PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32

Prototype of measuring system for temperature and heart rate of the human body based on microcontroller ATMega32 has been made in this final project. The prototype has been designed to facilitate for monitoring of temperature and heart rate of the human body by means of the serial communication. Tem...

Full description

Saved in:
Bibliographic Details
Main Authors: , GERY MAULANA, , Bakhtiar Alldino Ardi Sumbodo, S.Si.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/121204/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61271
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.121204
record_format dspace
spelling id-ugm-repo.1212042016-03-04T08:37:23Z https://repository.ugm.ac.id/121204/ PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32 , GERY MAULANA , Bakhtiar Alldino Ardi Sumbodo, S.Si. ETD Prototype of measuring system for temperature and heart rate of the human body based on microcontroller ATMega32 has been made in this final project. The prototype has been designed to facilitate for monitoring of temperature and heart rate of the human body by means of the serial communication. Temperature and heart rate data will be shown in the Visual Basic 6.0 as interface. Design of the system is using microcontroller ATMega32, LM35 Sensor Temperature, and Heart Rate Sensor Chest Belt Kit. In this system. The results data of the measurement is strored in an extention file ASCII. The results can be stored automatically in specified time. Overall the system can perform retrieval temperature and heart rate data in one minute (60 seconds). From the results of testing the system, we can know that the heart rate and temperature sensor work well. The values of the heart rate from sensor heart rate have deviation when compared to the output data from stetoskop measurement. The deviation values is 0,56 bpm. As well, the deviation of temperature reading values is 0,23°C. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , GERY MAULANA and , Bakhtiar Alldino Ardi Sumbodo, S.Si. (2013) PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61271
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, GERY MAULANA
, Bakhtiar Alldino Ardi Sumbodo, S.Si.
PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
description Prototype of measuring system for temperature and heart rate of the human body based on microcontroller ATMega32 has been made in this final project. The prototype has been designed to facilitate for monitoring of temperature and heart rate of the human body by means of the serial communication. Temperature and heart rate data will be shown in the Visual Basic 6.0 as interface. Design of the system is using microcontroller ATMega32, LM35 Sensor Temperature, and Heart Rate Sensor Chest Belt Kit. In this system. The results data of the measurement is strored in an extention file ASCII. The results can be stored automatically in specified time. Overall the system can perform retrieval temperature and heart rate data in one minute (60 seconds). From the results of testing the system, we can know that the heart rate and temperature sensor work well. The values of the heart rate from sensor heart rate have deviation when compared to the output data from stetoskop measurement. The deviation values is 0,56 bpm. As well, the deviation of temperature reading values is 0,23°C.
format Theses and Dissertations
NonPeerReviewed
author , GERY MAULANA
, Bakhtiar Alldino Ardi Sumbodo, S.Si.
author_facet , GERY MAULANA
, Bakhtiar Alldino Ardi Sumbodo, S.Si.
author_sort , GERY MAULANA
title PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
title_short PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
title_full PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
title_fullStr PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
title_full_unstemmed PROTOTYPE OF HUMAN BODY TEMPERATURE AND HEART RATE MEASURING SYSTEM BASED ON MICROCONTROLLER ATMEGA32
title_sort prototype of human body temperature and heart rate measuring system based on microcontroller atmega32
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2013
url https://repository.ugm.ac.id/121204/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=61271
_version_ 1681231470801190912