A non-contact capacitance type level transducer for liquid characterization
The liquid properties such as buoyancy, pressure at a depth, relative electrical permittivity, electrical conductivity, thermal conductivity, absorption of radiation, liquid surface reflection of sound or light waves, are used to design the different types of liquid level transducers for l...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2008
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/5798/1/04580808.pdf http://irep.iium.edu.my/5798/ http://dx.doi.org/10.1109/ICCCE.2008.4580808 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Islam Antarabangsa Malaysia |
Language: | English |
id |
my.iium.irep.5798 |
---|---|
record_format |
dspace |
spelling |
my.iium.irep.57982020-12-16T00:22:00Z http://irep.iium.edu.my/5798/ A non-contact capacitance type level transducer for liquid characterization Khan, Sheroz Htike, Kyaw Kyaw Alam, A. H. M. Zahirul Islam, Md. Rafiqul Khalifa, Othman Omran Khan, Saman S. T Technology (General) The liquid properties such as buoyancy, pressure at a depth, relative electrical permittivity, electrical conductivity, thermal conductivity, absorption of radiation, liquid surface reflection of sound or light waves, are used to design the different types of liquid level transducers for liquid level measurement in any process industry. The contact-type level-sensing transducers have the disadvantage that their characteristic properties may change due to physical or chemical reaction between the liquid and the probing material, and hence may affect accuracy besides their life time. The non-contact-type level-sensing probes may have longer life period, but they are comparatively costly and require various environmental and experimental precautionary measures when being used. In this paper, a low-cost non-contact capacitance type liquid level measuring technique has been designed and used for liquid identification objectives. The results obtained are very much consistent with the theoretical derivations. 2008 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/5798/1/04580808.pdf Khan, Sheroz and Htike, Kyaw Kyaw and Alam, A. H. M. Zahirul and Islam, Md. Rafiqul and Khalifa, Othman Omran and Khan, Saman S. (2008) A non-contact capacitance type level transducer for liquid characterization. In: International Conference on Computer and Communication Engineering 2008, May 13-15, 2008 , Kuala Lumpur, Malaysia. http://dx.doi.org/10.1109/ICCCE.2008.4580808 doi:10.1109/ICCCE.2008.4580808 |
institution |
Universiti Islam Antarabangsa Malaysia |
building |
IIUM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
International Islamic University Malaysia |
content_source |
IIUM Repository (IREP) |
url_provider |
http://irep.iium.edu.my/ |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Khan, Sheroz Htike, Kyaw Kyaw Alam, A. H. M. Zahirul Islam, Md. Rafiqul Khalifa, Othman Omran Khan, Saman S. A non-contact capacitance type level transducer for liquid characterization |
description |
The liquid properties such as buoyancy, pressure at
a depth, relative electrical permittivity, electrical
conductivity, thermal conductivity, absorption of
radiation, liquid surface reflection of sound or light
waves, are used to design the different types of liquid
level transducers for liquid level measurement in any
process industry. The contact-type level-sensing
transducers have the disadvantage that their
characteristic properties may change due to physical
or chemical reaction between the liquid and the
probing material, and hence may affect accuracy
besides their life time.
The non-contact-type level-sensing probes may
have longer life period, but they are comparatively
costly and require various environmental and
experimental precautionary measures when being
used.
In this paper, a low-cost non-contact capacitance
type liquid level measuring technique has been
designed and used for liquid identification objectives.
The results obtained are very much consistent with the
theoretical derivations. |
format |
Conference or Workshop Item |
author |
Khan, Sheroz Htike, Kyaw Kyaw Alam, A. H. M. Zahirul Islam, Md. Rafiqul Khalifa, Othman Omran Khan, Saman S. |
author_facet |
Khan, Sheroz Htike, Kyaw Kyaw Alam, A. H. M. Zahirul Islam, Md. Rafiqul Khalifa, Othman Omran Khan, Saman S. |
author_sort |
Khan, Sheroz |
title |
A non-contact capacitance type level transducer for liquid characterization |
title_short |
A non-contact capacitance type level transducer for liquid characterization |
title_full |
A non-contact capacitance type level transducer for liquid characterization |
title_fullStr |
A non-contact capacitance type level transducer for liquid characterization |
title_full_unstemmed |
A non-contact capacitance type level transducer for liquid characterization |
title_sort |
non-contact capacitance type level transducer for liquid characterization |
publishDate |
2008 |
url |
http://irep.iium.edu.my/5798/1/04580808.pdf http://irep.iium.edu.my/5798/ http://dx.doi.org/10.1109/ICCCE.2008.4580808 |
_version_ |
1687393054459166720 |