UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)

Background. Combination of gypsum and carbonated hydroxyapatite has been shown to improve the bone healing process since gypsum that has been applied in many clinical practice may fill irregular and small defect and evoke minimal inflammatory response while carbonated hydroxyapatite has excellent os...

Full description

Saved in:
Bibliographic Details
Main Authors: , DYAH LISTYARIFAH, , dr. Rina Susilowati, Ph.D.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/88563/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.88563
record_format dspace
spelling id-ugm-repo.885632014-08-20T02:50:55Z https://repository.ugm.ac.id/88563/ UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus) , DYAH LISTYARIFAH , dr. Rina Susilowati, Ph.D. ETD Background. Combination of gypsum and carbonated hydroxyapatite has been shown to improve the bone healing process since gypsum that has been applied in many clinical practice may fill irregular and small defect and evoke minimal inflammatory response while carbonated hydroxyapatite has excellent osteoconductivity and good resorbtion rate. Soft tissue biocompatibility test is required prior to clinical application of bone substitutes since the material also contact to the soft tissue upon application and soft tissue response are more severe than the bone tissue response. Objective. The aim of this study was to evaluate histocompatibility of gypsum compare to combination gypsum with carbonated hydroxyapatite in subcutaneous tissue. Materials and Methods. Disk of gypsum and gypsum with carbonated hydroxyapatite were made with diameter of 6 mm and 0.8 mm thick. Twenty five healthy 3.5 � 4 month male Wistar rats were used. Each rat received one disk of gypsum and one disk of gypsum with carbonated hydroxyapatite in paravertebral subcutaneous tissue. Five rats were sacrificed each after 6 h, 5, 7, 14, and 21 days. 10 um paraffin sections of the implant and the tissue surround it were stained with Hematoxylin Eosin. Histological evaluation and scoring with a histological grading scale for soft-tissue implants were performed. A two-way ANOVA were used to analyze the results of the histomorphometrical analysis. The level of significance was set at P<0.05. Results and discussions. Acute inflammatory cells were found in 6 h, 5 and 7 d groups at similar number in both material. Chronic inflammatory cells such as foreign giant cells and lymphocytes as well as capsule were observed in day 7,14,21. There are no significant different (p>0.05) of histomorphometrics score between gypsum and gypsum with carbonated hydroxyapatite in each implantation periods (7, 14, and 21 days). Conclutions. Gypsum and combination between gypsum with carbonated hydroxyapatit e have the same soft tissue histocompatibility level [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , DYAH LISTYARIFAH and , dr. Rina Susilowati, Ph.D. (2011) UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus). UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, DYAH LISTYARIFAH
, dr. Rina Susilowati, Ph.D.
UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
description Background. Combination of gypsum and carbonated hydroxyapatite has been shown to improve the bone healing process since gypsum that has been applied in many clinical practice may fill irregular and small defect and evoke minimal inflammatory response while carbonated hydroxyapatite has excellent osteoconductivity and good resorbtion rate. Soft tissue biocompatibility test is required prior to clinical application of bone substitutes since the material also contact to the soft tissue upon application and soft tissue response are more severe than the bone tissue response. Objective. The aim of this study was to evaluate histocompatibility of gypsum compare to combination gypsum with carbonated hydroxyapatite in subcutaneous tissue. Materials and Methods. Disk of gypsum and gypsum with carbonated hydroxyapatite were made with diameter of 6 mm and 0.8 mm thick. Twenty five healthy 3.5 � 4 month male Wistar rats were used. Each rat received one disk of gypsum and one disk of gypsum with carbonated hydroxyapatite in paravertebral subcutaneous tissue. Five rats were sacrificed each after 6 h, 5, 7, 14, and 21 days. 10 um paraffin sections of the implant and the tissue surround it were stained with Hematoxylin Eosin. Histological evaluation and scoring with a histological grading scale for soft-tissue implants were performed. A two-way ANOVA were used to analyze the results of the histomorphometrical analysis. The level of significance was set at P<0.05. Results and discussions. Acute inflammatory cells were found in 6 h, 5 and 7 d groups at similar number in both material. Chronic inflammatory cells such as foreign giant cells and lymphocytes as well as capsule were observed in day 7,14,21. There are no significant different (p>0.05) of histomorphometrics score between gypsum and gypsum with carbonated hydroxyapatite in each implantation periods (7, 14, and 21 days). Conclutions. Gypsum and combination between gypsum with carbonated hydroxyapatit e have the same soft tissue histocompatibility level
format Theses and Dissertations
NonPeerReviewed
author , DYAH LISTYARIFAH
, dr. Rina Susilowati, Ph.D.
author_facet , DYAH LISTYARIFAH
, dr. Rina Susilowati, Ph.D.
author_sort , DYAH LISTYARIFAH
title UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
title_short UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
title_full UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
title_fullStr UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
title_full_unstemmed UJI HISTOKOMPATIBILITAS BAHAN SUBSTITUSI TULANG GIPSUM DAN KOMBINASI GIPSUM DENGAN KARBONAT APATIT PADA JARINGAN LUNAK (Kajian In Vivo pada Sub Kutan Tikus)
title_sort uji histokompatibilitas bahan substitusi tulang gipsum dan kombinasi gipsum dengan karbonat apatit pada jaringan lunak (kajian in vivo pada sub kutan tikus)
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2011
url https://repository.ugm.ac.id/88563/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=50993
_version_ 1681228611716120576