MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen

ABSTRACT At a few this last years, measurement concentration of dissolved inorganic nutrient is has rapidlyed grow by using various methods. But method anything applied must based on at formation of indicator end of measurement amonia, nitrite, nitrate, orthophosphate and silicate. At measurement of...

Full description

Saved in:
Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2008
Subjects:
Online Access:https://repository.ugm.ac.id/27996/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11059
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.27996
record_format dspace
spelling id-ugm-repo.279962014-06-18T00:24:58Z https://repository.ugm.ac.id/27996/ MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT At a few this last years, measurement concentration of dissolved inorganic nutrient is has rapidlyed grow by using various methods. But method anything applied must based on at formation of indicator end of measurement amonia, nitrite, nitrate, orthophosphate and silicate. At measurement of amonia its indicator is formation of blue indophenol, nitriteformation of pink azo, nitrate formation of yellow colored solution, orthophosphate formation of blue molybdenum, and silicate based on formation of yellows silicomolibdate. The intensity of color that is highly dependent on the concentration of each element. Measurement of amonia blue indophenol intensity perfected concentration in the range 0.206-0.396 mg/L. Measurement nitrite the formation of a pink azo easy imperfect because its low concentration. Intensity measurements nitrate solution yellow perfect concentration in the range 0.128-0.989 mg/L. Measurement of imperfect blue molybdenum intensity orthophosphate because its low concentration. While measuring the formation silicate of yellow silicomolibdate perfect concentration on the range 10.573-26.470 mg/L. As a whole from result of measurement is obtained chemical composition of dissolved inorganic nutrient in euphotic zone the Banten bay is more predominated by silicate 97.27%, nitrate 1.84%, amonia 0.49%, orthophosphate0.20%, and nitrite 0.18%. Keywords: blue indophenol,pink azo, yellow solution, blue molybdenum,yellow silicomolibdat [Yogyakarta] : Universitas Gadjah Mada 2008 Article NonPeerReviewed Perpustakaan UGM, i-lib (2008) MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11059
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic Jurnal i-lib UGM
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
description ABSTRACT At a few this last years, measurement concentration of dissolved inorganic nutrient is has rapidlyed grow by using various methods. But method anything applied must based on at formation of indicator end of measurement amonia, nitrite, nitrate, orthophosphate and silicate. At measurement of amonia its indicator is formation of blue indophenol, nitriteformation of pink azo, nitrate formation of yellow colored solution, orthophosphate formation of blue molybdenum, and silicate based on formation of yellows silicomolibdate. The intensity of color that is highly dependent on the concentration of each element. Measurement of amonia blue indophenol intensity perfected concentration in the range 0.206-0.396 mg/L. Measurement nitrite the formation of a pink azo easy imperfect because its low concentration. Intensity measurements nitrate solution yellow perfect concentration in the range 0.128-0.989 mg/L. Measurement of imperfect blue molybdenum intensity orthophosphate because its low concentration. While measuring the formation silicate of yellow silicomolibdate perfect concentration on the range 10.573-26.470 mg/L. As a whole from result of measurement is obtained chemical composition of dissolved inorganic nutrient in euphotic zone the Banten bay is more predominated by silicate 97.27%, nitrate 1.84%, amonia 0.49%, orthophosphate0.20%, and nitrite 0.18%. Keywords: blue indophenol,pink azo, yellow solution, blue molybdenum,yellow silicomolibdat
format Article
NonPeerReviewed
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
title MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
title_short MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
title_full MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
title_fullStr MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
title_full_unstemmed MEASUREMENT OF DISSOLVED INORGANIC NUTRIENT IN EUPHOTIC ZONE THE BANTEN BAY Pengukuran Hutr/en Inorgan/k Terlarut d/ Zona Eufotik Pera/ran Teluk Santen
title_sort measurement of dissolved inorganic nutrient in euphotic zone the banten bay pengukuran hutr/en inorgan/k terlarut d/ zona eufotik pera/ran teluk santen
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2008
url https://repository.ugm.ac.id/27996/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11059
_version_ 1681219064563761152