Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report

Background: Thyroid hormone assay interference is often misdiagnosed. Is has deep impact onto patient’s care as wrong interpretation of the results leads to wrong intervention. This case is to highlight the importance of recognizing immunoassay interference for thyroid stimulating-hormone (TSH) cong...

Full description

Saved in:
Bibliographic Details
Main Authors: Goh, Kian Guan, Zakaria, Miza Hiryanti, Shahar, Mohammad Arif, Omar, Ahmad Marzuki
Format: Conference or Workshop Item
Language:English
English
Published: 2017
Subjects:
Online Access:http://irep.iium.edu.my/58566/1/TSH%20assay%20interference.pdf
http://irep.iium.edu.my/58566/2/TAI%20poster%20ver%201.0.pdf
http://irep.iium.edu.my/58566/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
English
id my.iium.irep.58566
record_format dspace
spelling my.iium.irep.585662017-11-20T02:58:16Z http://irep.iium.edu.my/58566/ Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report Goh, Kian Guan Zakaria, Miza Hiryanti Shahar, Mohammad Arif Omar, Ahmad Marzuki R Medicine (General) RC Internal medicine Background: Thyroid hormone assay interference is often misdiagnosed. Is has deep impact onto patient’s care as wrong interpretation of the results leads to wrong intervention. This case is to highlight the importance of recognizing immunoassay interference for thyroid stimulating-hormone (TSH) congenital hypothyroidism. Case report: the patient is a 22-year-old university student with congenital hypothyroidism, diagnosed at age 10 due to poor growth velocity and constipation. Sha was put on L-thyroxine replacement since diagnosis. Despite small body habitus (weight 42 kg and height 153,5 cm) she was on 1125 mcg of L-thyroxine per week (3.83 mcg/kg/day) due to persistently high TSH (8.558 uIU/mL) despite normal free T4 (19.47 pmol/L) and clinically euthyroid. There were episodes of iatrogenic hyperthyroidism due to over-replacement of L-thyroxine (free T4 48.96 pmol/L) and patient became thyrotoxic clinically. There were wide fluctuations of TSH reading (1.086 – 99.076 uIU/mL) despite normal free T4 values (10.66 – 17.1 pmol/L) and normal free T3 (4.6 pmol/L). Her thyroid function was repeated in different labs and showed relatively normal thyroid function (free T4 15.7 pmol/L and TSH 0.76 uIU/mL). Discussion: Thyroid hormone assay interference is a recognized entity in clinical laboratory settings. Failure to acknowledge will lead to inappropriate treatment and harm to the patients. There were cases of unnecessary surgical procedures and chemotherapy instituted to patients due to assay interference by human chorionic gonadotropin assays. In this case, it has led to excessive replacement of thyroxine hormone inducing clinical thyrotoxicosis, which can lead to cardiac arrhythmia or accelerated osteoporosis. Heterophilic antibodies to mouse antibodies, rheumatoid factors, and drug are among the common causes of TSH assay interference. Conclusion: It is important for clinician to recognize assay interference as a cause of deranged lab results. Communication among physicians and clinical pathologist is important to minimize this error. 2017-05 Conference or Workshop Item REM application/pdf en http://irep.iium.edu.my/58566/1/TSH%20assay%20interference.pdf application/pdf en http://irep.iium.edu.my/58566/2/TAI%20poster%20ver%201.0.pdf Goh, Kian Guan and Zakaria, Miza Hiryanti and Shahar, Mohammad Arif and Omar, Ahmad Marzuki (2017) Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report. In: MEMS Annual COngress 2017, 19-21 May 2017, Kuala Lumpur. (Unpublished)
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
English
topic R Medicine (General)
RC Internal medicine
spellingShingle R Medicine (General)
RC Internal medicine
Goh, Kian Guan
Zakaria, Miza Hiryanti
Shahar, Mohammad Arif
Omar, Ahmad Marzuki
Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
description Background: Thyroid hormone assay interference is often misdiagnosed. Is has deep impact onto patient’s care as wrong interpretation of the results leads to wrong intervention. This case is to highlight the importance of recognizing immunoassay interference for thyroid stimulating-hormone (TSH) congenital hypothyroidism. Case report: the patient is a 22-year-old university student with congenital hypothyroidism, diagnosed at age 10 due to poor growth velocity and constipation. Sha was put on L-thyroxine replacement since diagnosis. Despite small body habitus (weight 42 kg and height 153,5 cm) she was on 1125 mcg of L-thyroxine per week (3.83 mcg/kg/day) due to persistently high TSH (8.558 uIU/mL) despite normal free T4 (19.47 pmol/L) and clinically euthyroid. There were episodes of iatrogenic hyperthyroidism due to over-replacement of L-thyroxine (free T4 48.96 pmol/L) and patient became thyrotoxic clinically. There were wide fluctuations of TSH reading (1.086 – 99.076 uIU/mL) despite normal free T4 values (10.66 – 17.1 pmol/L) and normal free T3 (4.6 pmol/L). Her thyroid function was repeated in different labs and showed relatively normal thyroid function (free T4 15.7 pmol/L and TSH 0.76 uIU/mL). Discussion: Thyroid hormone assay interference is a recognized entity in clinical laboratory settings. Failure to acknowledge will lead to inappropriate treatment and harm to the patients. There were cases of unnecessary surgical procedures and chemotherapy instituted to patients due to assay interference by human chorionic gonadotropin assays. In this case, it has led to excessive replacement of thyroxine hormone inducing clinical thyrotoxicosis, which can lead to cardiac arrhythmia or accelerated osteoporosis. Heterophilic antibodies to mouse antibodies, rheumatoid factors, and drug are among the common causes of TSH assay interference. Conclusion: It is important for clinician to recognize assay interference as a cause of deranged lab results. Communication among physicians and clinical pathologist is important to minimize this error.
format Conference or Workshop Item
author Goh, Kian Guan
Zakaria, Miza Hiryanti
Shahar, Mohammad Arif
Omar, Ahmad Marzuki
author_facet Goh, Kian Guan
Zakaria, Miza Hiryanti
Shahar, Mohammad Arif
Omar, Ahmad Marzuki
author_sort Goh, Kian Guan
title Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
title_short Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
title_full Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
title_fullStr Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
title_full_unstemmed Misleading thyroid-stimulating hormone results due to immunoassay interference: A case report
title_sort misleading thyroid-stimulating hormone results due to immunoassay interference: a case report
publishDate 2017
url http://irep.iium.edu.my/58566/1/TSH%20assay%20interference.pdf
http://irep.iium.edu.my/58566/2/TAI%20poster%20ver%201.0.pdf
http://irep.iium.edu.my/58566/
_version_ 1643615386004881408