STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)

The effect of heat exchangers on hot and cold reservoirs as the thermoacoustic device performance has been done. The position of the hot heat exchanger (HHE) is close to the end of the stack in a heat reservoir and the water are flowed on the minute of 30 th . Meanwhile the position of the cold heat...

Full description

Saved in:
Bibliographic Details
Main Authors: , ELISABETH K N P, , Prof. Dr. Agung Bambang Setio Utomo, S.U.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2013
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/124216/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=64336
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.124216
record_format dspace
spelling id-ugm-repo.1242162016-03-04T08:33:19Z https://repository.ugm.ac.id/124216/ STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA) , ELISABETH K N P , Prof. Dr. Agung Bambang Setio Utomo, S.U. ETD The effect of heat exchangers on hot and cold reservoirs as the thermoacoustic device performance has been done. The position of the hot heat exchanger (HHE) is close to the end of the stack in a heat reservoir and the water are flowed on the minute of 30 th . Meanwhile the position of the cold heat exchanger (CHE) in the cold reservoir is varied as 15 cm, 20 cm, 25 cm, 30 cm to 35 cm from the loudspeaker and the water are flowed on the minute of 90 th . In this case, the total time for the data taking is 120 minutes. Thermoacoustic refrigerator device consists of a 10 inch loudspeaker, the resonator in the form of PVC pipe with 80 cm in length and 5,25 cm in diameter, and stack of squash with length of 6 cm. The loudspeaker get input signal with a frequency of 103 Hz and a power of 80 W and 90 W. According to the temperature changes that occur in the hot and cold reservoir during the thermoacoustic refrigerator device operation, the CHE optimum position are shown at a distance of 35 cm from the sound source with the largest �TC is 7 °C for 80 W input power and 7,2 °C for 90 W input power. These results are consistent with the calculation of COPC (Carnot coefficient of performance), where both variations have the smallest COPC. The better performance of the refrigerator, the smaller the COPC. [Yogyakarta] : Universitas Gadjah Mada 2013 Thesis NonPeerReviewed , ELISABETH K N P and , Prof. Dr. Agung Bambang Setio Utomo, S.U. (2013) STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=64336
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, ELISABETH K N P
, Prof. Dr. Agung Bambang Setio Utomo, S.U.
STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
description The effect of heat exchangers on hot and cold reservoirs as the thermoacoustic device performance has been done. The position of the hot heat exchanger (HHE) is close to the end of the stack in a heat reservoir and the water are flowed on the minute of 30 th . Meanwhile the position of the cold heat exchanger (CHE) in the cold reservoir is varied as 15 cm, 20 cm, 25 cm, 30 cm to 35 cm from the loudspeaker and the water are flowed on the minute of 90 th . In this case, the total time for the data taking is 120 minutes. Thermoacoustic refrigerator device consists of a 10 inch loudspeaker, the resonator in the form of PVC pipe with 80 cm in length and 5,25 cm in diameter, and stack of squash with length of 6 cm. The loudspeaker get input signal with a frequency of 103 Hz and a power of 80 W and 90 W. According to the temperature changes that occur in the hot and cold reservoir during the thermoacoustic refrigerator device operation, the CHE optimum position are shown at a distance of 35 cm from the sound source with the largest �TC is 7 °C for 80 W input power and 7,2 °C for 90 W input power. These results are consistent with the calculation of COPC (Carnot coefficient of performance), where both variations have the smallest COPC. The better performance of the refrigerator, the smaller the COPC.
format Theses and Dissertations
NonPeerReviewed
author , ELISABETH K N P
, Prof. Dr. Agung Bambang Setio Utomo, S.U.
author_facet , ELISABETH K N P
, Prof. Dr. Agung Bambang Setio Utomo, S.U.
author_sort , ELISABETH K N P
title STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
title_short STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
title_full STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
title_fullStr STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
title_full_unstemmed STUDI PENGARUH PENUKAR PANAS UNTUK TANDON DINGIN DAN PANAS TERHADAP KINERJA SISTEM PENDINGIN TERMOAKUSTIK MENGGUNAKAN STACK BERBAHAN GAMBAS (LUFFA ACUTANGULA)
title_sort studi pengaruh penukar panas untuk tandon dingin dan panas terhadap kinerja sistem pendingin termoakustik menggunakan stack berbahan gambas (luffa acutangula)
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2013
url https://repository.ugm.ac.id/124216/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=64336
_version_ 1681232037167497216