Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples

A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The...

Full description

Saved in:
Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2008
Subjects:
Online Access:https://repository.ugm.ac.id/27326/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.27326
record_format dspace
spelling id-ugm-repo.273262014-06-18T00:25:05Z https://repository.ugm.ac.id/27326/ Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples Perpustakaan UGM, i-lib Jurnal i-lib UGM A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HN03, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration ran?e of for 0.03-1. 1 /1g mC' for Nf+ , 0.03 1.0 ~g mC' for cif+, 0.02-1.0/1g mC' for Pb2+ , 0.02-1.0/1g mC' for Co +,0.02-1.1 /1g mC' Zn2+ and 0.05-1.3 /1g mC for Cer. The detection limits of each element are expressed as the amount of analytes in pg mC' giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Nr , cif+, Pb2+ , C02+,Zn2+ and CcP. The ability of method for repeatable recove~ of trace ion are 99.9, 98.7, 99.2, 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4, 1.2, 1.4, 1.7 and 1.4 for Nr , Cu2+, Pb + , C02+, Zn2+ and Cer. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable. Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DSDP), Activated Carbon [Yogyakarta] : Universitas Gadjah Mada 2008 Article NonPeerReviewed Perpustakaan UGM, i-lib (2008) Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic Jurnal i-lib UGM
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
description A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HN03, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration ran?e of for 0.03-1. 1 /1g mC' for Nf+ , 0.03 1.0 ~g mC' for cif+, 0.02-1.0/1g mC' for Pb2+ , 0.02-1.0/1g mC' for Co +,0.02-1.1 /1g mC' Zn2+ and 0.05-1.3 /1g mC for Cer. The detection limits of each element are expressed as the amount of analytes in pg mC' giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Nr , cif+, Pb2+ , C02+,Zn2+ and CcP. The ability of method for repeatable recove~ of trace ion are 99.9, 98.7, 99.2, 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4, 1.2, 1.4, 1.7 and 1.4 for Nr , Cu2+, Pb + , C02+, Zn2+ and Cer. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable. Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DSDP), Activated Carbon
format Article
NonPeerReviewed
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
title Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
title_short Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
title_full Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
title_fullStr Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
title_full_unstemmed Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
title_sort pre-concentration and determination of heavy metals on modified activated carbon in real samples
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2008
url https://repository.ugm.ac.id/27326/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380
_version_ 1681218938834255872