Pollution load management to improve water quality of Sungai Pusu

Sg. Pusu is a river that flows through the campus of the International Islamic University Malaysia (IIUM). The river is murky in appearance, particularly after a rainfall event, which reflects elevated suspended solids (SS) levels. This study aims to characterize the water quality conditions of the...

Full description

Saved in:
Bibliographic Details
Main Authors: Zainudin, Zaki, Mohd Said, Noorwahidah Syaira, Jami, Mohammed Saedi, Salleh, Md. Noor
Format: Article
Language:English
Published: AENSI Publications 2014
Subjects:
Online Access:http://irep.iium.edu.my/36398/1/549-552.pdf
http://irep.iium.edu.my/36398/
http://www.aensiweb.com/aeb/2014/549-552.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.36398
record_format dspace
spelling my.iium.irep.36398 http://irep.iium.edu.my/36398/ Pollution load management to improve water quality of Sungai Pusu Zainudin, Zaki Mohd Said, Noorwahidah Syaira Jami, Mohammed Saedi Salleh, Md. Noor TC401 River, lake, and water-supply engineering (General) TD Environmental technology. Sanitary engineering TD201 Water supply for domestic and industrial purposes Sg. Pusu is a river that flows through the campus of the International Islamic University Malaysia (IIUM). The river is murky in appearance, particularly after a rainfall event, which reflects elevated suspended solids (SS) levels. This study aims to characterize the water quality conditions of the river under high flow conditions, particularly in relation to SS, via a QUAL2K modeling approach and to determine the amount of load reduction needed to a achieve a Class II denotation of the National Water Quality Standards (NWQS). A total of 30 water quality stations were identified on the main-stem and east tributary for grab sample collection. The analysis results showed the SS levels ranged between 10 – 1,790 mg/L on the main-stem, whereas the levels were generally higher in the tributary, ranging between 10 – 140 mg/L. The increase was most significant in the middle segment of the river, where the levels went beyond 500 mg/L. The modeling revealed that at least 2,880 kg/hr of SS had to be reduced to achieve the Class II target. Sand-mining and developmental activities upstream were the primary source of SS. Besides this; BOD5 and NH3-N levels were also elevated, beyond the Class IV denotation. To achieve Class II, at least 122 kg/hr of BOD5 and 42 kg/hr of NH3-N have to be reduced. AENSI Publications 2014-03-01 Article PeerReviewed application/pdf en http://irep.iium.edu.my/36398/1/549-552.pdf Zainudin, Zaki and Mohd Said, Noorwahidah Syaira and Jami, Mohammed Saedi and Salleh, Md. Noor (2014) Pollution load management to improve water quality of Sungai Pusu. Advances in Environmental Biology, 8 (3). pp. 549-552. ISSN 1995-0756 http://www.aensiweb.com/aeb/2014/549-552.pdf
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic TC401 River, lake, and water-supply engineering (General)
TD Environmental technology. Sanitary engineering
TD201 Water supply for domestic and industrial purposes
spellingShingle TC401 River, lake, and water-supply engineering (General)
TD Environmental technology. Sanitary engineering
TD201 Water supply for domestic and industrial purposes
Zainudin, Zaki
Mohd Said, Noorwahidah Syaira
Jami, Mohammed Saedi
Salleh, Md. Noor
Pollution load management to improve water quality of Sungai Pusu
description Sg. Pusu is a river that flows through the campus of the International Islamic University Malaysia (IIUM). The river is murky in appearance, particularly after a rainfall event, which reflects elevated suspended solids (SS) levels. This study aims to characterize the water quality conditions of the river under high flow conditions, particularly in relation to SS, via a QUAL2K modeling approach and to determine the amount of load reduction needed to a achieve a Class II denotation of the National Water Quality Standards (NWQS). A total of 30 water quality stations were identified on the main-stem and east tributary for grab sample collection. The analysis results showed the SS levels ranged between 10 – 1,790 mg/L on the main-stem, whereas the levels were generally higher in the tributary, ranging between 10 – 140 mg/L. The increase was most significant in the middle segment of the river, where the levels went beyond 500 mg/L. The modeling revealed that at least 2,880 kg/hr of SS had to be reduced to achieve the Class II target. Sand-mining and developmental activities upstream were the primary source of SS. Besides this; BOD5 and NH3-N levels were also elevated, beyond the Class IV denotation. To achieve Class II, at least 122 kg/hr of BOD5 and 42 kg/hr of NH3-N have to be reduced.
format Article
author Zainudin, Zaki
Mohd Said, Noorwahidah Syaira
Jami, Mohammed Saedi
Salleh, Md. Noor
author_facet Zainudin, Zaki
Mohd Said, Noorwahidah Syaira
Jami, Mohammed Saedi
Salleh, Md. Noor
author_sort Zainudin, Zaki
title Pollution load management to improve water quality of Sungai Pusu
title_short Pollution load management to improve water quality of Sungai Pusu
title_full Pollution load management to improve water quality of Sungai Pusu
title_fullStr Pollution load management to improve water quality of Sungai Pusu
title_full_unstemmed Pollution load management to improve water quality of Sungai Pusu
title_sort pollution load management to improve water quality of sungai pusu
publisher AENSI Publications
publishDate 2014
url http://irep.iium.edu.my/36398/1/549-552.pdf
http://irep.iium.edu.my/36398/
http://www.aensiweb.com/aeb/2014/549-552.pdf
_version_ 1643616598519447552