The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions
Non-destructive test which refers to electrical resistivity method is recently popular in engineering, environmental, archaeological and mining studies. Based on the previous studies, the results on electrical resistivity interpretation were often debated due to lack of clarification and evidences i...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2017
|
Online Access: | http://journalarticle.ukm.my/11556/1/35%20Mohd%20Hazreek%20Zainal.pdf http://journalarticle.ukm.my/11556/ http://www.ukm.my/jsm/english_journals/vol46num10_2017/contentsVol46num10_2017.html |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Kebangsaan Malaysia |
Language: | English |
id |
my-ukm.journal.11556 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.115562018-04-10T10:11:53Z http://journalarticle.ukm.my/11556/ The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions Mohd Hazreek Zainal Abidin, Rosli Saad, Devapriya Chitral Wijeyesekera, Fauziah Ahmad, Mohamad Faizal Tajul Baharuddin, Saiful Azhar Ahmad Tajudin, Aziman Madun, Non-destructive test which refers to electrical resistivity method is recently popular in engineering, environmental, archaeological and mining studies. Based on the previous studies, the results on electrical resistivity interpretation were often debated due to lack of clarification and evidences in quantitative perspective. Traditionally, most of the previous result interpretations were depending on qualitative point of view which is risky to produce unreliable outcomes. In order to minimise those problems, this study has performed a laboratory experiment on soil box electrical resistivity test which was supported by an additional basic physical properties of soil test like particle size distribution test (d), moisture content test (w), density test (ρbulk) and Atterberg limit test (LL, PL and PI). The test was performed to establish a series of electrical resistivity value (ERV) with different quantity of water content for clayey silt and silty sand in loose and dense condition. Apparently, the soil resistivity value was different under loose (L) and dense (C) conditions with moisture content and density variations (silty SAND = ERVLoose: 600 - 7300 Ωm & ERVDense: 490 - 7900 Ωm while Clayey SILT = ERVLoose: 13 - 7700 Ωm & ERVDense: 14 - 8400 Ωm) due to several factors. Moreover, correlation of moisture content (w) and density (ρbulk) due to the ERV was established as follows; Silty SAND: w(L) = 638.8ρ-0.418, w(D) = 1397.1ρ-0.574, ρBulk(L) = 2.6188e-6E-05ρ, ρBulk(D) = 4.099ρ-0.07 while Clayey SILT: w(L) = 109.98ρ-0.268, w(D) = 121.88ρ-0.363, ρBulk(L) = -0.111ln(ρ) + 1.7605, ρBulk(D) = 2.5991ρ-0.037 with determination coefficients, R2 that varied from 0.5643 – 0.8927. This study was successfully demonstrated that the consistency of ERV was greatly influenced by the variation of soil basic physical properties (d, w, ρBulk, LL, PL and PI). Finally, the reliability of the ERV result interpretation can be enhanced due to its ability to produce a meaningful outcome based on supported data from basic geotechnical properties. Penerbit Universiti Kebangsaan Malaysia 2017-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/11556/1/35%20Mohd%20Hazreek%20Zainal.pdf Mohd Hazreek Zainal Abidin, and Rosli Saad, and Devapriya Chitral Wijeyesekera, and Fauziah Ahmad, and Mohamad Faizal Tajul Baharuddin, and Saiful Azhar Ahmad Tajudin, and Aziman Madun, (2017) The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions. Sains Malaysiana, 46 (10). pp. 1959-1969. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol46num10_2017/contentsVol46num10_2017.html |
institution |
Universiti Kebangsaan Malaysia |
building |
Perpustakaan Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
Non-destructive test which refers to electrical resistivity method is recently popular in engineering, environmental, archaeological and mining studies. Based on the previous studies, the results on electrical resistivity interpretation were often debated due to lack of clarification and evidences in quantitative perspective. Traditionally, most of the previous result interpretations were depending on qualitative point of view which is risky to produce unreliable outcomes. In order to minimise those problems, this study has performed a laboratory experiment on soil box electrical resistivity test which was supported by an additional basic physical properties of soil test like particle size distribution test (d), moisture content test (w), density test (ρbulk) and Atterberg limit test (LL, PL and PI). The test was performed to establish a series of electrical resistivity value (ERV) with different quantity of water content for clayey silt and silty sand in loose and dense condition. Apparently, the soil resistivity value was different under loose (L) and dense (C) conditions with moisture content and density variations (silty SAND = ERVLoose: 600 - 7300 Ωm & ERVDense: 490 - 7900 Ωm while Clayey SILT = ERVLoose: 13 - 7700 Ωm & ERVDense: 14 - 8400 Ωm) due to several factors. Moreover, correlation of moisture content (w) and density (ρbulk) due to the ERV was established as follows; Silty SAND: w(L) = 638.8ρ-0.418, w(D) = 1397.1ρ-0.574, ρBulk(L) = 2.6188e-6E-05ρ, ρBulk(D) = 4.099ρ-0.07 while Clayey SILT: w(L) = 109.98ρ-0.268, w(D) = 121.88ρ-0.363, ρBulk(L) = -0.111ln(ρ) + 1.7605, ρBulk(D) = 2.5991ρ-0.037 with determination coefficients, R2 that varied from 0.5643 – 0.8927. This study was successfully demonstrated that the consistency of ERV was greatly influenced by the variation of soil basic physical properties (d, w, ρBulk, LL, PL and PI). Finally, the reliability of the ERV result interpretation can be enhanced due to its ability to produce a meaningful outcome based on supported data from basic geotechnical properties. |
format |
Article |
author |
Mohd Hazreek Zainal Abidin, Rosli Saad, Devapriya Chitral Wijeyesekera, Fauziah Ahmad, Mohamad Faizal Tajul Baharuddin, Saiful Azhar Ahmad Tajudin, Aziman Madun, |
spellingShingle |
Mohd Hazreek Zainal Abidin, Rosli Saad, Devapriya Chitral Wijeyesekera, Fauziah Ahmad, Mohamad Faizal Tajul Baharuddin, Saiful Azhar Ahmad Tajudin, Aziman Madun, The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
author_facet |
Mohd Hazreek Zainal Abidin, Rosli Saad, Devapriya Chitral Wijeyesekera, Fauziah Ahmad, Mohamad Faizal Tajul Baharuddin, Saiful Azhar Ahmad Tajudin, Aziman Madun, |
author_sort |
Mohd Hazreek Zainal Abidin, |
title |
The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
title_short |
The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
title_full |
The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
title_fullStr |
The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
title_full_unstemmed |
The influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
title_sort |
influences of basic physical properties of clayey silt and silty sand on its laboratory electrical resistivity value in loose and dense conditions |
publisher |
Penerbit Universiti Kebangsaan Malaysia |
publishDate |
2017 |
url |
http://journalarticle.ukm.my/11556/1/35%20Mohd%20Hazreek%20Zainal.pdf http://journalarticle.ukm.my/11556/ http://www.ukm.my/jsm/english_journals/vol46num10_2017/contentsVol46num10_2017.html |
_version_ |
1643738535112474624 |