RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...

The Extra High Voltage Transmission Line (EHVTL) which was construction in the populated area creates significant implication in psychological impact to the people. It must be due to the rumor that the non-ionizing electromagnetic radiation causes some problem in the surrounding people's health...

Full description

Saved in:
Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article NonPeerReviewed
Published: [Yogyakarta] : Laboratorium aekologi Fak. Biologi UGM 2006
Subjects:
Online Access:https://repository.ugm.ac.id/21678/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=4549
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.21678
record_format dspace
spelling id-ugm-repo.216782014-06-18T00:26:11Z https://repository.ugm.ac.id/21678/ RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ... Perpustakaan UGM, i-lib Jurnal i-lib UGM The Extra High Voltage Transmission Line (EHVTL) which was construction in the populated area creates significant implication in psychological impact to the people. It must be due to the rumor that the non-ionizing electromagnetic radiation causes some problem in the surrounding people's health. In order to confirm the non-ionizing radiation impact on the people, the research has been conducted around of EHVTL, which is located in Bowan Village, District Delanggu, Klaten, Central Java, Indonesia. A detector for non-ionizing radiation were developed and used accordingly. The simulation results and the measurement results show that the maximum intensity of electrics field levels were 0.014kV/m. These levels are significantly lower than the maximum level of the International Standard for Non-Ionizing Radiation Level, i.e., 10 kV/m. Average the maximum intensity of magnetic field levels were 0.650mT, which are higher than the maximum level of the International Standard for Non-Ionizing Radiation Level, i.e., O.5mT. This detector for non-ionizing radiation can as well be used by the designers and engineers who work in the electric energy transmission field. Keywords: non-ionizing radiation, electromagnetic, electrics field, magnetisms fiel [Yogyakarta] : Laboratorium aekologi Fak. Biologi UGM 2006 Article NonPeerReviewed Perpustakaan UGM, i-lib (2006) RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ... Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=4549
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic Jurnal i-lib UGM
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
description The Extra High Voltage Transmission Line (EHVTL) which was construction in the populated area creates significant implication in psychological impact to the people. It must be due to the rumor that the non-ionizing electromagnetic radiation causes some problem in the surrounding people's health. In order to confirm the non-ionizing radiation impact on the people, the research has been conducted around of EHVTL, which is located in Bowan Village, District Delanggu, Klaten, Central Java, Indonesia. A detector for non-ionizing radiation were developed and used accordingly. The simulation results and the measurement results show that the maximum intensity of electrics field levels were 0.014kV/m. These levels are significantly lower than the maximum level of the International Standard for Non-Ionizing Radiation Level, i.e., 10 kV/m. Average the maximum intensity of magnetic field levels were 0.650mT, which are higher than the maximum level of the International Standard for Non-Ionizing Radiation Level, i.e., O.5mT. This detector for non-ionizing radiation can as well be used by the designers and engineers who work in the electric energy transmission field. Keywords: non-ionizing radiation, electromagnetic, electrics field, magnetisms fiel
format Article
NonPeerReviewed
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
title RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
title_short RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
title_full RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
title_fullStr RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
title_full_unstemmed RancanganmBangunmdetektor Radiasi Nonpengion Di Sekitar Saluran Udara Tegangan Eksra Tinggi(Sutet) (Design and Development of Non-Ionizing Radiation Detector ...
title_sort rancanganmbangunmdetektor radiasi nonpengion di sekitar saluran udara tegangan eksra tinggi(sutet) (design and development of non-ionizing radiation detector ...
publisher [Yogyakarta] : Laboratorium aekologi Fak. Biologi UGM
publishDate 2006
url https://repository.ugm.ac.id/21678/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=4549
_version_ 1681217879159078912