Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane
This was a prospective randomised study comparing carboxyhaemoglobin concentrations between low-flow anaesthesia (fresh gas flow 1.0 L/min) and minimal-flow anaesthesia (0.5 L/min) using desflurane. Sixty (ASA 1 or 2) adult patients undergoing elective surgery under general anaesthesia were randomly...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Department of Surgery, UKM Medical Centre
2015
|
Online Access: | http://journalarticle.ukm.my/8651/1/04-Nazarudin%2520B%2520et%2520al..pdf http://journalarticle.ukm.my/8651/ http://jsurgical.com |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Kebangsaan Malaysia |
Language: | English |
id |
my-ukm.journal.8651 |
---|---|
record_format |
eprints |
spelling |
my-ukm.journal.86512016-12-14T06:47:47Z http://journalarticle.ukm.my/8651/ Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane Nazarudin B., Khairulamir Z., Azarinah I., Jaafar MZ., Karis M., Esa K., This was a prospective randomised study comparing carboxyhaemoglobin concentrations between low-flow anaesthesia (fresh gas flow 1.0 L/min) and minimal-flow anaesthesia (0.5 L/min) using desflurane. Sixty (ASA 1 or 2) adult patients undergoing elective surgery under general anaesthesia were randomly allocated to receive either low-flow (Group 1) or minimal flow anaesthesia (Group 2). Venous blood samples for carboxyhaemoglobin levels were taken at baseline and at 10 mins intervals for 40 mins. Both groups showed significant increase in carboxyhaemoglobin concentrations within the first 10 mins when fresh gas flow of 4.0 L/min was used. Reduction in carboxyhemoglobin levels was seen after 20 mins of minimal or low flow anaesthesia. However, there was no significant difference in the magnitude of reduction of carboxyhemoglobin concentrations between the groups. The fractional inspired of oxygen (FiO2) showed no significant changes in either group. In conclusion, desflurane usage in anaesthesia with either low-flow or minimal-flow was not associated with increased carboxyhaemoglobin concentrations. Department of Surgery, UKM Medical Centre 2015-06-04 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/8651/1/04-Nazarudin%2520B%2520et%2520al..pdf Nazarudin B., and Khairulamir Z., and Azarinah I., and Jaafar MZ., and Karis M., and Esa K., (2015) Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane. Journal of Surgical Academia, vol.5 (1). pp. 19-23. ISSN 2231-7481 http://jsurgical.com |
institution |
Universiti Kebangsaan Malaysia |
building |
Perpustakaan Tun Sri Lanang Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Kebangsaan Malaysia |
content_source |
UKM Journal Article Repository |
url_provider |
http://journalarticle.ukm.my/ |
language |
English |
description |
This was a prospective randomised study comparing carboxyhaemoglobin concentrations between low-flow anaesthesia (fresh gas flow 1.0 L/min) and minimal-flow anaesthesia (0.5 L/min) using desflurane. Sixty (ASA 1 or 2) adult patients undergoing elective surgery under general anaesthesia were randomly allocated to receive either low-flow (Group 1) or minimal flow anaesthesia (Group 2). Venous blood samples for carboxyhaemoglobin levels were taken at baseline and at 10 mins intervals for 40 mins. Both groups showed significant increase in carboxyhaemoglobin concentrations within the first 10 mins when fresh gas flow of 4.0 L/min was used. Reduction in carboxyhemoglobin levels was seen after 20 mins of minimal or low flow anaesthesia. However, there was no significant difference in the magnitude of reduction of carboxyhemoglobin concentrations between the groups. The fractional inspired of oxygen (FiO2) showed no significant changes in either group. In conclusion, desflurane usage in anaesthesia with either low-flow or minimal-flow was not associated with increased carboxyhaemoglobin concentrations. |
format |
Article |
author |
Nazarudin B., Khairulamir Z., Azarinah I., Jaafar MZ., Karis M., Esa K., |
spellingShingle |
Nazarudin B., Khairulamir Z., Azarinah I., Jaafar MZ., Karis M., Esa K., Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
author_facet |
Nazarudin B., Khairulamir Z., Azarinah I., Jaafar MZ., Karis M., Esa K., |
author_sort |
Nazarudin B., |
title |
Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
title_short |
Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
title_full |
Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
title_fullStr |
Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
title_full_unstemmed |
Comparison of Carboxyhaemoglobin Concentrations between Low-flow and Minimal-flow Anaesthesia with Desflurane |
title_sort |
comparison of carboxyhaemoglobin concentrations between low-flow and minimal-flow anaesthesia with desflurane |
publisher |
Department of Surgery, UKM Medical Centre |
publishDate |
2015 |
url |
http://journalarticle.ukm.my/8651/1/04-Nazarudin%2520B%2520et%2520al..pdf http://journalarticle.ukm.my/8651/ http://jsurgical.com |
_version_ |
1643737539306061824 |