PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY

Comparative on image quality has been done for digital fluoroscopic radiography a frame grabber (DFR) and by a computed radiography (CR) and its relation to the entrace skin exposure (ESE) value. ESE measurement was using free in air method by a personal alarm dosimeter. The phantom object of antrom...

Full description

Saved in:
Bibliographic Details
Main Authors: , SITI DARYATI, , Dr. Gede Bayu Suparta
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2011
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/97388/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=53651
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.97388
record_format dspace
spelling id-ugm-repo.973882016-03-04T08:50:24Z https://repository.ugm.ac.id/97388/ PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY , SITI DARYATI , Dr. Gede Bayu Suparta ETD Comparative on image quality has been done for digital fluoroscopic radiography a frame grabber (DFR) and by a computed radiography (CR) and its relation to the entrace skin exposure (ESE) value. ESE measurement was using free in air method by a personal alarm dosimeter. The phantom object of antromorphic phantom pelvis was used. Digitization process was using a frame grabber that was connected to the output of a fluoroscopy imaging system. Results from digital fluoroscopy using DrGrabber was compared to the results from CR. Contrast analysis based on histogram and line profile was using ImageJ software. The ESE value for CR and digitized by the frame grabber increased as the voltage increased. The ESE value of CR lowest 54.35 ± 2 and highest 111.36 ± 2 while The ESE value of DFR lowest 17.48 ± 1 and highest 117.45 ± 2. The ESE value of DFR (quartil 1 = 30,60 mR, quartil 2 = 49,60 mR and quartil 3 = 78,01 mR)was lower than the ESE value of CR (quartil 1 = 61,10 mR, quartil 2 = 74,69 mR and quartil 3 = 90,55 mR). These results are lower than the quartil 1, 2, dan 3 of ESE value for abdomen AP diagnostic of AAPM Report No.31 (2005). The voltage increase in CR provided no contrast difference based on color gradation, while a better contrast difference are obtained by DFR. [Yogyakarta] : Universitas Gadjah Mada 2011 Thesis NonPeerReviewed , SITI DARYATI and , Dr. Gede Bayu Suparta (2011) PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=53651
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, SITI DARYATI
, Dr. Gede Bayu Suparta
PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
description Comparative on image quality has been done for digital fluoroscopic radiography a frame grabber (DFR) and by a computed radiography (CR) and its relation to the entrace skin exposure (ESE) value. ESE measurement was using free in air method by a personal alarm dosimeter. The phantom object of antromorphic phantom pelvis was used. Digitization process was using a frame grabber that was connected to the output of a fluoroscopy imaging system. Results from digital fluoroscopy using DrGrabber was compared to the results from CR. Contrast analysis based on histogram and line profile was using ImageJ software. The ESE value for CR and digitized by the frame grabber increased as the voltage increased. The ESE value of CR lowest 54.35 ± 2 and highest 111.36 ± 2 while The ESE value of DFR lowest 17.48 ± 1 and highest 117.45 ± 2. The ESE value of DFR (quartil 1 = 30,60 mR, quartil 2 = 49,60 mR and quartil 3 = 78,01 mR)was lower than the ESE value of CR (quartil 1 = 61,10 mR, quartil 2 = 74,69 mR and quartil 3 = 90,55 mR). These results are lower than the quartil 1, 2, dan 3 of ESE value for abdomen AP diagnostic of AAPM Report No.31 (2005). The voltage increase in CR provided no contrast difference based on color gradation, while a better contrast difference are obtained by DFR.
format Theses and Dissertations
NonPeerReviewed
author , SITI DARYATI
, Dr. Gede Bayu Suparta
author_facet , SITI DARYATI
, Dr. Gede Bayu Suparta
author_sort , SITI DARYATI
title PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
title_short PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
title_full PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
title_fullStr PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
title_full_unstemmed PERBANDINGAN KUALITAS CITRA RADIOGRAFI DIGITAL ANTARA HASIL DIGITISASI FRAME GRABBER DAN COMPUTED RADIOGRAPHY
title_sort perbandingan kualitas citra radiografi digital antara hasil digitisasi frame grabber dan computed radiography
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2011
url https://repository.ugm.ac.id/97388/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=53651
_version_ 1681230164201046016