Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles

We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped silica telecommunication fibres (...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmad Shaharuddin, Siti Shafiqah, Yusoff, Mohd Amin, Md Nor, Roslan, D.A, Bradley
Format: Article
Language:English
Published: Elsevier Limited 2015
Subjects:
Online Access:http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf
http://irep.iium.edu.my/55552/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.55552
record_format dspace
spelling my.iium.irep.555522017-02-13T16:35:27Z http://irep.iium.edu.my/55552/ Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles Ahmad Shaharuddin, Siti Shafiqah Yusoff, Mohd Amin Md Nor, Roslan D.A, Bradley QC Physics We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped silica telecommunication fibres (SMF) and tailor-made doped photonic crystal fibres (PCFc), the latter Ge-doped or also co-doped with boron. The PCFs are formed of capillaries that at high temperatures and under vacuum are made to collapse inwards (PCFc), the internal walls fusing and generating strain-related defects. To-date, the fabricated PCFc-Ge-B, PCFc-Ge and (SMF) have been observed to provide TL yields which weight-for-weight are some 15, 10 and 2 × that of TLD-100. In present study we test the linearity of TL yield for x-ray doses from 0.1- to 10 mGy, use being made of an x-ray tube operated at 80 kVp, a value typically selected in chest radiography. For a dose of 10 mGy, a study of energy dependence has been conducted using x-ray tube potentials of 80 kVp 100 kVp, and 120 kVp, with inherent filtration 0.9 mm Al measured at 75 kVp, and total filtration of 2.8 mm Al at 80 kVp. Elsevier Limited 2015-08-15 Article REM application/pdf en http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf Ahmad Shaharuddin, Siti Shafiqah and Yusoff, Mohd Amin and Md Nor, Roslan and D.A, Bradley (2015) Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles. Radiation Physics and Chemistry. ISSN 0969-806X (In Press)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic QC Physics
spellingShingle QC Physics
Ahmad Shaharuddin, Siti Shafiqah
Yusoff, Mohd Amin
Md Nor, Roslan
D.A, Bradley
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
description We focus on the development of Ge-doped silica thermoluminescent dosimeters with sensitivity superior to that of the LiF (Mg,Ti) phosphors popularly used in x-ray diagnostic imaging dosimetry, typically in the form of the product TLD-100. Of interest are Ge-doped silica telecommunication fibres (SMF) and tailor-made doped photonic crystal fibres (PCFc), the latter Ge-doped or also co-doped with boron. The PCFs are formed of capillaries that at high temperatures and under vacuum are made to collapse inwards (PCFc), the internal walls fusing and generating strain-related defects. To-date, the fabricated PCFc-Ge-B, PCFc-Ge and (SMF) have been observed to provide TL yields which weight-for-weight are some 15, 10 and 2 × that of TLD-100. In present study we test the linearity of TL yield for x-ray doses from 0.1- to 10 mGy, use being made of an x-ray tube operated at 80 kVp, a value typically selected in chest radiography. For a dose of 10 mGy, a study of energy dependence has been conducted using x-ray tube potentials of 80 kVp 100 kVp, and 120 kVp, with inherent filtration 0.9 mm Al measured at 75 kVp, and total filtration of 2.8 mm Al at 80 kVp.
format Article
author Ahmad Shaharuddin, Siti Shafiqah
Yusoff, Mohd Amin
Md Nor, Roslan
D.A, Bradley
author_facet Ahmad Shaharuddin, Siti Shafiqah
Yusoff, Mohd Amin
Md Nor, Roslan
D.A, Bradley
author_sort Ahmad Shaharuddin, Siti Shafiqah
title Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
title_short Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
title_full Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
title_fullStr Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
title_full_unstemmed Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
title_sort effect of particle size on the thermoluminescence (tl) response of silica nanoparticles
publisher Elsevier Limited
publishDate 2015
url http://irep.iium.edu.my/55552/1/Effect%20of%20particle%20size%20on%20the%20thermoluminescence%20%28TL%29%20response%20of%20silica.pdf
http://irep.iium.edu.my/55552/
_version_ 1643614763787223040