Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped silica telecommunication fibres (...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier Limited
2015
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf http://irep.iium.edu.my/55552/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.55552 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.555522017-02-13T16:35:27Z http://irep.iium.edu.my/55552/ Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles Ahmad Shaharuddin, Siti Shafiqah Yusoff, Mohd Amin Md Nor, Roslan D.A, Bradley QC Physics We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped silica telecommunication fibres (SMF) and tailor-made doped photonic crystal fibres (PCFc), the latter Ge-doped or also co-doped with boron. The PCFs are formed of capillaries that at high temperatures and under vacuum are made to collapse inwards (PCFc), the internal walls fusing and generating strain-related defects. To-date, the fabricated PCFc-Ge-B, PCFc-Ge and (SMF) have been observed to provide TL yields which weight-for-weight are some 15, 10 and 2 × that of TLD-100. In present study we test the linearity of TL yield for x-ray doses from 0.1- to 10 mGy, use being made of an x-ray tube operated at 80 kVp, a value typically selected in chest radiography. For a dose of 10 mGy, a study of energy dependence has been conducted using x-ray tube potentials of 80 kVp 100 kVp, and 120 kVp, with inherent filtration 0.9 mm Al measured at 75 kVp, and total filtration of 2.8 mm Al at 80 kVp. Elsevier Limited 2015-08-15 Article REM application/pdf en http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf Ahmad Shaharuddin, Siti Shafiqah and Yusoff, Mohd Amin and Md Nor, Roslan and D.A, Bradley (2015) Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles. Radiation Physics and Chemistry. ISSN 0969-806X (In Press) |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
QC Physics |
spellingShingle |
QC Physics Ahmad Shaharuddin, Siti Shafiqah Yusoff, Mohd Amin Md Nor, Roslan D.A, Bradley Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
description |
We focus on the development of Ge-doped silica thermoluminescent dosimeters with
sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic
imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped
silica telecommunication fibres (SMF) and tailor-made doped photonic crystal fibres (PCFc),
the latter Ge-doped or also co-doped with boron. The PCFs are formed of capillaries that at
high temperatures and under vacuum are made to collapse inwards (PCFc), the internal walls
fusing and generating strain-related defects. To-date, the fabricated PCFc-Ge-B, PCFc-Ge
and (SMF) have been observed to provide TL yields which weight-for-weight are some 15,
10 and 2 × that of TLD-100. In present study we test the linearity of TL yield for x-ray doses
from 0.1- to 10 mGy, use being made of an x-ray tube operated at 80 kVp, a value typically
selected in chest radiography. For a dose of 10 mGy, a study of energy dependence has been
conducted using x-ray tube potentials of 80 kVp 100 kVp, and 120 kVp, with inherent
filtration 0.9 mm Al measured at 75 kVp, and total filtration of 2.8 mm Al at 80 kVp. |
format |
Article |
author |
Ahmad Shaharuddin, Siti Shafiqah Yusoff, Mohd Amin Md Nor, Roslan D.A, Bradley |
author_facet |
Ahmad Shaharuddin, Siti Shafiqah Yusoff, Mohd Amin Md Nor, Roslan D.A, Bradley |
author_sort |
Ahmad Shaharuddin, Siti Shafiqah |
title |
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
title_short |
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
title_full |
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
title_fullStr |
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
title_full_unstemmed |
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles |
title_sort |
effect of particle size on the thermoluminescence (tl) response of silica nanoparticles |
publisher |
Elsevier Limited |
publishDate |
2015 |
url |
http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf http://irep.iium.edu.my/55552/ |
_version_ |
1643614763787223040 |