The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping

In the effort of sustaining the reliability of equipments, periodic maintenance and inspection is required. This is done by applying the non-destructive testing (NDT) techniques like ultrasonic, radiography, and etc. NDT act as the appropriate tool for engineers and inspectors to examine the presenc...

Full description

Saved in:
Bibliographic Details
Main Author: Muhamad Firdaus Bin Zaini, Muhamad Firdaus
Format: Final Year Project
Language:English
Published: Universiti Teknologi Petronas 2012
Subjects:
Online Access:http://utpedia.utp.edu.my/5636/1/FYP%20Dissertation_Muhamad%20Firdaus%20bin%20Zaini_%28PE_12045%29.pdf
http://utpedia.utp.edu.my/5636/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
Language: English
id my-utp-utpedia.5636
record_format eprints
spelling my-utp-utpedia.56362017-01-25T09:40:08Z http://utpedia.utp.edu.my/5636/ The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping Muhamad Firdaus Bin Zaini, Muhamad Firdaus TN Mining engineering. Metallurgy In the effort of sustaining the reliability of equipments, periodic maintenance and inspection is required. This is done by applying the non-destructive testing (NDT) techniques like ultrasonic, radiography, and etc. NDT act as the appropriate tool for engineers and inspectors to examine the presence and absence of any failures or defects on certain equipments without producing any disturbance to the equipments‟ process and operation [1]. In oil and gas industry, corrosion under insulation (CUI) is considered as the major problem arise today as it requires billion costs to inspect the corrosion involving the procedure to unwrap the insulation which will lead to 3 - 4 days operation. With the conventional NDT practice, this matter has been identified as time-consuming and costly operation. Therefore, the aim of this study was to validate the use of infrared thermography as NDT and E in locating and detecting CUI through lockin thermography testing. For this experimental study, a laboratory cell was designed to simulate the condition of CUI using the carbon steel plate (testing object) as a mock-up downstream pipe section. Factors include insulation thickness, defect‟s size, defect‟s depth, and the objective distance are the parameters affecting the accuracy of the results. For this purpose, infrared image correlation and numerical computation was used to predict the presence tendency of CUI. By numerical computation, it was demonstrated in this study that defect exhibit different temperature distribution as time elapsed. In contrast, temperature drops as the insulation becomes thick. By correlation, classification on thermal infrared colors governs the area of both defects and non-defects distinctively. It is obvious that the applicability of the present NDT and E to detect CUI depends on a heating condition and a relative difference of thermophysical property between the defect and its surrounding. Universiti Teknologi Petronas 2012-09 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/5636/1/FYP%20Dissertation_Muhamad%20Firdaus%20bin%20Zaini_%28PE_12045%29.pdf Muhamad Firdaus Bin Zaini, Muhamad Firdaus (2012) The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping. Universiti Teknologi Petronas. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TN Mining engineering. Metallurgy
spellingShingle TN Mining engineering. Metallurgy
Muhamad Firdaus Bin Zaini, Muhamad Firdaus
The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
description In the effort of sustaining the reliability of equipments, periodic maintenance and inspection is required. This is done by applying the non-destructive testing (NDT) techniques like ultrasonic, radiography, and etc. NDT act as the appropriate tool for engineers and inspectors to examine the presence and absence of any failures or defects on certain equipments without producing any disturbance to the equipments‟ process and operation [1]. In oil and gas industry, corrosion under insulation (CUI) is considered as the major problem arise today as it requires billion costs to inspect the corrosion involving the procedure to unwrap the insulation which will lead to 3 - 4 days operation. With the conventional NDT practice, this matter has been identified as time-consuming and costly operation. Therefore, the aim of this study was to validate the use of infrared thermography as NDT and E in locating and detecting CUI through lockin thermography testing. For this experimental study, a laboratory cell was designed to simulate the condition of CUI using the carbon steel plate (testing object) as a mock-up downstream pipe section. Factors include insulation thickness, defect‟s size, defect‟s depth, and the objective distance are the parameters affecting the accuracy of the results. For this purpose, infrared image correlation and numerical computation was used to predict the presence tendency of CUI. By numerical computation, it was demonstrated in this study that defect exhibit different temperature distribution as time elapsed. In contrast, temperature drops as the insulation becomes thick. By correlation, classification on thermal infrared colors governs the area of both defects and non-defects distinctively. It is obvious that the applicability of the present NDT and E to detect CUI depends on a heating condition and a relative difference of thermophysical property between the defect and its surrounding.
format Final Year Project
author Muhamad Firdaus Bin Zaini, Muhamad Firdaus
author_facet Muhamad Firdaus Bin Zaini, Muhamad Firdaus
author_sort Muhamad Firdaus Bin Zaini, Muhamad Firdaus
title The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
title_short The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
title_full The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
title_fullStr The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
title_full_unstemmed The Enhancement of NDT Techniques through Active Thermal Infrared Thermography to Identify Corrosion under Insulation (CUI) in Downstream Piping
title_sort enhancement of ndt techniques through active thermal infrared thermography to identify corrosion under insulation (cui) in downstream piping
publisher Universiti Teknologi Petronas
publishDate 2012
url http://utpedia.utp.edu.my/5636/1/FYP%20Dissertation_Muhamad%20Firdaus%20bin%20Zaini_%28PE_12045%29.pdf
http://utpedia.utp.edu.my/5636/
_version_ 1739831249015406592