Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe

Due to relatively low cost and combination of ductility and strength, metal is preferred material for pipeline in oil and gas industry. However, metal can easily get corroded which is the major problem faced by the industry. To tackle the issue, non-metallic composite pipe was proposed. Since the...

Full description

Saved in:
Bibliographic Details
Main Author: GERARD , SUE WEI PING
Format: Final Year Project
Language:English
Published: IRC 2015
Subjects:
Online Access:http://utpedia.utp.edu.my/16223/1/monotonic%20burst%20%28disertation%29.pdf
http://utpedia.utp.edu.my/16223/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
Language: English
id my-utp-utpedia.16223
record_format eprints
spelling my-utp-utpedia.162232017-01-25T09:35:26Z http://utpedia.utp.edu.my/16223/ Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe GERARD , SUE WEI PING TJ Mechanical engineering and machinery Due to relatively low cost and combination of ductility and strength, metal is preferred material for pipeline in oil and gas industry. However, metal can easily get corroded which is the major problem faced by the industry. To tackle the issue, non-metallic composite pipe was proposed. Since the non-metallic composite is relatively new, studies on the monotonic burst pressure is quite rare. Efforts were made to study the monotonic burst pressure last semester but failed due to the leaking problem. The objectives of this project are to design end caps without any leakage problem and to evaluate the monotonic burst pressure of the composite pipe. In this project, high density polyethylene (HDPE) was used as the liner, epoxy was applied as matrix and glass fiber was employed as the reinforcement. Filament winding was used to fabricate the composite pipe. In the process of fabrication, the composition used was 50:50 (epoxy/ glass fiber). The pipe underwent preliminary leak test using the manual hydrostatic pump at UTP and monotonic burst test at Sirim Venture Tech (SVT). Sdn. Bhd, Penang. The preliminary leak test was done successfully without any leakage at 30 bar. The average monotonic burst pressure was 102.5 bar which is higher than the design pressure for similar pipe made from carbon steel [2]. IRC 2015-05 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/16223/1/monotonic%20burst%20%28disertation%29.pdf GERARD , SUE WEI PING (2015) Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe. IRC, Universiti Teknologi PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
GERARD , SUE WEI PING
Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
description Due to relatively low cost and combination of ductility and strength, metal is preferred material for pipeline in oil and gas industry. However, metal can easily get corroded which is the major problem faced by the industry. To tackle the issue, non-metallic composite pipe was proposed. Since the non-metallic composite is relatively new, studies on the monotonic burst pressure is quite rare. Efforts were made to study the monotonic burst pressure last semester but failed due to the leaking problem. The objectives of this project are to design end caps without any leakage problem and to evaluate the monotonic burst pressure of the composite pipe. In this project, high density polyethylene (HDPE) was used as the liner, epoxy was applied as matrix and glass fiber was employed as the reinforcement. Filament winding was used to fabricate the composite pipe. In the process of fabrication, the composition used was 50:50 (epoxy/ glass fiber). The pipe underwent preliminary leak test using the manual hydrostatic pump at UTP and monotonic burst test at Sirim Venture Tech (SVT). Sdn. Bhd, Penang. The preliminary leak test was done successfully without any leakage at 30 bar. The average monotonic burst pressure was 102.5 bar which is higher than the design pressure for similar pipe made from carbon steel [2].
format Final Year Project
author GERARD , SUE WEI PING
author_facet GERARD , SUE WEI PING
author_sort GERARD , SUE WEI PING
title Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
title_short Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
title_full Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
title_fullStr Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
title_full_unstemmed Monotonic Burst Pressure of Non-Metallic Filament Wound Composite Pipe
title_sort monotonic burst pressure of non-metallic filament wound composite pipe
publisher IRC
publishDate 2015
url http://utpedia.utp.edu.my/16223/1/monotonic%20burst%20%28disertation%29.pdf
http://utpedia.utp.edu.my/16223/
_version_ 1739832232619540480