PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer)
<div align="justify">Blood contamination will influence the quality of root canal obturation. The aims of this research was to know the influence of blood contamination on root canal apical leakage using three kinds of root canal sealer namely zinc oxide eugenol, resin and calcium hy...
Saved in:
Main Author: | |
---|---|
Format: | Article NonPeerReviewed |
Published: |
[Yogyakarta] : Ikatan Konservasi Gigi Indonesia
2011
|
Online Access: | https://repository.ugm.ac.id/94984/ http://repository.ugm.ac.id/digitasi/index.php?module=cari_hasil_full&idbuku=2793 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universitas Gadjah Mada |
id |
id-ugm-repo.94984 |
---|---|
record_format |
dspace |
spelling |
id-ugm-repo.949842014-11-28T07:34:41Z https://repository.ugm.ac.id/94984/ PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) , Ema Mulyawati <div align="justify">Blood contamination will influence the quality of root canal obturation. The aims of this research was to know the influence of blood contamination on root canal apical leakage using three kinds of root canal sealer namely zinc oxide eugenol, resin and calcium hydroxide. Forty two anterior teeth were prepared and divided into six groups: AI, BI, CI, A2, B2 and C2. Group A filled with zinc oxide eugenol sealer, group B with resin sealer and group C with calcium hydroxide sealer. Group AI,BI and CI were obturated under dry condition while group A2,B2 and C2 were contaminated by blood. All of them were gutta percha obturated using single cone methodfollowed by composite resinfilling. After that, all specimens were incubatedfor 28 days, 37" [Yogyakarta] : Ikatan Konservasi Gigi Indonesia 2011 Article NonPeerReviewed , Ema Mulyawati (2011) PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer). text. http://repository.ugm.ac.id/digitasi/index.php?module=cari_hasil_full&idbuku=2793 |
institution |
Universitas Gadjah Mada |
building |
UGM Library |
country |
Indonesia |
collection |
Repository Civitas UGM |
description |
<div align="justify">Blood contamination will influence the quality of root canal obturation. The aims of this research was to know the influence of blood contamination on root canal apical leakage using three kinds of root canal sealer namely zinc oxide eugenol, resin and calcium hydroxide. Forty two anterior teeth were prepared and divided into six groups: AI, BI, CI, A2, B2 and C2. Group A filled with zinc oxide eugenol sealer, group B with resin sealer and group C with calcium hydroxide sealer. Group AI,BI and CI were obturated under dry condition while group A2,B2 and C2 were contaminated by blood. All of them were gutta percha obturated using single cone methodfollowed by composite resinfilling. After that, all specimens were incubatedfor 28 days, 37" |
format |
Article NonPeerReviewed |
author |
, Ema Mulyawati |
spellingShingle |
, Ema Mulyawati PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
author_facet |
, Ema Mulyawati |
author_sort |
, Ema Mulyawati |
title |
PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
title_short |
PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
title_full |
PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
title_fullStr |
PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
title_full_unstemmed |
PENGARUH KONTAMINASI DARAH TERHADAPKEBOCORANAPIKALPADAOBTURASI . SALURANAKAR MENGGUNAKANTIGA JENIS SILER YANG BERBEDA ( The influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
title_sort |
pengaruh kontaminasi darah terhadapkebocoranapikalpadaobturasi . saluranakar menggunakantiga jenis siler yang berbeda ( the influence of blood contamination on apical leakage of root canal obturation using three kinds of sealer) |
publisher |
[Yogyakarta] : Ikatan Konservasi Gigi Indonesia |
publishDate |
2011 |
url |
https://repository.ugm.ac.id/94984/ http://repository.ugm.ac.id/digitasi/index.php?module=cari_hasil_full&idbuku=2793 |
_version_ |
1681229735626014720 |