The application of multi-phase power distribution line with pure energy conversion

This paper discusses the power transmission of a six-phase power line with a six-phase LPWM inverter. The 20 km long line with six-phase is formed to be fed from the 6-phase multi-level inverter. The structure of the line and the elements of the power line are given in the design phase. After that,...

Full description

Saved in:
Bibliographic Details
Main Author: Can, Erol
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2019
Online Access:http://journalarticle.ukm.my/14811/1/02.pdf
http://journalarticle.ukm.my/14811/
http://www.ukm.my/jkukm/volume-312-2019/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Kebangsaan Malaysia
Language: English
id my-ukm.journal.14811
record_format eprints
spelling my-ukm.journal.148112020-07-10T01:47:28Z http://journalarticle.ukm.my/14811/ The application of multi-phase power distribution line with pure energy conversion Can, Erol This paper discusses the power transmission of a six-phase power line with a six-phase LPWM inverter. The 20 km long line with six-phase is formed to be fed from the 6-phase multi-level inverter. The structure of the line and the elements of the power line are given in the design phase. After that, mathematical analysis of the power line is done to present information on the line structure and the relationship between the variables of the line. In the application stage, the described line is operating in Matlab Simulink. The input voltage of the line, the voltage of the RC parallel filter on the line and the voltage of the 1MW load on the line are measured. Six phase flux of the power is measured according to b2 and b4 bus points. Harmonic distortion of created voltages is measured. The harmonic distortion of the voltage on the Z2 impedance is 0.12%. This level of deterioration is well below the international standard of 5% and is an ideal result for loads that need a pure multi-phase magnetic field. 6-phase voltage is measured at 244V amplitude on a 6-phase load with 1 MVA power connecting the secondary side of the transformer. Then, the distortion of this voltage is close to zero. This result is highly desirable for a load on the power line. Based on the results obtained, the power is transmitted over a 20 km long line with high quality successfully. Penerbit Universiti Kebangsaan Malaysia 2019-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/14811/1/02.pdf Can, Erol (2019) The application of multi-phase power distribution line with pure energy conversion. Jurnal Kejuruteraan, 31 (2). pp. 193-199. ISSN 0128-0198 http://www.ukm.my/jkukm/volume-312-2019/
institution Universiti Kebangsaan Malaysia
building Tun Sri Lanang Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Kebangsaan Malaysia
content_source UKM Journal Article Repository
url_provider http://journalarticle.ukm.my/
language English
description This paper discusses the power transmission of a six-phase power line with a six-phase LPWM inverter. The 20 km long line with six-phase is formed to be fed from the 6-phase multi-level inverter. The structure of the line and the elements of the power line are given in the design phase. After that, mathematical analysis of the power line is done to present information on the line structure and the relationship between the variables of the line. In the application stage, the described line is operating in Matlab Simulink. The input voltage of the line, the voltage of the RC parallel filter on the line and the voltage of the 1MW load on the line are measured. Six phase flux of the power is measured according to b2 and b4 bus points. Harmonic distortion of created voltages is measured. The harmonic distortion of the voltage on the Z2 impedance is 0.12%. This level of deterioration is well below the international standard of 5% and is an ideal result for loads that need a pure multi-phase magnetic field. 6-phase voltage is measured at 244V amplitude on a 6-phase load with 1 MVA power connecting the secondary side of the transformer. Then, the distortion of this voltage is close to zero. This result is highly desirable for a load on the power line. Based on the results obtained, the power is transmitted over a 20 km long line with high quality successfully.
format Article
author Can, Erol
spellingShingle Can, Erol
The application of multi-phase power distribution line with pure energy conversion
author_facet Can, Erol
author_sort Can, Erol
title The application of multi-phase power distribution line with pure energy conversion
title_short The application of multi-phase power distribution line with pure energy conversion
title_full The application of multi-phase power distribution line with pure energy conversion
title_fullStr The application of multi-phase power distribution line with pure energy conversion
title_full_unstemmed The application of multi-phase power distribution line with pure energy conversion
title_sort application of multi-phase power distribution line with pure energy conversion
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2019
url http://journalarticle.ukm.my/14811/1/02.pdf
http://journalarticle.ukm.my/14811/
http://www.ukm.my/jkukm/volume-312-2019/
_version_ 1672611740084338688