman, M.Si., Apt. ETD Cream is one of usually applied cosmetics. The presence of heavy metals added to cosmetic such as Zn and Hg can cause risks if over the allowed concentration. This study is to validate the mehod analysis of atomic absorption spectrofotometry for Zn determination and mercury analyzer for mercury determination. Validation of method anaylisis is according to International Conference on Harmonization term by assesing several parameter figures namely linearity, sensitivity, precision and accuration. Cream samples are destructed by wet digestion using nitric acid-perchlorat mixture (1 : 1 v/v), then analyzed with atomic absorption spectrofotometry for Zn and mercury analyzer for Hg. The method analysis linearity obtained over 0,99 for correlation coefficient (r) and 0,995 for determination coefficient (r2) . Limit of detection obtained were 2,8614 μg/g for Zn and 0,4749 μg/kg. Limit of quantitation obtained were 9,5281 μg/g for Zn and 1,5827 μg/kg for Hg. Relative standard deviation used to determinate repeatability and interday precision obtained were on the allowed values of Horwitz and AOAC PVM. Accuration value obtained by assesing percent recovery were also on the allowed values of AOAC PVM. This validated method then applied to determine Zn and Hg concentration in some cream cosmetics. The level concentration of Zn and Hg obtained was below the allowed maximum concentration. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , ERNI WIJAYANTI and , Dr. Abdul Rohman, M.Si., Apt. (2013) VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61098
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, ERNI WIJAYANTI
, Dr. Abdul Rohman, M.Si., Apt.
VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
description Cream is one of usually applied cosmetics. The presence of heavy metals added to cosmetic such as Zn and Hg can cause risks if over the allowed concentration. This study is to validate the mehod analysis of atomic absorption spectrofotometry for Zn determination and mercury analyzer for mercury determination. Validation of method anaylisis is according to International Conference on Harmonization term by assesing several parameter figures namely linearity, sensitivity, precision and accuration. Cream samples are destructed by wet digestion using nitric acid-perchlorat mixture (1 : 1 v/v), then analyzed with atomic absorption spectrofotometry for Zn and mercury analyzer for Hg. The method analysis linearity obtained over 0,99 for correlation coefficient (r) and 0,995 for determination coefficient (r2) . Limit of detection obtained were 2,8614 μg/g for Zn and 0,4749 μg/kg. Limit of quantitation obtained were 9,5281 μg/g for Zn and 1,5827 μg/kg for Hg. Relative standard deviation used to determinate repeatability and interday precision obtained were on the allowed values of Horwitz and AOAC PVM. Accuration value obtained by assesing percent recovery were also on the allowed values of AOAC PVM. This validated method then applied to determine Zn and Hg concentration in some cream cosmetics. The level concentration of Zn and Hg obtained was below the allowed maximum concentration.
format Theses and Dissertations
NonPeerReviewed
author , ERNI WIJAYANTI
, Dr. Abdul Rohman, M.Si., Apt.
author_facet , ERNI WIJAYANTI
, Dr. Abdul Rohman, M.Si., Apt.
author_sort , ERNI WIJAYANTI
title VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
title_short VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
title_full VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
title_fullStr VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
title_full_unstemmed VALIDASI METODE ANALISIS LOGAM SENG (Zn) SECARA SPEKTROFOTOMETRI SERAPAN ATOM SERTA LOGAM RAKSA (Hg) DENGAN MERCURY ANALYZER PADA KRIM KOSMETIKA
title_sort validasi metode analisis logam seng (zn) secara spektrofotometri serapan atom serta logam raksa (hg) dengan mercury analyzer pada krim kosmetika
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2013
url https://repository.ugm.ac.id/121054/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61098
_version_ 1681231442767511552