Control of base flows with micro jets
This paper presents the results of an experimental investigation carried out to control the base pressure in a suddenly expanded axi-symmetric passage. Active control in the form of micro jets was employed to control the base pressure. Air injection at four locations at the base, symmetric to t...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Walter de Gruyter
2011
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/46687/1/ijtkhan.pdf http://irep.iium.edu.my/46687/ http://www.degruyter.com/view/j/tjj.2011.28.issue-1/tjj.2011.009/tjj.2011.009.xml?format=INT |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.46687 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.466872016-07-20T01:14:52Z http://irep.iium.edu.my/46687/ Control of base flows with micro jets Ahmed Ali Baig, Maughal Al-Mufadi, Farhad Khan, Sher Afghan Rathakrishnan, Ethirajan TL500 Aeronautics This paper presents the results of an experimental investigation carried out to control the base pressure in a suddenly expanded axi-symmetric passage. Active control in the form of micro jets was employed to control the base pressure. Air injection at four locations at the base, symmetric to the nozzle axis was used as the active control. The jet Mach numbers at the entry to the suddenly expanded duct studied were 1.87, 2.2 and 2.58. The area ratio of the present study was 2.56. The length-to-diameter ratio of the suddenly expanded duct varied from 10 to 1. Nozzles generating the above jet Mach numbers were operated with nozzle pressure ratio (NPR) in the range 3 to 11. In addition to base pressure, wall pressure field along the duct was also studied. It is found that the active control in the form of blowing through small orifices (micro jets) are effective in controlling the base pressure field. As high as 65 percent increase in base pressure was achieved for certain combination of parameters of the present study. Micro jets do not disturb the flow field in the enlarged duct. Walter de Gruyter 2011-01 Article REM application/pdf en http://irep.iium.edu.my/46687/1/ijtkhan.pdf Ahmed Ali Baig, Maughal and Al-Mufadi, Farhad and Khan, Sher Afghan and Rathakrishnan, Ethirajan (2011) Control of base flows with micro jets. International Journal of Turbo & Jet-Engines, 28 (1). pp. 59-69. ISSN 0334-0082 http://www.degruyter.com/view/j/tjj.2011.28.issue-1/tjj.2011.009/tjj.2011.009.xml?format=INT 10.1515/tjj.2011.009. |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
TL500 Aeronautics |
spellingShingle |
TL500 Aeronautics Ahmed Ali Baig, Maughal Al-Mufadi, Farhad Khan, Sher Afghan Rathakrishnan, Ethirajan Control of base flows with micro jets |
description |
This paper presents the results of an experimental
investigation carried out to control the base pressure in
a suddenly expanded axi-symmetric passage. Active control
in the form of micro jets was employed to control the
base pressure. Air injection at four locations at the base,
symmetric to the nozzle axis was used as the active control.
The jet Mach numbers at the entry to the suddenly
expanded duct studied were 1.87, 2.2 and 2.58. The area
ratio of the present study was 2.56. The length-to-diameter
ratio of the suddenly expanded duct varied from 10 to 1.
Nozzles generating the above jet Mach numbers were operated
with nozzle pressure ratio (NPR) in the range 3 to 11.
In addition to base pressure, wall pressure field along the
duct was also studied. It is found that the active control in
the form of blowing through small orifices (micro jets) are
effective in controlling the base pressure field. As high as
65 percent increase in base pressure was achieved for certain
combination of parameters of the present study. Micro
jets do not disturb the flow field in the enlarged duct. |
format |
Article |
author |
Ahmed Ali Baig, Maughal Al-Mufadi, Farhad Khan, Sher Afghan Rathakrishnan, Ethirajan |
author_facet |
Ahmed Ali Baig, Maughal Al-Mufadi, Farhad Khan, Sher Afghan Rathakrishnan, Ethirajan |
author_sort |
Ahmed Ali Baig, Maughal |
title |
Control of base flows with micro jets |
title_short |
Control of base flows with micro jets |
title_full |
Control of base flows with micro jets |
title_fullStr |
Control of base flows with micro jets |
title_full_unstemmed |
Control of base flows with micro jets |
title_sort |
control of base flows with micro jets |
publisher |
Walter de Gruyter |
publishDate |
2011 |
url |
http://irep.iium.edu.my/46687/1/ijtkhan.pdf http://irep.iium.edu.my/46687/ http://www.degruyter.com/view/j/tjj.2011.28.issue-1/tjj.2011.009/tjj.2011.009.xml?format=INT |
_version_ |
1643613043751387136 |