ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT
BACKGROUND:Birth weight is one of the most important health factors to consider during labor because it will affect the mortality and the morbidity of both the mother and the fetus. Predicting the birth weight accurately prior to delivery enables the obstetrician to prevent any unwanted complication...
Saved in:
Main Authors: | , |
---|---|
Format: | Theses and Dissertations NonPeerReviewed |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2014
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/128353/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
id |
id-ugm-repo.128353 |
---|---|
record_format |
dspace |
spelling |
id-ugm-repo.1283532016-03-04T08:10:34Z https://repository.ugm.ac.id/128353/ ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT , ROSINTA PRATIWI , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) ETD BACKGROUND:Birth weight is one of the most important health factors to consider during labor because it will affect the mortality and the morbidity of both the mother and the fetus. Predicting the birth weight accurately prior to delivery enables the obstetrician to prevent any unwanted complication that may occur by allowing them to choose appropriate route of delivery. There is no method for directly measuring the birth weight of the fetus in the uterus of the mother. However, clinicians may estimate the weight of the fetus by measuring the biophysical profile of the fetus and physical changes of the pregnant mother. The two methods usually used to estimate the birth weight are ultrasonography and measuring the fundal height of the mother. AIM: The purpose of this study is to compare the accuracy of Risanto�s formula and ultrasonography to predict the fetal birth weight in full term pregnancies to determine if Risanto�s formula is suitable as a replacement for ultrasonography in Indonesia. METHOD: This study employs a cross-sectonal design to compare the accuracy of EFW Risanto and Ultrasonography in gestational age between 37-42 weeks. EFW Ultrasonography is estimated by Hadlock rule. Actual birth weight is calculated by calibrated fetal weighing machine. The differences between actual birth weight and EFW Risanto and EFW Ultrasonography are calculated. Paired T-Test is used to evaluate the significance of EFW Risanto and EFW Ultrasonography. RESULT: � Mean shown the negative value which means that the � mean of Risanto formula (151.4grams) was smaller compared to the mean of � mean of Ultrasonography (179.1 grams), and their difference is 27.8 grams. However, the p-value is 0.082. So there is no statistically significant correlation between Risanto formula and Ultrasonography to predict fetal birth weight. CONCLUSION: There is no statistically significance between Risanto formula and Ultrasonography to predict fetal birth weight. Risanto formula is not superior than Ultrasonography or vise-versa. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , ROSINTA PRATIWI and , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) (2014) ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693 |
institution |
Universitas Gadjah Mada |
building |
UGM Library |
country |
Indonesia |
collection |
Repository Civitas UGM |
topic |
ETD |
spellingShingle |
ETD , ROSINTA PRATIWI , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) ACCURACY OF RISANTO FORMULA COMPARED TO ULTRASOUND EXAMINATION IN PREDICTING FETAL BIRTH WEIGHT |
description |
BACKGROUND:Birth weight is one of the most important
health factors to consider during labor because it will
affect the mortality and the morbidity of both the
mother and the fetus. Predicting the birth weight
accurately prior to delivery enables the obstetrician
to prevent any unwanted complication that may occur by
allowing them to choose appropriate route of delivery.
There is no method for directly measuring the birth
weight of the fetus in the uterus of the mother.
However, clinicians may estimate the weight of the
fetus by measuring the biophysical profile of the fetus
and physical changes of the pregnant mother. The two
methods usually used to estimate the birth weight are
ultrasonography and measuring the fundal height of the
mother.
AIM: The purpose of this study is to compare the
accuracy of Risanto�s formula and ultrasonography to
predict the fetal birth weight in full term pregnancies
to determine if Risanto�s formula is suitable as a
replacement for ultrasonography in Indonesia.
METHOD: This study employs a cross-sectonal design to
compare the accuracy of EFW Risanto and Ultrasonography
in gestational age between 37-42 weeks. EFW
Ultrasonography is estimated by Hadlock rule. Actual
birth weight is calculated by calibrated fetal weighing
machine. The differences between actual birth weight
and EFW Risanto and EFW Ultrasonography are calculated.
Paired T-Test is used to evaluate the significance of
EFW Risanto and EFW Ultrasonography.
RESULT: � Mean shown the negative value which means
that the � mean of Risanto formula (151.4grams) was
smaller compared to the mean of � mean of
Ultrasonography (179.1 grams), and their difference is
27.8 grams. However, the p-value is 0.082. So there is
no statistically significant correlation between
Risanto formula and Ultrasonography to predict fetal
birth weight.
CONCLUSION: There is no statistically significance
between Risanto formula and Ultrasonography to predict
fetal birth weight. Risanto formula is not superior
than Ultrasonography or vise-versa. |
format |
Theses and Dissertations NonPeerReviewed |
author |
, ROSINTA PRATIWI , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) |
author_facet |
, ROSINTA PRATIWI , Prof.dr.H. Risanto Siswosudarmo, SpOG(K) |
author_sort |
, ROSINTA PRATIWI |
title |
ACCURACY OF RISANTO FORMULA
COMPARED TO ULTRASOUND EXAMINATION IN
PREDICTING FETAL BIRTH WEIGHT |
title_short |
ACCURACY OF RISANTO FORMULA
COMPARED TO ULTRASOUND EXAMINATION IN
PREDICTING FETAL BIRTH WEIGHT |
title_full |
ACCURACY OF RISANTO FORMULA
COMPARED TO ULTRASOUND EXAMINATION IN
PREDICTING FETAL BIRTH WEIGHT |
title_fullStr |
ACCURACY OF RISANTO FORMULA
COMPARED TO ULTRASOUND EXAMINATION IN
PREDICTING FETAL BIRTH WEIGHT |
title_full_unstemmed |
ACCURACY OF RISANTO FORMULA
COMPARED TO ULTRASOUND EXAMINATION IN
PREDICTING FETAL BIRTH WEIGHT |
title_sort |
accuracy of risanto formula
compared to ultrasound examination in
predicting fetal birth weight |
publisher |
[Yogyakarta] : Universitas Gadjah Mada |
publishDate |
2014 |
url |
https://repository.ugm.ac.id/128353/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=68693 |
_version_ |
1681232779344347136 |