A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease

Background: Artificial tears (ATs) are widely used in ophthalmic practice with various formulations, mainly as a treatment for dry eye, owing to their rapid ability to alleviate the signs and symptoms of this condition. We aimed to investigate drop comfort and subjective ocular symptoms after instil...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Arif, Fatin Amalina, Hilmi, Mohd Radzi, Mohd. Kamal, Khairidzan
Format: Article
Language:English
Published: International Virtual Ophthalmic Research Center 2023
Subjects:
Online Access:http://irep.iium.edu.my/109007/7/109007_A%20prospective%20contralateral%20eye%20comparison%20of%20the%20tolerability.pdf
http://irep.iium.edu.my/109007/
https://mehdijournal.com/index.php/mehdioptometry/article/view/1083
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.109007
record_format dspace
spelling my.iium.irep.1090072023-12-20T07:45:27Z http://irep.iium.edu.my/109007/ A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease Che Arif, Fatin Amalina Hilmi, Mohd Radzi Mohd. Kamal, Khairidzan RE Ophthalmology Background: Artificial tears (ATs) are widely used in ophthalmic practice with various formulations, mainly as a treatment for dry eye, owing to their rapid ability to alleviate the signs and symptoms of this condition. We aimed to investigate drop comfort and subjective ocular symptoms after instillation of the following ATs with different physical properties: Optive® non-preservative (OUD) and Systane® Hydration non-preservative (SHUD). Methods: This was a prospective, double-blind, randomized, contralateral eye comparison study. A rheometer and a digital pH meter were used to evaluate the viscosity and pH of both ATs prior to instillation. We recruited 36 patients with dry eye disease. Single standardized AT volumes were set using a micropipette for all patients. Ocular discomfort was assessed using the Ora CalibraTM Ocular Discomfort and 4-Symptom Questionnaire (OOD4SQ; 0 – 5 scale) before and 60 min after instillation. Drop comfort was assessed using the Ora CalibraTM Drop Comfort Scale (0 – 10 scale) immediately after AT instillation. The difference in the drop comfort score (DCS) between the two ATs and ocular discomfort scores using OOD4SQ before and 60 min after instillation of each AT were recorded and compared. Results: The viscosities and pH of SHUD and OUD were 32.73 centipoise (cP) and 7.74 and 14.42 cP and 7.19, respectively. The mean (standard deviation) DCS was higher in the SHUD group than in the OUD group (1.83 [1.21] versus 1.67 [1.12]); however, the difference was not statistically significant (P > 0.05). There was a significant reduction in all parameters of OOD4SQ including overall discomfort, burning, dryness, grittiness, and stinging 60 min after OUD instillation (all P < 0.05), while a significant difference was only noted in dryness (P < 0.05) in the SHUD group. Conclusions: OUD, which has a lower viscosity and pH compared to SHUD, provides less subjective sensation and better ocular comfort 60 min after instillation. Further randomized clinical trials including patients with dry eye disease of different severities, larger sample sizes, and longer follow-up periods are required to verify our findings. International Virtual Ophthalmic Research Center 2023-04-04 Article PeerReviewed application/pdf en http://irep.iium.edu.my/109007/7/109007_A%20prospective%20contralateral%20eye%20comparison%20of%20the%20tolerability.pdf Che Arif, Fatin Amalina and Hilmi, Mohd Radzi and Mohd. Kamal, Khairidzan (2023) A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease. Medical Hypothesis, Discovery & Innovation In Optometry, 4 (1). pp. 1-6. ISSN 2693-8391 https://mehdijournal.com/index.php/mehdioptometry/article/view/1083 10.51329/mehdioptometry167
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
description Background: Artificial tears (ATs) are widely used in ophthalmic practice with various formulations, mainly as a treatment for dry eye, owing to their rapid ability to alleviate the signs and symptoms of this condition. We aimed to investigate drop comfort and subjective ocular symptoms after instillation of the following ATs with different physical properties: Optive® non-preservative (OUD) and Systane® Hydration non-preservative (SHUD). Methods: This was a prospective, double-blind, randomized, contralateral eye comparison study. A rheometer and a digital pH meter were used to evaluate the viscosity and pH of both ATs prior to instillation. We recruited 36 patients with dry eye disease. Single standardized AT volumes were set using a micropipette for all patients. Ocular discomfort was assessed using the Ora CalibraTM Ocular Discomfort and 4-Symptom Questionnaire (OOD4SQ; 0 – 5 scale) before and 60 min after instillation. Drop comfort was assessed using the Ora CalibraTM Drop Comfort Scale (0 – 10 scale) immediately after AT instillation. The difference in the drop comfort score (DCS) between the two ATs and ocular discomfort scores using OOD4SQ before and 60 min after instillation of each AT were recorded and compared. Results: The viscosities and pH of SHUD and OUD were 32.73 centipoise (cP) and 7.74 and 14.42 cP and 7.19, respectively. The mean (standard deviation) DCS was higher in the SHUD group than in the OUD group (1.83 [1.21] versus 1.67 [1.12]); however, the difference was not statistically significant (P > 0.05). There was a significant reduction in all parameters of OOD4SQ including overall discomfort, burning, dryness, grittiness, and stinging 60 min after OUD instillation (all P < 0.05), while a significant difference was only noted in dryness (P < 0.05) in the SHUD group. Conclusions: OUD, which has a lower viscosity and pH compared to SHUD, provides less subjective sensation and better ocular comfort 60 min after instillation. Further randomized clinical trials including patients with dry eye disease of different severities, larger sample sizes, and longer follow-up periods are required to verify our findings.
format Article
author Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
author_facet Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd. Kamal, Khairidzan
author_sort Che Arif, Fatin Amalina
title A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
title_short A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
title_full A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
title_fullStr A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
title_full_unstemmed A prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
title_sort prospective contralateral eye comparison of the tolerability of two artificial tears with different physical properties in patients with dry eye disease
publisher International Virtual Ophthalmic Research Center
publishDate 2023
url http://irep.iium.edu.my/109007/7/109007_A%20prospective%20contralateral%20eye%20comparison%20of%20the%20tolerability.pdf
http://irep.iium.edu.my/109007/
https://mehdijournal.com/index.php/mehdioptometry/article/view/1083
_version_ 1787131915689525248