Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration
Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Institute of Electrical Engineers of Japan
2017
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf http://irep.iium.edu.my/46758/ https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English English |
id |
my.iium.irep.46758 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.467582018-04-16T08:04:15Z http://irep.iium.edu.my/46758/ Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration Kato, Yuki Motohara, Shosaku Ohmuta, Takao Noor Azmi, Azran Azhim Ueno, Akinori TP248.13 Biotechnology Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To obtain clear ECG, high stability is required for the electrocardiograph using capacitive-coupled electrode. In this study, tolerance of capacitive wearable chest-belt electrocardiograph was tested for the electrostatic and movement artifacts. A constant electrostatic artifact was discharged repeatedly on three types of electrode having different shielding configurations, and their transient responses were compared in terms of deviation area, transient slope and recovery time. The results revealed the best tolerance of doubly-shielded five-layered electrode. The best performed five-layered electrode was used for exercise tolerance test. Then, detection rates of R-wave and T-wave of ECG, and standard deviation of base line of the recordings were calculated as tolerance indices and compared to those obtained by commercial disposable electrode. Although R-wave detection rate of the five-layered electrode decreased by 2.0%, the rate of T-wave was comparable to those of the disposable electrode. Furthermore, the standard deviation of the base line was significantly smaller than that of the disposable electrode (p<0.01). Institute of Electrical Engineers of Japan 2017 Article REM application/pdf en http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf application/pdf en http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf Kato, Yuki and Motohara, Shosaku and Ohmuta, Takao and Noor Azmi, Azran Azhim and Ueno, Akinori (2017) Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration. IEEJ Transactions on Electronics, Information and Systems, 137 (4). pp. 607-615. ISSN 0385-4221 https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article 10.1541/ieejeiss.137.607 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English English |
topic |
TP248.13 Biotechnology |
spellingShingle |
TP248.13 Biotechnology Kato, Yuki Motohara, Shosaku Ohmuta, Takao Noor Azmi, Azran Azhim Ueno, Akinori Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
description |
Electrocardiogram (ECG) provides useful information for the diagnosis of cardiovascular disease. In capacitive-coupled ECG sensing, electrostatic artifact and movement artifact become serious problems. In particular, low frequency components such as T wave of ECG are susceptible to the artifacts. To obtain clear ECG, high stability is required for the electrocardiograph using capacitive-coupled electrode. In this study, tolerance of capacitive wearable chest-belt electrocardiograph was tested for the electrostatic and movement artifacts. A constant electrostatic artifact was discharged repeatedly on three types of electrode having different shielding configurations, and their transient responses were compared in terms of deviation area, transient slope and recovery time. The results revealed the best tolerance of doubly-shielded five-layered electrode. The best performed five-layered electrode was used for exercise tolerance test. Then, detection rates of R-wave and T-wave of ECG, and standard deviation of base line of the recordings were calculated as tolerance indices and compared to those obtained by commercial disposable electrode. Although R-wave detection rate of the five-layered electrode decreased by 2.0%, the rate of T-wave was comparable to those of the disposable electrode. Furthermore, the standard deviation of the base line was significantly smaller than that of the disposable electrode (p<0.01). |
format |
Article |
author |
Kato, Yuki Motohara, Shosaku Ohmuta, Takao Noor Azmi, Azran Azhim Ueno, Akinori |
author_facet |
Kato, Yuki Motohara, Shosaku Ohmuta, Takao Noor Azmi, Azran Azhim Ueno, Akinori |
author_sort |
Kato, Yuki |
title |
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
title_short |
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
title_full |
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
title_fullStr |
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
title_full_unstemmed |
Artifact tolerance test for capacitive wearable chest-belt electrocardiograph - Effect of electrode configuration |
title_sort |
artifact tolerance test for capacitive wearable chest-belt electrocardiograph - effect of electrode configuration |
publisher |
Institute of Electrical Engineers of Japan |
publishDate |
2017 |
url |
http://irep.iium.edu.my/46758/18/46758_%20Artifact%20tolerance%20test.pdf http://irep.iium.edu.my/46758/13/46758_Artifact%20tolerance%20test%20for%20capacitive%20wearable%20chest-belt_scopus.pdf http://irep.iium.edu.my/46758/ https://www.jstage.jst.go.jp/article/ieejeiss/137/4/137_607/_article |
_version_ |
1643613056209518592 |