Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples
A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The...
Saved in:
Main Author: | |
---|---|
Format: | Article NonPeerReviewed |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2008
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/27326/ http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
id |
id-ugm-repo.27326 |
---|---|
record_format |
dspace |
spelling |
id-ugm-repo.273262014-06-18T00:25:05Z https://repository.ugm.ac.id/27326/ Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples Perpustakaan UGM, i-lib Jurnal i-lib UGM A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HN03, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration ran?e of for 0.03-1. 1 /1g mC' for Nf+ , 0.03 1.0 ~g mC' for cif+, 0.02-1.0/1g mC' for Pb2+ , 0.02-1.0/1g mC' for Co +,0.02-1.1 /1g mC' Zn2+ and 0.05-1.3 /1g mC for Cer. The detection limits of each element are expressed as the amount of analytes in pg mC' giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Nr , cif+, Pb2+ , C02+,Zn2+ and CcP. The ability of method for repeatable recove~ of trace ion are 99.9, 98.7, 99.2, 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4, 1.2, 1.4, 1.7 and 1.4 for Nr , Cu2+, Pb + , C02+, Zn2+ and Cer. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable. Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DSDP), Activated Carbon [Yogyakarta] : Universitas Gadjah Mada 2008 Article NonPeerReviewed Perpustakaan UGM, i-lib (2008) Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380 |
institution |
Universitas Gadjah Mada |
building |
UGM Library |
country |
Indonesia |
collection |
Repository Civitas UGM |
topic |
Jurnal i-lib UGM |
spellingShingle |
Jurnal i-lib UGM Perpustakaan UGM, i-lib Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
description |
A sensitive' and simple method for the simultaneous pre-concentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by N, N'-diacetyl-4-bromo-2, 6-di (aminomethyl) phenol (DSDP) loaded on activated carbon. The metals content on the complexes are then eluted using 6mL 4M HN03, which are detected by AAS at resonance line. In this procedure, minerals such as Ni, Cu, Co, Pb Zn and Cd can be analyzed in one run by caring out the simultaneous separation and quantification of
them. At optimum condition the response are linear over concentration ran?e of for 0.03-1. 1 /1g mC' for Nf+ , 0.03
1.0 ~g mC' for cif+, 0.02-1.0/1g mC' for Pb2+ , 0.02-1.0/1g mC' for Co +,0.02-1.1 /1g mC' Zn2+ and 0.05-1.3 /1g
mC for Cer. The detection limits of each element are expressed as the amount of analytes in pg mC' giving a signal to noise ratio of 3 are equal to 2.5, 2.4, 1.6, 2.4, 1.9 and 2.1 for Nr , cif+, Pb2+ , C02+,Zn2+ and CcP. The
ability of method for repeatable recove~ of trace ion are 99.9, 98.7, 99.2, 98.7, 98.5and 95.6 with R.S.D of 1.3, 1.4,
1.2, 1.4, 1.7 and 1.4 for Nr , Cu2+, Pb + , C02+, Zn2+ and Cer. The method has been successfully applied for these metals content evaluation in some real samples including natural water and vegetable.
Keywords: Heavy Metals, N, N'-diacetyl-4-bromo-2,6-di(aminomethyl) phenol (DSDP), Activated Carbon |
format |
Article NonPeerReviewed |
author |
Perpustakaan UGM, i-lib |
author_facet |
Perpustakaan UGM, i-lib |
author_sort |
Perpustakaan UGM, i-lib |
title |
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
title_short |
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
title_full |
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
title_fullStr |
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
title_full_unstemmed |
Pre-concentration and Determination of Heavy Metals on Modified Activated Carbon in Real Samples |
title_sort |
pre-concentration and determination of heavy metals on modified activated carbon in real samples |
publisher |
[Yogyakarta] : Universitas Gadjah Mada |
publishDate |
2008 |
url |
https://repository.ugm.ac.id/27326/ http://i-lib.ugm.ac.id/jurnal/download.php?dataId=10380 |
_version_ |
1681218938834255872 |