VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)

Analysis technology of pesticide residues more develop in a row with increases usage pesticide in a field. There are several of residues analysis method, one of them is HPLC. This research aims to perform validate posseses of analysis deltamethrin using a Shimadzu 6.1 high-performance liquid chromat...

Full description

Saved in:
Bibliographic Details
Main Authors: , PRADITA RENDYAWAN, , drh. R. Gagak Donny Satria, M.P., M.Pd.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/131360/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=71816
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.131360
record_format dspace
spelling id-ugm-repo.1313602016-03-04T08:06:27Z https://repository.ugm.ac.id/131360/ VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT) , PRADITA RENDYAWAN , drh. R. Gagak Donny Satria, M.P., M.Pd. ETD Analysis technology of pesticide residues more develop in a row with increases usage pesticide in a field. There are several of residues analysis method, one of them is HPLC. This research aims to perform validate posseses of analysis deltamethrin using a Shimadzu 6.1 high-performance liquid chromatography (HPLC) with control system SCL-10 A VP, DGU-14 A degasser. Mobile phase of Merck acetonitrile 80% in steryl aquadest, flow rate of 1.25 ml/minute, UV-Vis SPD 10 AV VP detector with wavelength of 236 nm and used Shimadzu Shim-pack 150 L x 4.6 mm VP-ODS Column C18 on temperature 30 oC. The validation examination is based on specificity, precision, accuracy, limit of qualitative, quantitative limits, and linearity. Results of the research shows the average of area concentration 1 μg/ml, 2 μg/ml, and 5 μg/ml in consecutive are 34620.33, 79048.67, dan 181208.7 with retention time in 8.6-8.98 minute. Repeatability is clone 3 times and the RSD mean value obtained is � 2%. The detection limit at 0.1 μg/ml and limit of quantification at concententration 1 μg/ml. The equation of linear line y = 36046x+2182, with the value of R= 0.99. It can be concluded that the method used in the research posseses good validity. [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , PRADITA RENDYAWAN and , drh. R. Gagak Donny Satria, M.P., M.Pd. (2014) VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=71816
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, PRADITA RENDYAWAN
, drh. R. Gagak Donny Satria, M.P., M.Pd.
VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
description Analysis technology of pesticide residues more develop in a row with increases usage pesticide in a field. There are several of residues analysis method, one of them is HPLC. This research aims to perform validate posseses of analysis deltamethrin using a Shimadzu 6.1 high-performance liquid chromatography (HPLC) with control system SCL-10 A VP, DGU-14 A degasser. Mobile phase of Merck acetonitrile 80% in steryl aquadest, flow rate of 1.25 ml/minute, UV-Vis SPD 10 AV VP detector with wavelength of 236 nm and used Shimadzu Shim-pack 150 L x 4.6 mm VP-ODS Column C18 on temperature 30 oC. The validation examination is based on specificity, precision, accuracy, limit of qualitative, quantitative limits, and linearity. Results of the research shows the average of area concentration 1 μg/ml, 2 μg/ml, and 5 μg/ml in consecutive are 34620.33, 79048.67, dan 181208.7 with retention time in 8.6-8.98 minute. Repeatability is clone 3 times and the RSD mean value obtained is � 2%. The detection limit at 0.1 μg/ml and limit of quantification at concententration 1 μg/ml. The equation of linear line y = 36046x+2182, with the value of R= 0.99. It can be concluded that the method used in the research posseses good validity.
format Theses and Dissertations
NonPeerReviewed
author , PRADITA RENDYAWAN
, drh. R. Gagak Donny Satria, M.P., M.Pd.
author_facet , PRADITA RENDYAWAN
, drh. R. Gagak Donny Satria, M.P., M.Pd.
author_sort , PRADITA RENDYAWAN
title VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_short VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_full VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_fullStr VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_full_unstemmed VALIDASI PROSEDUR ANALISIS DELTAMETHRIN PADA DAGING AYAM BROILER MENGGUNAKAN ALAT KROMATOGRAFI CAIR KINERJA TINGGI (KCKT)
title_sort validasi prosedur analisis deltamethrin pada daging ayam broiler menggunakan alat kromatografi cair kinerja tinggi (kckt)
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2014
url https://repository.ugm.ac.id/131360/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=71816
_version_ 1681233311083528192