Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital

In this study, 6 MV photon beam of TrueBeam STx Varian LINAC with Flattening Filter Free (FFF) was simulated using PRIMO code. The depth dose profiles for various jaws open fields and cross beam profiles for various depths inside water phantom were determined using Monte Carlo (MC) simulation techni...

Full description

Saved in:
Bibliographic Details
Main Authors: M. Arif Efendi, Amporn Funsian, Thawat Chittrakarn, Tripob Bhongsuwan
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2017
Online Access:http://journalarticle.ukm.my/11365/1/08%20M.%20Arif%20Efendi.pdf
http://journalarticle.ukm.my/11365/
http://www.ukm.my/jsm/english_journals/vol46num9_2017/contentsVol46num9_2017.html
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Kebangsaan Malaysia
Language: English
id my-ukm.journal.11365
record_format eprints
spelling my-ukm.journal.113652018-02-12T03:03:23Z http://journalarticle.ukm.my/11365/ Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital M. Arif Efendi, Amporn Funsian, Thawat Chittrakarn, Tripob Bhongsuwan, In this study, 6 MV photon beam of TrueBeam STx Varian LINAC with Flattening Filter Free (FFF) was simulated using PRIMO code. The depth dose profiles for various jaws open fields and cross beam profiles for various depths inside water phantom were determined using Monte Carlo (MC) simulation technique and validated with experimental result. The experiments were performed using the Source to Surface Distance (SSD) technique with a 100 cm distance from target to the surface of water. Simulation used 109 histories with the same configurations with experiments. The depth dose profiles and cross beam profiles of 6 MV FFF photon beam was determined using MC simulations and compared with experimental results. The results showed that depth dose profiles and cross beam profiles by MC simulation accurately matched with experimental results. The best result of depth dose profile was obtained at 10×10 cm2 jaws open field with 98.53% passing criterion whereas cross beam profile was obtained at 10 cm depth inside water phantom with 88.96% passing criterion.The discrepancies were caused by scatter of particle and incompatibility of primary beam in PRIMO with experiment. Penerbit Universiti Kebangsaan Malaysia 2017-09 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/11365/1/08%20M.%20Arif%20Efendi.pdf M. Arif Efendi, and Amporn Funsian, and Thawat Chittrakarn, and Tripob Bhongsuwan, (2017) Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital. Sains Malaysiana, 46 (9). pp. 1407-1411. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol46num9_2017/contentsVol46num9_2017.html
institution Universiti Kebangsaan Malaysia
building Perpustakaan Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description In this study, 6 MV photon beam of TrueBeam STx Varian LINAC with Flattening Filter Free (FFF) was simulated using PRIMO code. The depth dose profiles for various jaws open fields and cross beam profiles for various depths inside water phantom were determined using Monte Carlo (MC) simulation technique and validated with experimental result. The experiments were performed using the Source to Surface Distance (SSD) technique with a 100 cm distance from target to the surface of water. Simulation used 109 histories with the same configurations with experiments. The depth dose profiles and cross beam profiles of 6 MV FFF photon beam was determined using MC simulations and compared with experimental results. The results showed that depth dose profiles and cross beam profiles by MC simulation accurately matched with experimental results. The best result of depth dose profile was obtained at 10×10 cm2 jaws open field with 98.53% passing criterion whereas cross beam profile was obtained at 10 cm depth inside water phantom with 88.96% passing criterion.The discrepancies were caused by scatter of particle and incompatibility of primary beam in PRIMO with experiment.
format Article
author M. Arif Efendi,
Amporn Funsian,
Thawat Chittrakarn,
Tripob Bhongsuwan,
spellingShingle M. Arif Efendi,
Amporn Funsian,
Thawat Chittrakarn,
Tripob Bhongsuwan,
Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
author_facet M. Arif Efendi,
Amporn Funsian,
Thawat Chittrakarn,
Tripob Bhongsuwan,
author_sort M. Arif Efendi,
title Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
title_short Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
title_full Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
title_fullStr Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
title_full_unstemmed Monte Carlo simulation of 6 MV flattening filter free photon beam of TrueBeam STx LINAC at Songklanagarind Hospital
title_sort monte carlo simulation of 6 mv flattening filter free photon beam of truebeam stx linac at songklanagarind hospital
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2017
url http://journalarticle.ukm.my/11365/1/08%20M.%20Arif%20Efendi.pdf
http://journalarticle.ukm.my/11365/
http://www.ukm.my/jsm/english_journals/vol46num9_2017/contentsVol46num9_2017.html
_version_ 1643738467813818368