UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
Background. Combination of gypsum and carbonated hydroxyapatite has been shown to improve the bone healing process since gypsum that has been applied in many clinical practice may fill irregular and small defect and evoke minimal inflammatory response while carbonated hydroxyapatite has excellent os...
Saved in:
Main Authors: | , |
---|---|
Format: | Theses and Dissertations NonPeerReviewed |
Published: |
[Yogyakarta] : Universitas Gadjah Mada
2011
|
Subjects: | |
Online Access: | https://repository.ugm.ac.id/88563/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
id |
id-ugm-repo.88563 |
---|---|
record_format |
dspace |
spelling |
id-ugm-repo.885632014-08-20T02:50:55Z https://repository.ugm.ac.id/88563/ UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus) , DYAH LISTYARIFAH , dr. Rina Susilowati, Ph.D. ETD Background. Combination of gypsum and carbonated hydroxyapatite has been shown to improve the bone healing process since gypsum that has been applied in many clinical practice may fill irregular and small defect and evoke minimal inflammatory response while carbonated hydroxyapatite has excellent osteoconductivity and good resorbtion rate. Soft tissue biocompatibility test is required prior to clinical application of bone substitutes since the material also contact to the soft tissue upon application and soft tissue response are more severe than the bone tissue response. Objective. The aim of this study was to evaluate histocompatibility of gypsum compare to combination gypsum with carbonated hydroxyapatite in subcutaneous tissue. Materials and Methods. Disk of gypsum and gypsum with carbonated hydroxyapatite were made with diameter of 6 mm and 0.8 mm thick. Twenty five healthy 3.5 � 4 month male Wistar rats were used. Each rat received one disk of gypsum and one disk of gypsum with carbonated hydroxyapatite in paravertebral subcutaneous tissue. Five rats were sacrificed each after 6 h, 5, 7, 14, and 21 days. 10 um paraffin sections of the implant and the tissue surround it were stained with Hematoxylin Eosin. Histological evaluation and scoring with a histological grading scale for soft-tissue implants were performed. A two-way ANOVA were used to analyze the results of the histomorphometrical analysis. The level of significance was set at P<0.05. Results and discussions. Acute inflammatory cells were found in 6 h, 5 and 7 d groups at similar number in both material. Chronic inflammatory cells such as foreign giant cells and lymphocytes as well as capsule were observed in day 7,14,21. There are no significant different (p>0.05) of histomorphometrics score between gypsum and gypsum with carbonated hydroxyapatite in each implantation periods (7, 14, and 21 days). Conclutions. Gypsum and combination between gypsum with carbonated hydroxyapatit e have the same soft tissue histocompatibility level [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , DYAH LISTYARIFAH and , dr. Rina Susilowati, Ph.D. (2011) UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993 |
institution |
Universitas Gadjah Mada |
building |
UGM Library |
country |
Indonesia |
collection |
Repository Civitas UGM |
topic |
ETD |
spellingShingle |
ETD , DYAH LISTYARIFAH , dr. Rina Susilowati, Ph.D. UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus) |
description |
Background. Combination of gypsum and carbonated hydroxyapatite has been
shown to improve the bone healing process since gypsum that has been applied in
many clinical practice may fill irregular and small defect and evoke minimal
inflammatory response while carbonated hydroxyapatite has excellent
osteoconductivity and good resorbtion rate. Soft tissue biocompatibility test is
required prior to clinical application of bone substitutes since the material also
contact to the soft tissue upon application and soft tissue response are more severe
than the bone tissue response.
Objective. The aim of this study was to evaluate histocompatibility of gypsum
compare to combination gypsum with carbonated hydroxyapatite in subcutaneous
tissue.
Materials and Methods. Disk of gypsum and gypsum with carbonated
hydroxyapatite were made with diameter of 6 mm and 0.8 mm thick. Twenty five
healthy 3.5 � 4 month male Wistar rats were used. Each rat received one disk of
gypsum and one disk of gypsum with carbonated hydroxyapatite in paravertebral
subcutaneous tissue. Five rats were sacrificed each after 6 h, 5, 7, 14, and 21 days.
10 um paraffin sections of the implant and the tissue surround it were stained with
Hematoxylin Eosin. Histological evaluation and scoring with a histological
grading scale for soft-tissue implants were performed. A two-way ANOVA were
used to analyze the results of the histomorphometrical analysis. The level of
significance was set at P<0.05.
Results and discussions. Acute inflammatory cells were found in 6 h, 5 and 7 d
groups at similar number in both material. Chronic inflammatory cells such as
foreign giant cells and lymphocytes as well as capsule were observed in day
7,14,21. There are no significant different (p>0.05) of histomorphometrics score
between gypsum and gypsum with carbonated hydroxyapatite in each
implantation periods (7, 14, and 21 days).
Conclutions. Gypsum and combination between gypsum with carbonated
hydroxyapatit e have the same soft tissue histocompatibility level |
format |
Theses and Dissertations NonPeerReviewed |
author |
, DYAH LISTYARIFAH , dr. Rina Susilowati, Ph.D. |
author_facet |
, DYAH LISTYARIFAH , dr. Rina Susilowati, Ph.D. |
author_sort |
, DYAH LISTYARIFAH |
title |
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG
GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT
PADA JARINGAN LUNAK
(Kajian In Vivo pada Sub Kutan Tikus) |
title_short |
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG
GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT
PADA JARINGAN LUNAK
(Kajian In Vivo pada Sub Kutan Tikus) |
title_full |
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG
GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT
PADA JARINGAN LUNAK
(Kajian In Vivo pada Sub Kutan Tikus) |
title_fullStr |
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG
GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT
PADA JARINGAN LUNAK
(Kajian In Vivo pada Sub Kutan Tikus) |
title_full_unstemmed |
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG
GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT
PADA JARINGAN LUNAK
(Kajian In Vivo pada Sub Kutan Tikus) |
title_sort |
uji histokompatibilitas bahan substitusi tulang
gipsum dan kombinasi gipsum dengan karbonat apatit
pada jaringan lunak
(kajian in vivo pada sub kutan tikus) |
publisher |
[Yogyakarta] : Universitas Gadjah Mada |
publishDate |
2011 |
url |
https://repository.ugm.ac.id/88563/ http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993 |
_version_ |
1681228611716120576 |