Clinical assessment of watermarked medical images
Problem statement: Digital watermarking provides security to medical images. Watermarking in Region Of Interest (ROI) however distorts medical images but it is known that the resulting loss of fidelity is visually imperceptible. Approach: Clinical assessment will objectively evaluate the distortio...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Science Publications
2009
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/1254/1/Clinical_Assessment_of_Watermarked_Images..pdf http://irep.iium.edu.my/1254/ http://thescipub.com/abstract/10.3844/jcssp.2009.857.863 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.1254 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.12542013-04-26T10:46:38Z http://irep.iium.edu.my/1254/ Clinical assessment of watermarked medical images Mohamad Zain, Jasni Abdul Rani, Mohammed Fauzi Abd. Aziz, Azian QA76 Computer software Problem statement: Digital watermarking provides security to medical images. Watermarking in Region Of Interest (ROI) however distorts medical images but it is known that the resulting loss of fidelity is visually imperceptible. Approach: Clinical assessment will objectively evaluate the distortion on medical images to see whether or not medical diagnosis is altered. We used 75 medical images consisting of x-rays, ultrasound and CT scans. Digital watermarking was inserted in ROI and ROI/Region Of Non Interest (RONI) in all of them. Three assessors were randomly assigned 225 images, each receiving 75, a mixture of watermarked and non watermarked images. Results: Chi square test was used and p<0.05 was considered significant. There was no significant difference between original images and those watermarked in ROI or ROI/RONI. There was no comment on image quality in all the images assessed. Conclusion/Recommendations: Digital watermarking does not alter medical diagnosis when assessed by clinical radiologists. The quality of the watermarked images was also unchanged. Science Publications 2009 Article REM application/pdf en http://irep.iium.edu.my/1254/1/Clinical_Assessment_of_Watermarked_Images..pdf Mohamad Zain, Jasni and Abdul Rani, Mohammed Fauzi and Abd. Aziz, Azian (2009) Clinical assessment of watermarked medical images. Journal of Computer Science, 5 (11). pp. 857-863. ISSN 1549-3636 http://thescipub.com/abstract/10.3844/jcssp.2009.857.863 10.3844/jcssp.2009.857.863 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
QA76 Computer software |
spellingShingle |
QA76 Computer software Mohamad Zain, Jasni Abdul Rani, Mohammed Fauzi Abd. Aziz, Azian Clinical assessment of watermarked medical images |
description |
Problem statement: Digital watermarking provides security to medical images. Watermarking in Region Of Interest (ROI) however distorts medical images but it is known that the
resulting loss of fidelity is visually imperceptible. Approach: Clinical assessment will objectively
evaluate the distortion on medical images to see whether or not medical diagnosis is altered. We used 75 medical images consisting of x-rays, ultrasound and CT scans. Digital watermarking was inserted in ROI and ROI/Region Of Non Interest (RONI) in all of them. Three assessors were randomly assigned 225 images, each receiving 75, a mixture of watermarked and non watermarked images. Results: Chi
square test was used and p<0.05 was considered significant. There was no significant difference between original images and those watermarked in ROI or ROI/RONI. There was no comment on image quality in all the images assessed. Conclusion/Recommendations: Digital watermarking does
not alter medical diagnosis when assessed by clinical radiologists. The quality of the watermarked
images was also unchanged. |
format |
Article |
author |
Mohamad Zain, Jasni Abdul Rani, Mohammed Fauzi Abd. Aziz, Azian |
author_facet |
Mohamad Zain, Jasni Abdul Rani, Mohammed Fauzi Abd. Aziz, Azian |
author_sort |
Mohamad Zain, Jasni |
title |
Clinical assessment of watermarked medical images |
title_short |
Clinical assessment of watermarked medical images |
title_full |
Clinical assessment of watermarked medical images |
title_fullStr |
Clinical assessment of watermarked medical images |
title_full_unstemmed |
Clinical assessment of watermarked medical images |
title_sort |
clinical assessment of watermarked medical images |
publisher |
Science Publications |
publishDate |
2009 |
url |
http://irep.iium.edu.my/1254/1/Clinical_Assessment_of_Watermarked_Images..pdf http://irep.iium.edu.my/1254/ http://thescipub.com/abstract/10.3844/jcssp.2009.857.863 |
_version_ |
1643604747369840640 |