Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics

Introduction: This study aimed to evaluate the short-term efficacy of two comparable formulation of dual-polymer artificial tears: Systane Hydration preservative (SH) and non-preservative (SHUD) in 60 minutes observation period compared to normal saline. Methods: Fifty participants involved in this...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Arif, Fatin Amalina, Hilmi, Mohd Radzi, Mohd Kamal, Khairidzan, Ithnin, Mohd. Hafidz
Format: Article
Language:English
English
Published: Universiti Putra Malaysia 2021
Subjects:
Online Access:http://irep.iium.edu.my/113215/7/113215_%20Comparison%20of%20immediate%20effects.pdf
http://irep.iium.edu.my/113215/8/113215_%20Comparison%20of%20immediate%20effects_Scopus.pdf
http://irep.iium.edu.my/113215/
https://medic.upm.edu.my/jurnal_kami/volume_17_2021/mjmhs_vol_17_no_3_july_2021-62220
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.113215
record_format dspace
spelling my.iium.irep.1132152024-07-16T03:08:45Z http://irep.iium.edu.my/113215/ Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics Che Arif, Fatin Amalina Hilmi, Mohd Radzi Mohd Kamal, Khairidzan Ithnin, Mohd. Hafidz RE Ophthalmology Introduction: This study aimed to evaluate the short-term efficacy of two comparable formulation of dual-polymer artificial tears: Systane Hydration preservative (SH) and non-preservative (SHUD) in 60 minutes observation period compared to normal saline. Methods: Fifty participants involved in this prospective, double-masked randomised study. Viscosity and pH of artificial tears were evaluated using rheometer and digital pH-meter prior to tear film assessment. Tear break-up time (TBUT) and tear meniscus height (TMH) were measured at baseline, 5, 15 and 60 minutes after instillation. Tear ferning pattern (TFP) were compared between baseline and 60 minutes after instillation. One-way analysis of variance (ANOVA) and Independent T-test were used to evaluate the effects of SH and SHUD after instillation and comparison between each specific time-interval respectively. P-value of 0.05 was set as the level of significance. Results: The viscosity of SH and SHUD was 26.7cP and 32.73cP re-spectively with pH of 7.85 (SH) and 7.74 (SHUD). Both artificial tears showed significant increment in TBUT between baseline and 15 minutes (SH:5.82±1.063, p=0.01; SHUD:6.02±0.979, p<0.001), and 60 minutes (SH:6.22±0.616, p<0.001; SHUD:6.34±0.658, p<0.001). SHUD demonstrated significant increment in TMH at every measurement taken (0.1996±0.02449, p<0.001 at 5min, 0.2038±0.02276, p<0.001 at 15min and 0.2068±0.02094, p<0.001 at 60min). Likewise, in SH group, significant increment in TMH at 15 minutes (0.1994±0.02325, p<0.001) and 60 minutes (0.2012±0.02379, p<0.001) were noted. Both groups revealed improvement in TFP (both, p<0.001) at 60 minutes. No significant im-provement was noted in control group. Conclusion: Improvement in TMH was prominently faster in SHUD than SH, although both TBUT and TFP revealed comparable tears quality between both artificial tears. Universiti Putra Malaysia 2021-07-17 Article PeerReviewed application/pdf en http://irep.iium.edu.my/113215/7/113215_%20Comparison%20of%20immediate%20effects.pdf application/pdf en http://irep.iium.edu.my/113215/8/113215_%20Comparison%20of%20immediate%20effects_Scopus.pdf Che Arif, Fatin Amalina and Hilmi, Mohd Radzi and Mohd Kamal, Khairidzan and Ithnin, Mohd. Hafidz (2021) Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics. Malaysian Journal of Medicine and Health Sciences, 17 (3). pp. 252-258. ISSN 1675-8544 E-ISSN 2636-9346 https://medic.upm.edu.my/jurnal_kami/volume_17_2021/mjmhs_vol_17_no_3_july_2021-62220
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
description Introduction: This study aimed to evaluate the short-term efficacy of two comparable formulation of dual-polymer artificial tears: Systane Hydration preservative (SH) and non-preservative (SHUD) in 60 minutes observation period compared to normal saline. Methods: Fifty participants involved in this prospective, double-masked randomised study. Viscosity and pH of artificial tears were evaluated using rheometer and digital pH-meter prior to tear film assessment. Tear break-up time (TBUT) and tear meniscus height (TMH) were measured at baseline, 5, 15 and 60 minutes after instillation. Tear ferning pattern (TFP) were compared between baseline and 60 minutes after instillation. One-way analysis of variance (ANOVA) and Independent T-test were used to evaluate the effects of SH and SHUD after instillation and comparison between each specific time-interval respectively. P-value of 0.05 was set as the level of significance. Results: The viscosity of SH and SHUD was 26.7cP and 32.73cP re-spectively with pH of 7.85 (SH) and 7.74 (SHUD). Both artificial tears showed significant increment in TBUT between baseline and 15 minutes (SH:5.82±1.063, p=0.01; SHUD:6.02±0.979, p<0.001), and 60 minutes (SH:6.22±0.616, p<0.001; SHUD:6.34±0.658, p<0.001). SHUD demonstrated significant increment in TMH at every measurement taken (0.1996±0.02449, p<0.001 at 5min, 0.2038±0.02276, p<0.001 at 15min and 0.2068±0.02094, p<0.001 at 60min). Likewise, in SH group, significant increment in TMH at 15 minutes (0.1994±0.02325, p<0.001) and 60 minutes (0.2012±0.02379, p<0.001) were noted. Both groups revealed improvement in TFP (both, p<0.001) at 60 minutes. No significant im-provement was noted in control group. Conclusion: Improvement in TMH was prominently faster in SHUD than SH, although both TBUT and TFP revealed comparable tears quality between both artificial tears.
format Article
author Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
author_facet Che Arif, Fatin Amalina
Hilmi, Mohd Radzi
Mohd Kamal, Khairidzan
Ithnin, Mohd. Hafidz
author_sort Che Arif, Fatin Amalina
title Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
title_short Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
title_full Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
title_fullStr Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
title_full_unstemmed Comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
title_sort comparison of immediate effects on usage of dual polymer artificial tears on changes in tear film characteristics
publisher Universiti Putra Malaysia
publishDate 2021
url http://irep.iium.edu.my/113215/7/113215_%20Comparison%20of%20immediate%20effects.pdf
http://irep.iium.edu.my/113215/8/113215_%20Comparison%20of%20immediate%20effects_Scopus.pdf
http://irep.iium.edu.my/113215/
https://medic.upm.edu.my/jurnal_kami/volume_17_2021/mjmhs_vol_17_no_3_july_2021-62220
_version_ 1805880568024399872