USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN

ABSTRACT Regarding a new regulation from Indonesia FDA (Badan POM-RI), all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing)has to be performed to the people that represented of population to which the drug to be admin...

Full description

Saved in:
Bibliographic Details
Main Author: Perpustakaan UGM, i-lib
Format: Article NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2010
Subjects:
Online Access:https://repository.ugm.ac.id/28070/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11133
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.28070
record_format dspace
spelling id-ugm-repo.280702014-06-18T00:24:17Z https://repository.ugm.ac.id/28070/ USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN Perpustakaan UGM, i-lib Jurnal i-lib UGM ABSTRACT Regarding a new regulation from Indonesia FDA (Badan POM-RI), all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing)has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bioanalytical method for certain drug target and group of population. This research report specific validation of bioanalysis of Rifampicin in Indonesian serum specimen in or.der to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 x 4.6 mm i.d., 5.J.lm),with a mobile phase composed of KH2P04 10 mM-Acetonitrile (40:60, v/v) and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ) was 0.06 J.lg/mLwith dynamic range up to 20 J.lg/mL (R>0.990). Precision of the method was very good with coefficient of variance (CV) 0.58 [Yogyakarta] : Universitas Gadjah Mada 2010 Article NonPeerReviewed Perpustakaan UGM, i-lib (2010) USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN. Jurnal i-lib UGM. http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11133
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic Jurnal i-lib UGM
spellingShingle Jurnal i-lib UGM
Perpustakaan UGM, i-lib
USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
description ABSTRACT Regarding a new regulation from Indonesia FDA (Badan POM-RI), all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing)has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bioanalytical method for certain drug target and group of population. This research report specific validation of bioanalysis of Rifampicin in Indonesian serum specimen in or.der to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 x 4.6 mm i.d., 5.J.lm),with a mobile phase composed of KH2P04 10 mM-Acetonitrile (40:60, v/v) and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ) was 0.06 J.lg/mLwith dynamic range up to 20 J.lg/mL (R>0.990). Precision of the method was very good with coefficient of variance (CV) 0.58
format Article
NonPeerReviewed
author Perpustakaan UGM, i-lib
author_facet Perpustakaan UGM, i-lib
author_sort Perpustakaan UGM, i-lib
title USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
title_short USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
title_full USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
title_fullStr USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
title_full_unstemmed USFDA-GUIDELINEBASED VALIDATION OF TESTING METHODFOR RIFAMPICIN IN INDONESIANSERUM SPECIMEN
title_sort usfda-guidelinebased validation of testing methodfor rifampicin in indonesianserum specimen
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2010
url https://repository.ugm.ac.id/28070/
http://i-lib.ugm.ac.id/jurnal/download.php?dataId=11133
_version_ 1681219078589513728