ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT

BACKGROUND:Birth weight is one of the most important health factors to consider during labor because it will affect the mortality and the morbidity of both the mother and the fetus. Predicting the birth weight accurately prior to delivery enables the obstetrician to prevent any unwanted complication...

Full description

Saved in:
Bibliographic Details
Main Authors: , ROSINTA PRATIWI, , Prof.dr.H. Risanto Siswosudarmo, SpOG(K)
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/128353/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.128353
record_format dspace
spelling id-ugm-repo.1283532016-03-04T08:10:34Z https://repository.ugm.ac.id/128353/ ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT , ROSINTA PRATIWI , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) ETD BACKGROUND:Birth weight is one of the most important health factors to consider during labor because it will affect the mortality and the morbidity of both the mother and the fetus. Predicting the birth weight accurately prior to delivery enables the obstetrician to prevent any unwanted complication that may occur by allowing them to choose appropriate route of delivery. There is no method for directly measuring the birth weight of the fetus in the uterus of the mother. However, clinicians may estimate the weight of the fetus by measuring the biophysical profile of the fetus and physical changes of the pregnant mother. The two methods usually used to estimate the birth weight are ultrasonography and measuring the fundal height of the mother. AIM: The purpose of this study is to compare the accuracy of Risanto�s formula and ultrasonography to predict the fetal birth weight in full term pregnancies to determine if Risanto�s formula is suitable as a replacement for ultrasonography in Indonesia. METHOD: This study employs a cross-sectonal design to compare the accuracy of EFW Risanto and Ultrasonography in gestational age between 37-42 weeks. EFW Ultrasonography is estimated by Hadlock rule. Actual birth weight is calculated by calibrated fetal weighing machine. The differences between actual birth weight and EFW Risanto and EFW Ultrasonography are calculated. Paired T-Test is used to evaluate the significance of EFW Risanto and EFW Ultrasonography. RESULT: � Mean shown the negative value which means that the � mean of Risanto formula (151.4grams) was smaller compared to the mean of � mean of Ultrasonography (179.1 grams), and their difference is 27.8 grams. However, the p-value is 0.082. So there is no statistically significant correlation between Risanto formula and Ultrasonography to predict fetal birth weight. CONCLUSION: There is no statistically significance between Risanto formula and Ultrasonography to predict fetal birth weight. Risanto formula is not superior than Ultrasonography or vise-versa. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , ROSINTA PRATIWI and , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) (2014) ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, ROSINTA PRATIWI
, Prof.dr.H. Risanto Siswosudarmo, SpOG(K)
ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
description BACKGROUND:Birth weight is one of the most important health factors to consider during labor because it will affect the mortality and the morbidity of both the mother and the fetus. Predicting the birth weight accurately prior to delivery enables the obstetrician to prevent any unwanted complication that may occur by allowing them to choose appropriate route of delivery. There is no method for directly measuring the birth weight of the fetus in the uterus of the mother. However, clinicians may estimate the weight of the fetus by measuring the biophysical profile of the fetus and physical changes of the pregnant mother. The two methods usually used to estimate the birth weight are ultrasonography and measuring the fundal height of the mother. AIM: The purpose of this study is to compare the accuracy of Risanto�s formula and ultrasonography to predict the fetal birth weight in full term pregnancies to determine if Risanto�s formula is suitable as a replacement for ultrasonography in Indonesia. METHOD: This study employs a cross-sectonal design to compare the accuracy of EFW Risanto and Ultrasonography in gestational age between 37-42 weeks. EFW Ultrasonography is estimated by Hadlock rule. Actual birth weight is calculated by calibrated fetal weighing machine. The differences between actual birth weight and EFW Risanto and EFW Ultrasonography are calculated. Paired T-Test is used to evaluate the significance of EFW Risanto and EFW Ultrasonography. RESULT: � Mean shown the negative value which means that the � mean of Risanto formula (151.4grams) was smaller compared to the mean of � mean of Ultrasonography (179.1 grams), and their difference is 27.8 grams. However, the p-value is 0.082. So there is no statistically significant correlation between Risanto formula and Ultrasonography to predict fetal birth weight. CONCLUSION: There is no statistically significance between Risanto formula and Ultrasonography to predict fetal birth weight. Risanto formula is not superior than Ultrasonography or vise-versa.
format Theses and Dissertations
NonPeerReviewed
author , ROSINTA PRATIWI
, Prof.dr.H. Risanto Siswosudarmo, SpOG(K)
author_facet , ROSINTA PRATIWI
, Prof.dr.H. Risanto Siswosudarmo, SpOG(K)
author_sort , ROSINTA PRATIWI
title ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
title_short ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
title_full ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
title_fullStr ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
title_full_unstemmed ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
title_sort accuracy of risanto formula compared to ultrasound examination in predicting fetal birth weight
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2014
url https://repository.ugm.ac.id/128353/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693
_version_ 1681232779344347136