Pengaruh Posisi Titik Rekombinasi Terhadap Unjuk Kerja GLCC Metering Loop
This paper presents performance of a gas-liquid cylindrical cyclone separator (GLCC metering loop). The effects of outlet position on the GLCC metering loop separator have been studied experimentally. New experimental data were collected utilizing a 7.62cm ID, 150cm high GLCC, which has a single inl...
Saved in:
主要作者: | |
---|---|
格式: | Article NonPeerReviewed |
出版: |
[Yogyakarta] : Universitas Gadjah Mada
2003
|
主題: | |
在線閱讀: | https://repository.ugm.ac.id/23530/ http://i-lib.ugm.ac.id/jurnal/download.php?dataId=6480 |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
機構: | Universitas Gadjah Mada |
總結: | This paper presents performance of a gas-liquid cylindrical cyclone separator (GLCC metering loop). The effects of outlet position on the GLCC metering loop separator have been studied experimentally. New experimental data were collected utilizing a 7.62cm ID, 150cm high GLCC, which has a single inlet system. Parameters investigated, included six different positions of a recombination point (H=80, 60, 40, 20, 0, and -20cm from the inlet plane). The results were presented in graphical form of the equilibrium liquid level (Leq) as a function of the superficial gas velocity (vsg). Leq increased with the recombination position. A good agreement was obtained between the theory and the experiments.
Keywords : GLCC metering loop, recombination point, separator |
---|