PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR

The loss due to collapsing structure includes not only materials but may also take lives. In the case of structure function changing that may cause increasing loads, it is required to put efforts in strengthening the structure elements in order to increase the capacity and hence to avoid the possibi...

Full description

Saved in:
Bibliographic Details
Main Authors: , YANUAR HARYANTO, , Prof. Ir. Iman Satyarno, ME, Ph.D
Format: Theses and Dissertations NonPeerReviewed
Published: [Yogyakarta] : Universitas Gadjah Mada 2012
Subjects:
ETD
Online Access:https://repository.ugm.ac.id/97885/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54059
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Gadjah Mada
id id-ugm-repo.97885
record_format dspace
spelling id-ugm-repo.978852016-03-04T08:49:26Z https://repository.ugm.ac.id/97885/ PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR , YANUAR HARYANTO , Prof. Ir. Iman Satyarno, ME, Ph.D, ETD The loss due to collapsing structure includes not only materials but may also take lives. In the case of structure function changing that may cause increasing loads, it is required to put efforts in strengthening the structure elements in order to increase the capacity and hence to avoid the possibility of collapsing. The objective of this research was to study the behavior of T-sectional reinforced concrete beam strengthened in the negative moment region by wire rope and mortar composite. The test was carried out to three T-sectional beams: without wire rope reinforcement (BK), with 2 wire rope reinforcements (BP1), and with 4 wire rope (BP2) reinforcements. The type of wire rope was Independent Wire Rope Core (IWRC) with 10 mm diameter. The testing method used was two points static loading with flens positions below (the flens part experienced tensile stress). Results showed that the maximum load carrying capacity of BP1 and BP2 specimens increased by ratios of 1.59 and 2.03 to the BK specimen respectively. However, the increase was achieved after the development and propagation of high cracking. Ductility of BP1 and BP2 specimens decreased by ratios of 0.62 and 0.36 to the BK specimen respectively. The initial stiffness of BP1 and BP2 increased by ratios of 1.09 and 1.08 to the BK specimen respective. The effective stiffness of BP1 and BP2 specimens decreased by respective ratios of 0.88 and 0.92 to the BK specimen. Stress occurred in the wire rope based on the analysis results of Response-2000 and the layer method have not reached 50% of the ultimate stress resulted from the preliminary tess. In general, unless improvement was given to the stiffness characteristics of the wire rope, its contribution would not become optimum. [Yogyakarta] : Universitas Gadjah Mada 2012 Thesis NonPeerReviewed , YANUAR HARYANTO and , Prof. Ir. Iman Satyarno, ME, Ph.D, (2012) PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR. UNSPECIFIED thesis, UNSPECIFIED. http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54059
institution Universitas Gadjah Mada
building UGM Library
country Indonesia
collection Repository Civitas UGM
topic ETD
spellingShingle ETD
, YANUAR HARYANTO
, Prof. Ir. Iman Satyarno, ME, Ph.D,
PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
description The loss due to collapsing structure includes not only materials but may also take lives. In the case of structure function changing that may cause increasing loads, it is required to put efforts in strengthening the structure elements in order to increase the capacity and hence to avoid the possibility of collapsing. The objective of this research was to study the behavior of T-sectional reinforced concrete beam strengthened in the negative moment region by wire rope and mortar composite. The test was carried out to three T-sectional beams: without wire rope reinforcement (BK), with 2 wire rope reinforcements (BP1), and with 4 wire rope (BP2) reinforcements. The type of wire rope was Independent Wire Rope Core (IWRC) with 10 mm diameter. The testing method used was two points static loading with flens positions below (the flens part experienced tensile stress). Results showed that the maximum load carrying capacity of BP1 and BP2 specimens increased by ratios of 1.59 and 2.03 to the BK specimen respectively. However, the increase was achieved after the development and propagation of high cracking. Ductility of BP1 and BP2 specimens decreased by ratios of 0.62 and 0.36 to the BK specimen respectively. The initial stiffness of BP1 and BP2 increased by ratios of 1.09 and 1.08 to the BK specimen respective. The effective stiffness of BP1 and BP2 specimens decreased by respective ratios of 0.88 and 0.92 to the BK specimen. Stress occurred in the wire rope based on the analysis results of Response-2000 and the layer method have not reached 50% of the ultimate stress resulted from the preliminary tess. In general, unless improvement was given to the stiffness characteristics of the wire rope, its contribution would not become optimum.
format Theses and Dissertations
NonPeerReviewed
author , YANUAR HARYANTO
, Prof. Ir. Iman Satyarno, ME, Ph.D,
author_facet , YANUAR HARYANTO
, Prof. Ir. Iman Satyarno, ME, Ph.D,
author_sort , YANUAR HARYANTO
title PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
title_short PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
title_full PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
title_fullStr PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
title_full_unstemmed PERILAKU LENTUR BALOK BETON BERTULANG TAMPANG T YANG DIPERKUAT PADA DAERAH MOMEN NEGATIF DENGAN WIRE ROPE DAN KOMPOSIT MORTAR
title_sort perilaku lentur balok beton bertulang tampang t yang diperkuat pada daerah momen negatif dengan wire rope dan komposit mortar
publisher [Yogyakarta] : Universitas Gadjah Mada
publishDate 2012
url https://repository.ugm.ac.id/97885/
http://etd.ugm.ac.id/index.php?mod=penelitian_detail&sub=PenelitianDetail&act=view&typ=html&buku_id=54059
_version_ 1681230254479245312