Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique

Control valve, commonly known as final control element, is the vital element of any process plant and its performance must be monitored regularly to detect any problem occurring in advance. The detection of defects in control valve at early stages is crucial for plant operator to prevent unexpected...

Full description

Saved in:
Bibliographic Details
Main Author: DO , THAI HA
Format: Final Year Project
Language:English
Published: UNIVERSITI TEKNOLOGI PETRONAS 2013
Subjects:
Online Access:http://utpedia.utp.edu.my/6362/1/12964_Final_Dissertation.pdf
http://utpedia.utp.edu.my/6362/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
Language: English
id my-utp-utpedia.6362
record_format eprints
spelling my-utp-utpedia.63622017-01-25T09:39:23Z http://utpedia.utp.edu.my/6362/ Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique DO , THAI HA TK Electrical engineering. Electronics Nuclear engineering Control valve, commonly known as final control element, is the vital element of any process plant and its performance must be monitored regularly to detect any problem occurring in advance. The detection of defects in control valve at early stages is crucial for plant operator to prevent unexpected shutdown. Thus, an effective maintenance plan could be set up to minimize the costly downtime. This project concentrates on investigating the unhealthy control valves characteristics based on the Acoustic Emission (AE) signal emitted from the fault. From that, the description about the AE characteristic of unhealthy control valve is made and it can be applied for further application in online monitoring system. The project is divided into three stages. The first stage concentrates on preliminary research on the AE signal characteristics and its application on fault monitoring system. The second stage continues with the data saving process, where an experiment test rig is improved to serve the purpose of experiment activities and AE signal capturing. The experiment foundation basically includes a simple prototype of a process control loop accompany with a signal processing system where an AE sensor is implemented. At the end, the final stage of this project concentrates on processing the recorded AE signal by performing the signal analysis in frequency domain, using Fast Fourier Transform (FFT) and statistical analysis methods. Eventually, conclusions will be made up to summarize the AE signal characteristic of the unhealthy valve. UNIVERSITI TEKNOLOGI PETRONAS 2013-01 Final Year Project NonPeerReviewed application/pdf en http://utpedia.utp.edu.my/6362/1/12964_Final_Dissertation.pdf DO , THAI HA (2013) Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique. UNIVERSITI TEKNOLOGI PETRONAS, UNIVERSITI TEKNOLOGI PETRONAS. (Unpublished)
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Electronic and Digitized Intellectual Asset
url_provider http://utpedia.utp.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
DO , THAI HA
Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
description Control valve, commonly known as final control element, is the vital element of any process plant and its performance must be monitored regularly to detect any problem occurring in advance. The detection of defects in control valve at early stages is crucial for plant operator to prevent unexpected shutdown. Thus, an effective maintenance plan could be set up to minimize the costly downtime. This project concentrates on investigating the unhealthy control valves characteristics based on the Acoustic Emission (AE) signal emitted from the fault. From that, the description about the AE characteristic of unhealthy control valve is made and it can be applied for further application in online monitoring system. The project is divided into three stages. The first stage concentrates on preliminary research on the AE signal characteristics and its application on fault monitoring system. The second stage continues with the data saving process, where an experiment test rig is improved to serve the purpose of experiment activities and AE signal capturing. The experiment foundation basically includes a simple prototype of a process control loop accompany with a signal processing system where an AE sensor is implemented. At the end, the final stage of this project concentrates on processing the recorded AE signal by performing the signal analysis in frequency domain, using Fast Fourier Transform (FFT) and statistical analysis methods. Eventually, conclusions will be made up to summarize the AE signal characteristic of the unhealthy valve.
format Final Year Project
author DO , THAI HA
author_facet DO , THAI HA
author_sort DO , THAI HA
title Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
title_short Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
title_full Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
title_fullStr Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
title_full_unstemmed Investigation on Unhealthy Control Valve Characteristic using Acoustic Emission Technique
title_sort investigation on unhealthy control valve characteristic using acoustic emission technique
publisher UNIVERSITI TEKNOLOGI PETRONAS
publishDate 2013
url http://utpedia.utp.edu.my/6362/1/12964_Final_Dissertation.pdf
http://utpedia.utp.edu.my/6362/
_version_ 1739831340488982528