Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique
It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2019
|
Online Access: | http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf http://journalarticle.ukm.my/14397/ http://www.ukm.my/jsm/malay_journals/jilid48bil10_2019/KandunganJilid48Bil10_2019.htm |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Kebangsaan Malaysia |
Language: | English |
id |
my-ukm.journal.14397 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.143972020-03-10T02:31:44Z http://journalarticle.ukm.my/14397/ Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto, It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed by any studies. This study presented and analysed the validity of a newly-developed automated infrared-based treadmill walking monitoring system (iTMS), which as specifically designed to measure the distance and characteristics for the walk performance of a non-motorised treadmill 6MWT (nMT6MWT). This study selected 20 subjects for: The validity testing of the iTMS walked distance at five different speeds dictated by metronome beats for 2-minute and at a self-paced speed with intermittent rests for 6-minute, and the characterisation of 6-minute walk performance for distance, speed, acceleration, walking segments, and resting events. The iTMS measured distances were consistently accurate for the varying speeds during the 2-minute walk session. For the 6-minute walk en bloc and its three segments, the difference in distance (Δd) between iTMS (diTMS) and camera recording method (dCRM) showed positive biases with small LOA95% in Bland-Altman plot. The iTMS has an accurate distance measurement with ± 0.20% error of dCRM for en bloc 6-minute walk can characterise the resting events of 0.5 s and more. The iTMS is considered a viable automated method for monitoring distance and characterising nMT6MWT. It also showed the potential in addressing technical errors which may be inherent in manual 6MWT data collection methods. Penerbit Universiti Kebangsaan Malaysia 2019-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf Isniza Ismail, and Leela T. Narayanan, and Rumaisa Abu Hasan, and Eko Supriyanto, (2019) Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique. Sains Malaysiana, 48 (10). pp. 2201-2209. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid48bil10_2019/KandunganJilid48Bil10_2019.htm |
institution |
Universiti Kebangsaan Malaysia |
building |
Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
It is common to use motorised and non-motorised treadmills in settings with space constraints for a 6-minute walk test (6MWT). This test used manual methods which are susceptible to errors. It is believed that automated techniques could eliminate the shortcomings, but this approach was not proposed by any studies. This study presented and analysed the validity of a newly-developed automated infrared-based treadmill walking monitoring system (iTMS), which as specifically designed to measure the distance and characteristics for the walk performance of a non-motorised treadmill 6MWT (nMT6MWT). This study selected 20 subjects for: The validity testing of the iTMS walked distance at five different speeds dictated by metronome beats for 2-minute and at a self-paced speed with intermittent rests for 6-minute, and the characterisation of 6-minute walk performance for distance, speed, acceleration, walking segments, and resting events. The iTMS measured distances were consistently accurate for the varying speeds during the 2-minute walk session. For the 6-minute walk en bloc and its three segments, the difference in distance (Δd) between iTMS (diTMS) and camera recording method (dCRM) showed positive biases with small LOA95% in Bland-Altman plot. The iTMS has an accurate distance measurement with ± 0.20% error of dCRM for en bloc 6-minute walk can characterise the resting events of 0.5 s and more. The iTMS is considered a viable automated method for monitoring distance and characterising nMT6MWT. It also showed the potential in addressing technical errors which may be inherent in manual 6MWT data collection methods. |
format |
Article |
author |
Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto, |
spellingShingle |
Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto, Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
author_facet |
Isniza Ismail, Leela T. Narayanan, Rumaisa Abu Hasan, Eko Supriyanto, |
author_sort |
Isniza Ismail, |
title |
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
title_short |
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
title_full |
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
title_fullStr |
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
title_full_unstemmed |
Automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
title_sort |
automated 6-minute walk test distance measurement and walk characterisation using a novel infrared sensor-based technique |
publisher |
Penerbit Universiti Kebangsaan Malaysia |
publishDate |
2019 |
url |
http://journalarticle.ukm.my/14397/1/16%20Isniza%20Ismail.pdf http://journalarticle.ukm.my/14397/ http://www.ukm.my/jsm/malay_journals/jilid48bil10_2019/KandunganJilid48Bil10_2019.htm |
_version_ |
1662755962270777344 |