Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration

Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To...

Full description

Saved in:
Bibliographic Details
Main Authors: Kato, Yuki, Motohara, Shosaku, Ohmuta, Takao, Noor Azmi, Azran Azhim, Ueno, Akinori
Format: Article
Language:English
English
Published: Institute of Electrical Engineers of Japan 2017
Subjects:
Online Access:http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf
http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf
http://irep.iium.edu.my/46758/
https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.46758
record_format dspace
spelling my.iium.irep.467582018-04-16T08:04:15Z http://irep.iium.edu.my/46758/ Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration Kato, Yuki Motohara, Shosaku Ohmuta, Takao Noor Azmi, Azran Azhim Ueno, Akinori TP248.13 Biotechnology Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To obtain clear ECG, high stability is required for the electrocardiograph using capacitive-coupled electrode. In this study, tolerance of capacitive wearable chest-belt electrocardiograph was tested for the electrostatic and movement artifacts. A constant electrostatic artifact was discharged repeatedly on three types of electrode having different shielding configurations, and their transient responses were compared in terms of deviation area, transient slope and recovery time. The results revealed the best tolerance of doubly-shielded five-layered electrode. The best performed five-layered electrode was used for exercise tolerance test. Then, detection rates of R-wave and T-wave of ECG, and standard deviation of base line of the recordings were calculated as tolerance indices and compared to those obtained by commercial disposable electrode. Although R-wave detection rate of the five-layered electrode decreased by 2.0%, the rate of T-wave was comparable to those of the disposable electrode. Furthermore, the standard deviation of the base line was significantly smaller than that of the disposable electrode (p<0.01). Institute of Electrical Engineers of Japan 2017 Article REM application/pdf en http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf application/pdf en http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf Kato, Yuki and Motohara, Shosaku and Ohmuta, Takao and Noor Azmi, Azran Azhim and Ueno, Akinori (2017) Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration. IEEJ Transactions on Electronics, Information and Systems, 137 (4). pp. 607-615. ISSN 0385-4221 https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article 10.1541/ieejeiss.137.607
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic TP248.13 Biotechnology
spellingShingle TP248.13 Biotechnology
Kato, Yuki
Motohara, Shosaku
Ohmuta, Takao
Noor Azmi, Azran Azhim
Ueno, Akinori
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
description Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To obtain clear ECG, high stability is required for the electrocardiograph using capacitive-coupled electrode. In this study, tolerance of capacitive wearable chest-belt electrocardiograph was tested for the electrostatic and movement artifacts. A constant electrostatic artifact was discharged repeatedly on three types of electrode having different shielding configurations, and their transient responses were compared in terms of deviation area, transient slope and recovery time. The results revealed the best tolerance of doubly-shielded five-layered electrode. The best performed five-layered electrode was used for exercise tolerance test. Then, detection rates of R-wave and T-wave of ECG, and standard deviation of base line of the recordings were calculated as tolerance indices and compared to those obtained by commercial disposable electrode. Although R-wave detection rate of the five-layered electrode decreased by 2.0%, the rate of T-wave was comparable to those of the disposable electrode. Furthermore, the standard deviation of the base line was significantly smaller than that of the disposable electrode (p<0.01).
format Article
author Kato, Yuki
Motohara, Shosaku
Ohmuta, Takao
Noor Azmi, Azran Azhim
Ueno, Akinori
author_facet Kato, Yuki
Motohara, Shosaku
Ohmuta, Takao
Noor Azmi, Azran Azhim
Ueno, Akinori
author_sort Kato, Yuki
title Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
title_short Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
title_full Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
title_fullStr Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
title_full_unstemmed Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
title_sort artifact tolerance test for capacitive wearable chest-belt electrocardiograph - effect of electrode configuration
publisher Institute of Electrical Engineers of Japan
publishDate 2017
url http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf
http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf
http://irep.iium.edu.my/46758/
https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article
_version_ 1643613056209518592