KAPASITAS LENTUR BALOK KOMPOSIT BETON-BAJA RINGAN
Generally, reinforced concrete is composite materials concrete and bar reinforce. This study can be developed composite of reinforced concrete to be composite concrete-mild steel. Characteristic of mild steel are light in weight and thin, mild steel have height strength. On Indonesia Standard (SNI 4...
Saved in:
Main Authors: | , |
---|---|
Format: | Theses and Dissertations NonPeerReviewed |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2014
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/132967/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=73512 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
Summary: | Generally, reinforced concrete is composite materials concrete and bar reinforce. This
study can be developed composite of reinforced concrete to be composite concrete-mild steel.
Characteristic of mild steel are light in weight and thin, mild steel have height strength. On
Indonesia Standard (SNI 4096:2007) said, mild steel for structure (G550) have minimum
strength 550 MPa. Quality strength of mild steel same with strength of bar reinforce BJ 41
quality. So if according to theory, mild steel can be change bar reinforce on concrete
technology.
Study of composite concrete-mild steel did to beam, with observed beam flexure
capacity. Beam sample designed with mild steel G550 quality, 1 mm thickness, designed by
Blue Scope Steel and readymix concrete designed by Holcim K-300 concrete quality. Beam
used mild steel as formwork and beam cover
Testing beam used point load at middle beam, and spacing point�s beam are 2300mm.
Analysis result to maximum load of beam is 177.05 kN. Result for tensile strength testing of
mild steel is mean 668,64 MPa, and result for concrete compression testing is mean 286 MPa
on 14th days. Result of flexural testing, beam can be held more 152 kN load. |
---|