PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN

The post-rain puddles that happened in the Main Yard of Prambanan Temple is very bothering visitor mobility. Related technical data collecting of soil characteristic in the yard of Prambanan Temple require to be done to get correct solution of this problems. Coefficient permeability represent one of...

Full description

Saved in:
Bibliographic Details
Main Authors: , WILLIAM HENDRA PARULIAN SIAGIAN, , Dr. Ir. Ahmad Rifa�i, M.T.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2014
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/134567/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=77494
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.134567
record_format dspace
spelling id-ugm-repo.1345672016-03-04T08:17:20Z https://repository.ugm.ac.id/134567/ PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN , WILLIAM HENDRA PARULIAN SIAGIAN , Dr. Ir. Ahmad Rifa�i, M.T. ETD The post-rain puddles that happened in the Main Yard of Prambanan Temple is very bothering visitor mobility. Related technical data collecting of soil characteristic in the yard of Prambanan Temple require to be done to get correct solution of this problems. Coefficient permeability represent one of the very important parameter to be determined. Quick and simple field direct of permeability testing was needed to collect data which is represented the condition in field. Preparation in making device model and testing procedure conducted by developing field permeability testing devices which have been done by Forchheimer (1930), Sunjoto (1988), Putra and Setyanto (2012), and also Takeshita and Komatsu (2012). Testing procedure development was also based on constant-head and falling-head permeability testing methode and principle. Laboratory test like constant-head, done as the comparison with insitu test result. Hydraulic conductivity soil mapping use the Arcview GIS 3.3 software. Two models of permeability testing that was used, Model I (immediate flow model) and Model II (constant discharge model). Both of developed hydraulic conductivity device model and testing procedure at this research is effective enough, efficient, economic, simple, and easy to determine field permeability coefficient value of sandy soils. Soil permeability coefficient in unsaturated condition (kunsat) can be obtained by using Model II without making Soil Water Characteristic Curve that needs suction matrix measurement which costly enough. Presentation of soil permeability value in mapping that use Arcview GIS 3.3 software can explain the Prambanan Temple Yard soil permeability character and condition and also spatial relationship between one point with other point or between geospasial data. Keywords: puddle, device model, testing procedure, permeability coefficient [Yogyakarta] : Universitas Gadjah Mada 2014 Thesis NonPeerReviewed , WILLIAM HENDRA PARULIAN SIAGIAN and , Dr. Ir. Ahmad Rifa�i, M.T. (2014) PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=77494
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, WILLIAM HENDRA PARULIAN SIAGIAN
, Dr. Ir. Ahmad Rifa�i, M.T.
PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
description The post-rain puddles that happened in the Main Yard of Prambanan Temple is very bothering visitor mobility. Related technical data collecting of soil characteristic in the yard of Prambanan Temple require to be done to get correct solution of this problems. Coefficient permeability represent one of the very important parameter to be determined. Quick and simple field direct of permeability testing was needed to collect data which is represented the condition in field. Preparation in making device model and testing procedure conducted by developing field permeability testing devices which have been done by Forchheimer (1930), Sunjoto (1988), Putra and Setyanto (2012), and also Takeshita and Komatsu (2012). Testing procedure development was also based on constant-head and falling-head permeability testing methode and principle. Laboratory test like constant-head, done as the comparison with insitu test result. Hydraulic conductivity soil mapping use the Arcview GIS 3.3 software. Two models of permeability testing that was used, Model I (immediate flow model) and Model II (constant discharge model). Both of developed hydraulic conductivity device model and testing procedure at this research is effective enough, efficient, economic, simple, and easy to determine field permeability coefficient value of sandy soils. Soil permeability coefficient in unsaturated condition (kunsat) can be obtained by using Model II without making Soil Water Characteristic Curve that needs suction matrix measurement which costly enough. Presentation of soil permeability value in mapping that use Arcview GIS 3.3 software can explain the Prambanan Temple Yard soil permeability character and condition and also spatial relationship between one point with other point or between geospasial data. Keywords: puddle, device model, testing procedure, permeability coefficient
format Theses and Dissertations
NonPeerReviewed
author , WILLIAM HENDRA PARULIAN SIAGIAN
, Dr. Ir. Ahmad Rifa�i, M.T.
author_facet , WILLIAM HENDRA PARULIAN SIAGIAN
, Dr. Ir. Ahmad Rifa�i, M.T.
author_sort , WILLIAM HENDRA PARULIAN SIAGIAN
title PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
title_short PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
title_full PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
title_fullStr PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
title_full_unstemmed PENGEMBANGAN ALAT DAN PROSEDUR UJI HYDRAULIC CONDUCTIVITY (KOEFISIEN PERMEABILITAS) TANAH HALAMAN I CANDI PRAMBANAN BESERTA PEMETAAN HASIL UJI DI LAPANGAN
title_sort pengembangan alat dan prosedur uji hydraulic conductivity (koefisien permeabilitas) tanah halaman i candi prambanan beserta pemetaan hasil uji di lapangan
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2014
url https://repository.ugm.ac.id/134567/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=77494
_version_ 1681233886907990016