STUDI SISTEM MONITORING JARINGAN PDAM DAN RANCANG BANGUN MONITORING PLTMH PADA BAK PELEPAS TEKAN IV PDAM KOTA MALANG

Micro hydro as one of the current renewable energy power plants can be used as an alternative energy for areas that have not been powered by PLN. The constructiom does not always require a high cost, one of the solution is to utilize the Water Release Chamber owned by PDAM. In this research takes pl...

Full description

Saved in:
Bibliographic Details
Main Authors: , Raden Roro Retno Dwi Chyntia Oetami, , Ahmad Agus Setiawan, ST., M.Sc., Ph.D.
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/89601/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=51461
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
Description
Summary:Micro hydro as one of the current renewable energy power plants can be used as an alternative energy for areas that have not been powered by PLN. The constructiom does not always require a high cost, one of the solution is to utilize the Water Release Chamber owned by PDAM. In this research takes place on Water Release Chamber IV PDAM Malang that has the potential of water until 100 l /sec. In addition to micro hydro development in terms of mechanical and electrical with the information and control technology developed at this time should be used for various things that can be used in assisting our daily tasks. Monitoring a data measurement as real time and data acquisition can be used to increase renewable energy sources, monitoring the efficiency, security and sends the data using a intercommunication system. In this study created a monitoring system to monitor and collect data in real time from the output of the generator at the Microhydro in BPT IV. Design of the controller hardware using a series of AT Mega 8, voltage sensors, current sensors, and frequency sensors while to display and design of software using Visual Basic 6. Next on the display will show the value of current, voltage, frequency, power consumption and load graphical display. The results from the use of the load can be stored in table form and can be saved through Microsoft Excel. Camera used to monitoring the of the Microhydro equipments and the tub press release situation. The results of testing in the laboratory used to determine the suitability of the measurement with the measuring instrument with the display on a monitoring system with a value of 2.3% error voltage sensor, 2,5 % current sensor and sensor frequency of 0.4%. This indicates that this monitoring system has been able to read well the measurement results. But for the transmitter and receiver module is still not working properly because at the time of the test the data transmission, receivers module can not receive the perfect data that sent by the transmitter.