CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation

ABSTRACT Poor hygrothermal performance exacerbates deterioration risk from mould growth, corrosion and damage to archival materials. Improved microcomputers’ computational power has significantly advanced computational fluid dynamics (CFD) models and research developments in indoor airflow, heat tr...

Full description

Saved in:
Bibliographic Details
Main Authors: Oladokun, Majeed, Ali, Maisarah, Osman, Samsul Bahrin, Samsuddin, Niza, Hamzah, Hairul Aini, Salleh, Md. Noor
Format: Conference or Workshop Item
Language:English
English
Published: 2015
Subjects:
Online Access:http://irep.iium.edu.my/44413/1/44413_abstract.pdf
http://irep.iium.edu.my/44413/4/CFDRI2015_Paper_ID_1184_Finalnov2015.pdf
http://irep.iium.edu.my/44413/
http://cfdri.uthm.edu.my
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.44413
record_format dspace
spelling my.iium.irep.444132018-04-16T01:28:37Z http://irep.iium.edu.my/44413/ CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation Oladokun, Majeed Ali, Maisarah Osman, Samsul Bahrin Samsuddin, Niza Hamzah, Hairul Aini Salleh, Md. Noor TH7005 Heating and ventilation ABSTRACT Poor hygrothermal performance exacerbates deterioration risk from mould growth, corrosion and damage to archival materials. Improved microcomputers’ computational power has significantly advanced computational fluid dynamics (CFD) models and research developments in indoor airflow, heat transfer and contaminant transport. Nevertheless, numerous uncertainties exist in the CFD experiments which require adequate clarifications for improved results’ reliability. This paper presents the measurement and validation of a CFD model for the investigation of the hygrothermal performance in an indoor environment with known cases of microbial proliferations. The room, 5.2 m × 4.8 m × 3.0 m high, is air-conditioned and ventilated by constant air volume (CAV) system controlling the indoor airflow and hygrothermal profiles with ceiling mounted four-way supply diffuser and extract grille for indoor air distribution. The methodology combines in-situ experiment and numerical simulation with a commercial CFD tool using the standard k–ε model. Microclimate and airflow parameters obtained from in-situ experiments were used as boundary conditions in the CFD. The study shows a good agreement between the predicted and measured indoor hygrothermal profile with less than 10% deviation. The results indicate that the model can be employed for further investigation with high confidence. Keywords: CFD Simulation In-situ Experiments Indoor Climate Hygrothermal performance Uncertainty Assessment 2015 Conference or Workshop Item REM application/pdf en http://irep.iium.edu.my/44413/1/44413_abstract.pdf application/pdf en http://irep.iium.edu.my/44413/4/CFDRI2015_Paper_ID_1184_Finalnov2015.pdf Oladokun, Majeed and Ali, Maisarah and Osman, Samsul Bahrin and Samsuddin, Niza and Hamzah, Hairul Aini and Salleh, Md. Noor (2015) CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation. In: International Conference on Computational Fluid Dynamics in Research and Industry 2015, 17-19 August 2015, Kuala Lumpur. http://cfdri.uthm.edu.my
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic TH7005 Heating and ventilation
spellingShingle TH7005 Heating and ventilation
Oladokun, Majeed
Ali, Maisarah
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
description ABSTRACT Poor hygrothermal performance exacerbates deterioration risk from mould growth, corrosion and damage to archival materials. Improved microcomputers’ computational power has significantly advanced computational fluid dynamics (CFD) models and research developments in indoor airflow, heat transfer and contaminant transport. Nevertheless, numerous uncertainties exist in the CFD experiments which require adequate clarifications for improved results’ reliability. This paper presents the measurement and validation of a CFD model for the investigation of the hygrothermal performance in an indoor environment with known cases of microbial proliferations. The room, 5.2 m × 4.8 m × 3.0 m high, is air-conditioned and ventilated by constant air volume (CAV) system controlling the indoor airflow and hygrothermal profiles with ceiling mounted four-way supply diffuser and extract grille for indoor air distribution. The methodology combines in-situ experiment and numerical simulation with a commercial CFD tool using the standard k–ε model. Microclimate and airflow parameters obtained from in-situ experiments were used as boundary conditions in the CFD. The study shows a good agreement between the predicted and measured indoor hygrothermal profile with less than 10% deviation. The results indicate that the model can be employed for further investigation with high confidence. Keywords: CFD Simulation In-situ Experiments Indoor Climate Hygrothermal performance Uncertainty Assessment
format Conference or Workshop Item
author Oladokun, Majeed
Ali, Maisarah
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
author_facet Oladokun, Majeed
Ali, Maisarah
Osman, Samsul Bahrin
Samsuddin, Niza
Hamzah, Hairul Aini
Salleh, Md. Noor
author_sort Oladokun, Majeed
title CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
title_short CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
title_full CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
title_fullStr CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
title_full_unstemmed CFD investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
title_sort cfd investigation of indoor hygrothermal performance in academic research storage room: measurement and validation
publishDate 2015
url http://irep.iium.edu.my/44413/1/44413_abstract.pdf
http://irep.iium.edu.my/44413/4/CFDRI2015_Paper_ID_1184_Finalnov2015.pdf
http://irep.iium.edu.my/44413/
http://cfdri.uthm.edu.my
_version_ 1643612569560154112