Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park

In recent years, the ductless impulse jet fans ventilation system has been increasingly preferred over the traditional ducted ventilation system for car park ventilation applications. Aside from ventilation, the jet fans system offers several additional advantages such as low design complexity, cost...

Full description

Saved in:
Bibliographic Details
Main Author: Tneh, Xuan
Format: Final Year Project / Dissertation / Thesis
Published: 2023
Subjects:
Online Access:http://eprints.utar.edu.my/5405/1/TNEH_XUAN_2202577.pdf
http://eprints.utar.edu.my/5405/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tunku Abdul Rahman
id my-utar-eprints.5405
record_format eprints
spelling my-utar-eprints.54052023-06-20T14:12:09Z Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park Tneh, Xuan TJ Mechanical engineering and machinery In recent years, the ductless impulse jet fans ventilation system has been increasingly preferred over the traditional ducted ventilation system for car park ventilation applications. Aside from ventilation, the jet fans system offers several additional advantages such as low design complexity, cost-saving, space-saving, and low maintenance which make it to supersede the ducted system. Despite all the advantages, ventilation performance remains the primary concern for every car park ventilation system. The complex geometry of car parks can contribute to a highly unpredictable airflow behaviour when jet fans are used. Therefore, an experimental approach like CFD modelling is required for an accurate evaluation of the ventilation performance. In this project, an impulse jet fans system was designed in strict accordance with the authorities’ requirements for the existing block KB basement car park at UTAR Sungai Long campus. A detailed CFD modelling was carried out to compare the ventilation performance between the existing ducted ventilation system and the jet fans system in the enclosed car park during a fire. The results have shown that the ducted ventilation system can provide a better ventilation during a fire. Although the jet fans system is not as efficient as the ducted model, it managed to fulfil most of the ventilation criteria required by the local authorities. 2023 Final Year Project / Dissertation / Thesis NonPeerReviewed application/pdf http://eprints.utar.edu.my/5405/1/TNEH_XUAN_2202577.pdf Tneh, Xuan (2023) Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park. Master dissertation/thesis, UTAR. http://eprints.utar.edu.my/5405/
institution Universiti Tunku Abdul Rahman
building UTAR Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tunku Abdul Rahman
content_source UTAR Institutional Repository
url_provider http://eprints.utar.edu.my
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Tneh, Xuan
Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
description In recent years, the ductless impulse jet fans ventilation system has been increasingly preferred over the traditional ducted ventilation system for car park ventilation applications. Aside from ventilation, the jet fans system offers several additional advantages such as low design complexity, cost-saving, space-saving, and low maintenance which make it to supersede the ducted system. Despite all the advantages, ventilation performance remains the primary concern for every car park ventilation system. The complex geometry of car parks can contribute to a highly unpredictable airflow behaviour when jet fans are used. Therefore, an experimental approach like CFD modelling is required for an accurate evaluation of the ventilation performance. In this project, an impulse jet fans system was designed in strict accordance with the authorities’ requirements for the existing block KB basement car park at UTAR Sungai Long campus. A detailed CFD modelling was carried out to compare the ventilation performance between the existing ducted ventilation system and the jet fans system in the enclosed car park during a fire. The results have shown that the ducted ventilation system can provide a better ventilation during a fire. Although the jet fans system is not as efficient as the ducted model, it managed to fulfil most of the ventilation criteria required by the local authorities.
format Final Year Project / Dissertation / Thesis
author Tneh, Xuan
author_facet Tneh, Xuan
author_sort Tneh, Xuan
title Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
title_short Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
title_full Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
title_fullStr Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
title_full_unstemmed Numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
title_sort numerical analysis of the ducted ventilation and jet fans systems in an enclosed car park
publishDate 2023
url http://eprints.utar.edu.my/5405/1/TNEH_XUAN_2202577.pdf
http://eprints.utar.edu.my/5405/
_version_ 1770556048738877440